Identificación de sistemas de primer y segundo orden mediante control basado en reset

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Identificación de sistemas de primer y segundo orden mediante control basado en reset

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Zaragoza, S. es_ES
dc.contributor.author Sanchez, J. es_ES
dc.contributor.author Baños, A. es_ES
dc.date.accessioned 2020-05-12T18:08:04Z
dc.date.available 2020-05-12T18:08:04Z
dc.date.issued 2020-04-07
dc.identifier.issn 1697-7912
dc.identifier.uri http://hdl.handle.net/10251/142981
dc.description.abstract [EN] The article presents a method for the identification of first and second order processes with time delay using reset controllers in the absence of disturbances. The method is based on compliance with the method of harmonic balance, which implies the use of an approximation of the control reset by its describing function. The FORE controller (First Order Reset Element) with fixed bandwidth has been chosen because it is the easiest reset driver that possesses all the inherent characteristics in this type of drivers and its descriptive function depends on the amplitude and frequency of its sinusoidal signal input. On the other hand, the fact that the behavior of this reset driver depends on of its reset band allows studying the impact of this parameter in the identification process and in its accuracy. es_ES
dc.description.abstract [ES] El artículo presenta un método para la identificación de plantas de primer y segundo orden con retardo usando controladores reseteados en ausencia de perturbaciones. El método se basa en el cumplimiento del principio de equilibrio armónico, lo que implica el uso de una aproximación del controlador reseteado mediante su función descriptiva. Para la realización de este trabajo se ha elegido el controlador FORE (First Order Reset Element) con banda de reset porque es el controlador reseteado que posee todas las características intrínsecas de este tipo de controladores y presenta una función descriptiva que depende de la amplitud y frecuencia de la señal sinusoidal de su entrada. Por otro lado, el que el comportamiento de este controlador dependa de la anchura de la banda de reset que se haya fijado permite estudiar el impacto de este parámetro en el proceso de identificación y en su precisión. es_ES
dc.description.sponsorship Este trabajo ha sido realizado parcialmente gracias al apoyo del Ministerio de Economía y Competitividad de España a través de los fondos asignados a los proyectos DPI2017-84259-C2-2-R y DPI2016-79278-C2-1-R. es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.relation.ispartof Revista Iberoamericana de Automática e Informática industrial es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Non-linear control systems es_ES
dc.subject Reset control es_ES
dc.subject System identification and parameters estimation es_ES
dc.subject Closed-loop identification es_ES
dc.subject Sistemas de control no lineal es_ES
dc.subject Control basado en reset es_ES
dc.subject Identificación de sistemas y estimación de parámetros es_ES
dc.subject Identificación en bucle cerrado es_ES
dc.title Identificación de sistemas de primer y segundo orden mediante control basado en reset es_ES
dc.title.alternative Identification of first and second order systems by reset control es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.4995/riai.2020.11598
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-84259-C2-2-R/ES/MODELADO Y CONTROL DEL PROCESO COMBINADO DE PRODUCCION DE MICROALGAS Y TRATAMIENTO DE AGUAS RESIDUALES CON REACTORES INDUSTRIALES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//DPI2016-79278-C2-1-R/ES/SISTEMAS DE CONTROL HIBRIDOS: APLICACIONES EN CONTROL DE PROCESOS Y CONTROL VEHICULAR/ es_ES
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Zaragoza, S.; Sanchez, J.; Baños, A. (2020). Identificación de sistemas de primer y segundo orden mediante control basado en reset. Revista Iberoamericana de Automática e Informática industrial. 17(2):116-129. https://doi.org/10.4995/riai.2020.11598 es_ES
dc.description.accrualMethod OJS es_ES
dc.relation.publisherversion https://doi.org/10.4995/riai.2020.11598 es_ES
dc.description.upvformatpinicio 116 es_ES
dc.description.upvformatpfin 129 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 17 es_ES
dc.description.issue 2 es_ES
dc.identifier.eissn 1697-7920
dc.relation.pasarela OJS\11598 es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.description.references Bajarangbali, R., Majhi, S., Pandey, S., 2014. Identification of FOPDT and SOPDT Process Dynamics Using Closed Loop Test. ISA Trans. 53, 1223-1231. https://doi.org/10.1016/j.isatra.2014.05.014 es_ES
dc.description.references Bajarangbali, R., Majhi, S., 2017. Estimation of First and Second Order Systems. Proc. Natl. Acad. Sci., India, Sect. A Phys. Sci. https://doi.org/10.1007/s40010-017-0357-6 es_ES
dc.description.references Baños, A., Dormido, S., Barreiro, A., 2011. Limit Cycles Analysis of reset control systems with reset band. Nonlinear Analysis: Hybrid Systems, 5, 163-173. https://doi.org/10.1016/j.nahs.2010.07.004 es_ES
dc.description.references Baños, A., Barreiro, A., 2012a, Reset Control Systems, Springer, London, 2012. https://doi.org/10.1007/978-1-4471-2250-0 es_ES
dc.description.references Barreiro A., Baños, A., 2012b. Sistemas de Control Basados en Reset. RIAI 9, 329-346. https://doi.org/10.1016/j.riai.2012.09.007 es_ES
dc.description.references Baños, A., Vidal, A. , 2012. Design of Reset Control Systems: the PI+CI Compensator. Journal of Dynamic Systems, Measurement, and Control, 134. https://doi.org/10.1115/1.4004773 es_ES
dc.description.references Beschi, M., Dormido, S., Sánchez, J., Visioli, A., Yebra, L. J., 2014. Event-based PI plus Feedforward Control Strategies for a Distributed Solar Collector Field. IEEE Trans. Control Syst. Technol. 22, 1615-1622. https://doi.org/10.1109/TCST.2013.2279216 es_ES
dc.description.references Beschi, M., Dormido, S., Sánchez, J., Visioli, A., 2015a. Closed-Loop Automatic Tuning Technique for an Event-Based PI Controller. Ind. Eng. Chem. Res. 54, 6362-6370. https://doi.org/10.1021/acs.iecr.5b01024 es_ES
dc.description.references Beschi, M., Dormido, S., Sánchez, J., Visioli, A., 2015b. An Event-based PI Controller Autotuning Technique for Integral Processes. Proceedings of the 1st IEEE International Conference on Event-Based Control, Communication, and Signal Processing; Krakow, Poland. https://doi.org/10.1109/EBCCSP.2015.7300684 es_ES
dc.description.references Chang, R.C., Shen, S.H., Yu, C.C., 1992. Derivation of Transfer Function from Relay Feedback Systems. Ind. Eng. Chem. Res. 31, 855-860. https://doi.org/10.1021/ie00003a030 es_ES
dc.description.references Clegg, J.C., 1958. A Nonlinear Integrator for Servomechanisms. Trans A.I.E.E. 77, 41-42. https://doi.org/10.1109/TAI.1958.6367399 es_ES
dc.description.references Davo, M.A., 2015. Análisis y Diseño de Sistemas de Control Reseteados. Tesis Doctoral. Universidad de Murcia. http://hdl.handle.net/10201/46666 es_ES
dc.description.references Friman, M., Waller, K.V., 1997. A Two-Channel Relay for Autotunning. Ind. Eng. Chem. Res. 36, 2662-2671. https://doi.org/10.1021/ie970013u es_ES
dc.description.references Gelb, A., Van der Velde, W. E., 1968. Multiple-Input Describing Functions and Nonlinear System Design. McGraw-Hill, New York, NY. es_ES
dc.description.references Gu, D., Ou, L., Wang, P., Zhang, W., 2006. Relay Feedback Autotuning Method for Integrating Processes with Inverse Response and Time Delay. Ind. Eng. Chem. Res. 45, 3119-3132. https://doi.org/10.1021/ie050739n es_ES
dc.description.references Ho, W.K., Feng, E.B., Gan, O.P., 1996. A Novel Relay Auto-Tuning Technique for Processes with Integration. Control Eng. Prac. 4, 923-928. https://doi.org/10.1016/0967-0661(96)00090-1 es_ES
dc.description.references Horowitz, I.M., Rosenbaum, P., 1975. Nonlinear Design for Cost of Feedback Reduction in Systems with Large Parameter Uncertainty. Int. J. Control 24, 977-1001. https://doi.org/10.1080/00207177508922051 es_ES
dc.description.references Kaya, I., 2006. Parameter Estimation for Integrating Processes Using Relay Feedback Control under Static Load Disturbances. Ind. Eng. Chem. Res. 45, 4726-4731. https://doi.org/10.1021/ie060270b es_ES
dc.description.references Khalil, H. K., 2002. Nonlinear Systems, Prentice Hall, NJ. es_ES
dc.description.references Li, W., Eskinat, E., Luyben, W.L., 1991. An Improved Autotune Identification Method. Ind. Eng. Chem. Res. 30, 1530-41. https://doi.org/10.1021/ie00055a019 es_ES
dc.description.references Liu, T., Wang, Q.G., Huang, H.P., 2013. A Tutorial Review on Process Identification from Step to Relay Feedback Test, J. Process Control, 23, 1597-1623. https://doi.org/10.1016/j.jprocont.2013.08.003 es_ES
dc.description.references Liu T, Gao F., 2012. Industrial Process Identification and Control: Design Step-Test and Relay-Experiment-based Methods. Springer-Verlag. London, UK. es_ES
dc.description.references Luyben, W. L., 1987. Derivation of Transfer Functions for Highly Nonlinear Distillation Columns. Ind. Eng. Chem. Res. 26, 2490-2495. https://doi.org/10.1021/ie00072a017 es_ES
dc.description.references Sánchez, J., Guinaldo, M., Visioli, A., Dormido, S., 2018a. Identification of Process Transfer Function Parameters in Event-based PI Control Loops. ISA Trans. 75, 157-171. https://doi.org/10.1016/j.isatra.2018.01.033 es_ES
dc.description.references Sánchez, J., Guinaldo, M., Visioli, A., Dormido, S., 2018b. Enhanced Event-based Identification Procedure for Process Control. Ind. Eng. Chem. Res. 57, 7218-7231. https://doi.org/10.1021/acs.iecr.7b05239 es_ES
dc.description.references Scali, C., Marchetti, G., Semino, D, 1999. Relay with Additional Delay for Identification and Autotuning of Completely Unknown Processes. Ind. Eng. Chem. Res. 38, 1987-1997. https://doi.org/10.1021/ie980616l es_ES
dc.description.references Shen, S.H., Wu, J.S., Yu, C.C., 1996. Use of Biased-Relay Feedback for System Identification. AIChE J. 42, 1174-1180. https://doi.org/10.1002/aic.690420431 es_ES
dc.description.references Slotine, J.J., Li, W., 1991. Applied Nonlinear Control. Prentice Hall, Englewood Cliffs, NJ. es_ES
dc.description.references Srinivasan, K., Chidambaram, M., 2003. Modified Relay Feedback Method for Improved System Identification. Comput. Chem. Eng. 27, 727-732. https://doi.org/10.1016/S0098-1354(02)00257-0 es_ES
dc.description.references Wang, P., Gu, D., Zhang, W., 2007. Modified Relay Feedback Identification Based on Describing Function Analysis. Ind. Eng. Chem. Res. 46, 1538-1546. https://doi.org/10.1021/ie061141y es_ES
dc.description.references Zaragoza, N., 2018. Identificación de Plantas Estables en Lazo Cerrado mediante Controladores Reseteados de Banda Fija. Trabajo Fin de Máster Ingeniería de Sistemas y Control. UNED, Madrid. es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem