dc.contributor.author | Miranda, Homero | es_ES |
dc.contributor.author | Cárdenas, Víctor | es_ES |
dc.contributor.author | Palacios, Elvia | es_ES |
dc.date.accessioned | 2020-06-05T14:45:17Z | |
dc.date.available | 2020-06-05T14:45:17Z | |
dc.date.issued | 2008-07-09 | |
dc.identifier.issn | 1697-7912 | |
dc.identifier.uri | http://hdl.handle.net/10251/145494 | |
dc.description.abstract | [EN] An alternative to regulate the DC bus capacitors voltage from shunt active power filter is presented in this paper. The power stage of shunt active power filter is a cascaded five-level inverter. This multilevel converter has two H power cells in series connection and each power cell has a capacitive link. With only one voltage measurement from one power cell, the control law proposed has to regulate the two DC link voltages. To accomplish the DC bus regulation and the current output tracking, PIs controllers are used on each control loop. In order to demonstrate and validate the effectiveness proposed in this work several mathematical analyses, simulations and experimental results are shown. | es_ES |
dc.description.abstract | [ES] En este artículo se explora un método para regular las tensiones en los buses de CC en un filtro activo de corriente. El inversor es un convertidor multinivel de cinco niveles y está formado por dos celdas en configuración puente H con enlace capacitivo. Mediante la medición del bus de CC de una celda, se controla la tensión en la otra reduciendo así el número de sensores de tensión. Para llevar a cabo la regulación del bus de CC y la corriente de salida, se utiliza un controlador PI para cada lazo de control. Se presentan una serie de análisis, simulaciones y resultados experimentales del sistema de potencia con el fin de validar la propuesta de este trabajo. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.relation.ispartof | Revista Iberoamericana de Automática e Informática industrial | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Fault Active filter | es_ES |
dc.subject | Inverter | es_ES |
dc.subject | Harmonics | es_ES |
dc.subject | Reactive power | es_ES |
dc.subject | PI controller | es_ES |
dc.subject | Filtro Activo | es_ES |
dc.subject | Inversores | es_ES |
dc.subject | Armónicos | es_ES |
dc.subject | Potencia reactiva | es_ES |
dc.subject | Controlador PI | es_ES |
dc.title | Una Alternativa para Regular los Buses de CC en un Filtro Activo Paralelo con Inversor de 5 Niveles en Cascada | es_ES |
dc.title.alternative | An alternative to regulate the Dc bus capacitors voltage from shunt active power filter based on 5-level cascaded inverter | es_ES |
dc.type | Artículo | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Miranda, H.; Cárdenas, V.; Palacios, E. (2008). Una Alternativa para Regular los Buses de CC en un Filtro Activo Paralelo con Inversor de 5 Niveles en Cascada. Revista Iberoamericana de Automática e Informática industrial. 5(3):29-36. http://hdl.handle.net/10251/145494 | es_ES |
dc.description.accrualMethod | OJS | es_ES |
dc.relation.publisherversion | https://polipapers.upv.es/index.php/RIAI/article/view/8292 | es_ES |
dc.description.upvformatpinicio | 29 | es_ES |
dc.description.upvformatpfin | 36 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 5 | es_ES |
dc.description.issue | 3 | es_ES |
dc.identifier.eissn | 1697-7920 | |
dc.relation.pasarela | OJS\8292 | es_ES |