Electro-Hydraulic Transient Regimes in Isolated Pumps Working as Turbines with Self-Excited Induction Generators

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Electro-Hydraulic Transient Regimes in Isolated Pumps Working as Turbines with Self-Excited Induction Generators

Mostrar el registro completo del ítem

Madeira, FC.; Fernandes, JFP.; Pérez-Sánchez, M.; López Jiménez, PA.; Ramos, HM.; Costa Branco, PJ. (2020). Electro-Hydraulic Transient Regimes in Isolated Pumps Working as Turbines with Self-Excited Induction Generators. Energies. 13(17):1-23. https://doi.org/10.3390/en13174521

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/157283

Ficheros en el ítem

Metadatos del ítem

Título: Electro-Hydraulic Transient Regimes in Isolated Pumps Working as Turbines with Self-Excited Induction Generators
Autor: Madeira, Filipe C. Fernandes, Joao F. P. Pérez-Sánchez, Modesto López Jiménez, Petra Amparo Ramos, Helena M. Costa Branco, P. J.
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient
Fecha difusión:
Resumen:
[EN] The use of pumps working as turbines (PATs) is a sustainable technical measure that contributes to the improvement of energy efficiency in water systems. However, its performance analysis in off-grid recovery systems ...[+]
Palabras clave: Pump working as turbine (PAT) , Self-excited induction generator (SEIG) , Transient behavior
Derechos de uso: Reconocimiento (by)
Fuente:
Energies. (eissn: 1996-1073 )
DOI: 10.3390/en13174521
Editorial:
MDPI AG
Versión del editor: https://doi.org/10.3390/en13174521
Código del Proyecto:
info:eu-repo/grantAgreement/Interreg//EAPA_198%2F2016/
Agradecimientos:
This research received some support from the project REDAWN (Reducing Energy Dependency in Atlantic Area Water Networks) EAPA_198/2016 from INTERREG ATLANTIC AREA.
Tipo: Artículo

References

Postacchini, M., Darvini, G., Finizio, F., Pelagalli, L., Soldini, L., & Di Giuseppe, E. (2020). Hydropower Generation Through Pump as Turbine: Experimental Study and Potential Application to Small-Scale WDN. Water, 12(4), 958. doi:10.3390/w12040958

Capelo, B., Pérez-Sánchez, M., Fernandes, J. F. P., Ramos, H. M., López-Jiménez, P. A., & Branco, P. J. C. (2017). Electrical behaviour of the pump working as turbine in off grid operation. Applied Energy, 208, 302-311. doi:10.1016/j.apenergy.2017.10.039

Fecarotta, O., Aricò, C., Carravetta, A., Martino, R., & Ramos, H. M. (2014). Hydropower Potential in Water Distribution Networks: Pressure Control by PATs. Water Resources Management, 29(3), 699-714. doi:10.1007/s11269-014-0836-3 [+]
Postacchini, M., Darvini, G., Finizio, F., Pelagalli, L., Soldini, L., & Di Giuseppe, E. (2020). Hydropower Generation Through Pump as Turbine: Experimental Study and Potential Application to Small-Scale WDN. Water, 12(4), 958. doi:10.3390/w12040958

Capelo, B., Pérez-Sánchez, M., Fernandes, J. F. P., Ramos, H. M., López-Jiménez, P. A., & Branco, P. J. C. (2017). Electrical behaviour of the pump working as turbine in off grid operation. Applied Energy, 208, 302-311. doi:10.1016/j.apenergy.2017.10.039

Fecarotta, O., Aricò, C., Carravetta, A., Martino, R., & Ramos, H. M. (2014). Hydropower Potential in Water Distribution Networks: Pressure Control by PATs. Water Resources Management, 29(3), 699-714. doi:10.1007/s11269-014-0836-3

Ramos, H., & Borga, A. (1999). Pumps as turbines: an unconventional solution to energy production. Urban Water, 1(3), 261-263. doi:10.1016/s1462-0758(00)00016-9

Fernandes, J. F. P., Pérez-Sánchez, M., da Silva, F. F., López-Jiménez, P. A., Ramos, H. M., & Branco, P. J. C. (2019). Optimal energy efficiency of isolated PAT systems by SEIG excitation tuning. Energy Conversion and Management, 183, 391-405. doi:10.1016/j.enconman.2019.01.016

Yi, Y., Zhang, Z., Chen, D., Zhou, R., Patelli, E., & Tolo, S. (2017). State feedback predictive control for nonlinear hydro-turbine governing system. Journal of Vibration and Control, 107754631774001. doi:10.1177/1077546317740013

Khan, M. F., & Khan, M. R. (2016). Analysis of voltage build-up and speed disturbance ride through capability of a self-excited induction generator for renewable energy application. International Journal of Power and Energy Conversion, 7(2), 157. doi:10.1504/ijpec.2016.076521

Han, Y., & Tan, L. (2020). Dynamic mode decomposition and reconstruction of tip leakage vortex in a mixed flow pump as turbine at pump mode. Renewable Energy, 155, 725-734. doi:10.1016/j.renene.2020.03.142

Pérez-Sánchez, M., Sánchez-Romero, F. J., López-Jiménez, P. A., & Ramos, H. M. (2018). PATs selection towards sustainability in irrigation networks: Simulated annealing as a water management tool. Renewable Energy, 116, 234-249. doi:10.1016/j.renene.2017.09.060

Pérez-Sánchez, M., López-Jiménez, P., & Ramos, H. (2018). PATs Operating in Water Networks under Unsteady Flow Conditions: Control Valve Manoeuvre and Overspeed Effect. Water, 10(4), 529. doi:10.3390/w10040529

[-]

recommendations

 