- -

Exploring TOF Capabilities of PET Detector Blocks Based on Large Monolithic Crystals and Analog SiPMs

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Exploring TOF Capabilities of PET Detector Blocks Based on Large Monolithic Crystals and Analog SiPMs

Mostrar el registro completo del ítem

Lamprou, E.; González Martínez, AJ.; Sánchez Martínez, F.; Benlloch Baviera, JM. (2020). Exploring TOF Capabilities of PET Detector Blocks Based on Large Monolithic Crystals and Analog SiPMs. Physica Medica. 70:10-18. https://doi.org/10.1016/j.ejmp.2019.12.004

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/162357

Ficheros en el ítem

Metadatos del ítem

Título: Exploring TOF Capabilities of PET Detector Blocks Based on Large Monolithic Crystals and Analog SiPMs
Autor: Lamprou, Efthymios González Martínez, Antonio Javier Sánchez Martínez, Filomeno Benlloch Baviera, Jose María
Entidad UPV: Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes
Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Fecha difusión:
Resumen:
[EN] Monolithic scintillators are more frequently used in PET instrumentation due to their advantages in terms of accurate position estimation of the impinging gamma rays both planar and depth of interaction, their increased ...[+]
Palabras clave: TOF-PET , Monolithic crystal , ASIC , SiPMs
Derechos de uso: Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
Fuente:
Physica Medica. (issn: 1120-1797 )
DOI: 10.1016/j.ejmp.2019.12.004
Editorial:
Elsevier
Versión del editor: https://doi.org/10.1016/j.ejmp.2019.12.004
Código del Proyecto:
info:eu-repo/grantAgreement/MINECO//TEC2016-79884-C2-1-R/ES/DESARROLLO DEL HARDWARE PARA SISTEMA DE DIAGNOSTICO POR IMAGEN MOLECULAR PARA CORAZON EN CONDICIONES DE ESTRES/
info:eu-repo/grantAgreement/EC/H2020/695536/EU/Innovative PET scanner for dynamic imaging/
Agradecimientos:
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the Spanish ...[+]
Tipo: Artículo

References

Surti, S. (2014). Update on Time-of-Flight PET Imaging. Journal of Nuclear Medicine, 56(1), 98-105. doi:10.2967/jnumed.114.145029

Spanoudaki, V. C., & Levin, C. S. (2010). Photo-Detectors for Time of Flight Positron Emission Tomography (ToF-PET). Sensors, 10(11), 10484-10505. doi:10.3390/s101110484

Szczesniak, T., Moszynski, M., Swiderski, L., Nassalski, A., Lavoute, P., & Kapusta, M. (2009). Fast Photomultipliers for TOF PET. IEEE Transactions on Nuclear Science, 56(1), 173-181. doi:10.1109/tns.2008.2008992 [+]
Surti, S. (2014). Update on Time-of-Flight PET Imaging. Journal of Nuclear Medicine, 56(1), 98-105. doi:10.2967/jnumed.114.145029

Spanoudaki, V. C., & Levin, C. S. (2010). Photo-Detectors for Time of Flight Positron Emission Tomography (ToF-PET). Sensors, 10(11), 10484-10505. doi:10.3390/s101110484

Szczesniak, T., Moszynski, M., Swiderski, L., Nassalski, A., Lavoute, P., & Kapusta, M. (2009). Fast Photomultipliers for TOF PET. IEEE Transactions on Nuclear Science, 56(1), 173-181. doi:10.1109/tns.2008.2008992

Renker, D. (2007). New trends on photodetectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 571(1-2), 1-6. doi:10.1016/j.nima.2006.10.016

Kim, C. L., Wang, G.-C., & Dolinsky, S. (2009). Multi-Pixel Photon Counters for TOF PET Detector and Its Challenges. IEEE Transactions on Nuclear Science, 56(5), 2580-2585. doi:10.1109/tns.2009.2028075

Moses, W. W. (2002). Current trends in scintillator detectors and materials. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 487(1-2), 123-128. doi:10.1016/s0168-9002(02)00955-5

Gundacker, S., Auffray, E., Pauwels, K., & Lecoq, P. (2016). Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET. Physics in Medicine and Biology, 61(7), 2802-2837. doi:10.1088/0031-9155/61/7/2802

Gundacker, S., Acerbi, F., Auffray, E., Ferri, A., Gola, A., Nemallapudi, M. V., … Lecoq, P. (2016). State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs. Journal of Instrumentation, 11(08), P08008-P08008. doi:10.1088/1748-0221/11/08/p08008

Surti, S., & Karp, J. S. (2016). Advances in time-of-flight PET. Physica Medica, 32(1), 12-22. doi:10.1016/j.ejmp.2015.12.007

Gundacker, S., Knapitsch, A., Auffray, E., Jarron, P., Meyer, T., & Lecoq, P. (2014). Time resolution deterioration with increasing crystal length in a TOF-PET system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 737, 92-100. doi:10.1016/j.nima.2013.11.025

Marcinkowski, R., España, S., Van Holen, R., & Vandenberghe, S. (2014). Optimized light sharing for high-resolution TOF PET detector based on digital silicon photomultipliers. Physics in Medicine and Biology, 59(23), 7125-7139. doi:10.1088/0031-9155/59/23/7125

González-Montoro, A., Sánchez, F., Martí, R., Hernández, L., Aguilar, A., Barberá, J., … González, A. J. (2018). Detector block performance based on a monolithic LYSO crystal using a novel signal multiplexing method. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 912, 372-377. doi:10.1016/j.nima.2017.10.098

Xi, D., Xie, Q., Zhu, J., Lin, L., Niu, M., Xiao, P., … Kao, C.-M. (2012). Optimization of the SiPM Pixel Size for a Monolithic PET Detector. Physics Procedia, 37, 1497-1503. doi:10.1016/j.phpro.2012.04.101

Gonzalez-Montoro A, Aguilar A, Canizares G, Conde P, Hernandez L, Vidal LF, et al. Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers. IEEE Trans Rad Plasma Med Sci. PP. 1-1. DOI: 10.1109/TRPMS.2017.2692819.

Krishnamoorthy, S., Blankemeyer, E., Mollet, P., Surti, S., Van Holen, R., & Karp, J. S. (2018). Performance evaluation of the MOLECUBES β-CUBE—a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors. Physics in Medicine & Biology, 63(15), 155013. doi:10.1088/1361-6560/aacec3

González-Montoro, A., Sánchez, F., Bruyndonckx, P., Cañizares, G., Benlloch, J. M., & González, A. J. (2019). Novel method to measure the intrinsic spatial resolution in PET detectors based on monolithic crystals. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 920, 58-67. doi:10.1016/j.nima.2018.12.056

Van Dam, H. T., Borghi, G., Seifert, S., & Schaart, D. R. (2013). Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimation. Physics in Medicine and Biology, 58(10), 3243-3257. doi:10.1088/0031-9155/58/10/3243

Di Francesco A, Bugalho R, Oliveira L, Pacher L, Rivetti A, Rolo M, et al. TOFPET2: A high-performance ASIC for time and amplitude measurements of SiPM signals in time-of-flight applications. Journal of Instrumentation, vol. 11, no. 03, p. C03042.

TOFPET2 ASIC Evaluation kit - Hardware User Guide (v1.2), v1.2, PETsys Electronics SA., 2018.

Lamprou, E., Aguilar, A., González-Montoro, A., Monzó, J. M., Cañizares, G., Iranzo, S., … Benlloch, J. M. (2018). PET detector block with accurate 4D capabilities. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 912, 132-136. doi:10.1016/j.nima.2017.11.002

Acerbi, F., & Gundacker, S. (2019). Understanding and simulating SiPMs. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 926, 16-35. doi:10.1016/j.nima.2018.11.118

Schug D, Nadig V, Weissler B, Gebhardt P, Schulz V. Initial Measurements with the PETsys TOFPET2 ASIC Evaluation Kit and a Characterization of the ASIC TDC IEEE Trans Rad Plasma Med Sci. PP. 1-1. DOI: 10.1109/TRPMS.2018.2884564.

Seifert, S., van Dam, H. T., Vinke, R., Dendooven, P., Lohner, H., Beekman, F. J., & Schaart, D. R. (2012). A Comprehensive Model to Predict the Timing Resolution of SiPM-Based Scintillation Detectors: Theory and Experimental Validation. IEEE Transactions on Nuclear Science, 59(1), 190-204. doi:10.1109/tns.2011.2179314

Vinke R, Olcott PD, Cates JW, Levin CS. The lower timing resolution bound for scintillators with non-negligible optical photon transport time in time-of-flight PET. Phys. Med. Phys. Med. Biol. 59 6215. Phys Med Biol. 2014; 59(20): 6215–29.

Gonzalez AJ, Sanchez F, Benlloch JM. 2018 Organ-Dedicated Molecular Imaging Systems. IEEE Trans Ratiat Plasma Med Sci. 2017; 2(5): 388–403.

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem