Monte Carlo model of a BEGe detector to support gamma-spectrometry in an emergency response

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Monte Carlo model of a BEGe detector to support gamma-spectrometry in an emergency response

Mostrar el registro completo del ítem

Ordóñez, J.; Martorell Alsina, SS.; Gallardo Bermell, S.; Ortiz Moragón, J. (2020). Monte Carlo model of a BEGe detector to support gamma-spectrometry in an emergency response. Radiation Physics and Chemistry. 172:1-7. https://doi.org/10.1016/j.radphyschem.2020.108837

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/166749

Ficheros en el ítem

Metadatos del ítem

Título: Monte Carlo model of a BEGe detector to support gamma-spectrometry in an emergency response
Autor: Ordóñez, J. Martorell Alsina, Sebastián Salvador Gallardo Bermell, Sergio Ortiz Moragón, Josefina
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear
Fecha difusión:
Resumen:
[EN] One of the problems of measuring high radioactivity in an emergency scenario is the fact that the detector can become saturated or reach a measuring dead time too high to give reliable results, which means repeating ...[+]
Derechos de uso: Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
Fuente:
Radiation Physics and Chemistry. (issn: 0969-806X )
DOI: 10.1016/j.radphyschem.2020.108837
Editorial:
Elsevier
Versión del editor: https://doi.org/10.1016/j.radphyschem.2020.108837
Título del congreso: 3rd International Conference on Dosimetry and its Applications (ICDA-3)
Lugar del congreso: Lisbon, Portugal
Fecha congreso: Mayo 27-31,2019
Código del Proyecto:
info:eu-repo/grantAgreement/UPV//FPI-2015-S2-1576/
info:eu-repo/grantAgreement/Agencia Valenciana de Seguridad y Respuesta a las Emergencias//S7042000/
Agradecimientos:
The authors gratefully acknowledge the Catedra CSN-UPV Vicente Serradell, Spain as well as the Laboratorio de Radiactividad Ambiental (Universitat Politecnica de Valencia), Spain, for the dedicated funding and resources ...[+]
Tipo: Artículo Comunicación en congreso

References

Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., … Barrand, G. (2003). Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 506(3), 250-303. doi:10.1016/s0168-9002(03)01368-8

Blank, B., Souin, J., Ascher, P., Audirac, L., Canchel, G., Gerbaux, M., … Thomas, J. C. (2015). High-precision efficiency calibration of a high-purity co-axial germanium detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 776, 34-44. doi:10.1016/j.nima.2014.12.071

Chham, E., García, F. P., El Bardouni, T., Ferro-García, M. A., Azahra, M., Benaalilou, K., … Kaddour, M. (2015). Monte Carlo analysis of the influence of germanium dead layer thickness on the HPGe gamma detector experimental efficiency measured by use of extended sources. Applied Radiation and Isotopes, 95, 30-35. doi:10.1016/j.apradiso.2014.09.007 [+]
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., … Barrand, G. (2003). Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 506(3), 250-303. doi:10.1016/s0168-9002(03)01368-8

Blank, B., Souin, J., Ascher, P., Audirac, L., Canchel, G., Gerbaux, M., … Thomas, J. C. (2015). High-precision efficiency calibration of a high-purity co-axial germanium detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 776, 34-44. doi:10.1016/j.nima.2014.12.071

Chham, E., García, F. P., El Bardouni, T., Ferro-García, M. A., Azahra, M., Benaalilou, K., … Kaddour, M. (2015). Monte Carlo analysis of the influence of germanium dead layer thickness on the HPGe gamma detector experimental efficiency measured by use of extended sources. Applied Radiation and Isotopes, 95, 30-35. doi:10.1016/j.apradiso.2014.09.007

Croudace, I. W., Warwick, P. E., Reading, D. G., & Russell, B. C. (2016). Recent contributions to the rapid screening of radionuclides in emergency responses and nuclear forensics. TrAC Trends in Analytical Chemistry, 85, 120-129. doi:10.1016/j.trac.2016.05.007

Dababneh, S., Al-Nemri, E., & Sharaf, J. (2014). Application of Geant4 in routine close geometry gamma spectroscopy for environmental samples. Journal of Environmental Radioactivity, 134, 27-34. doi:10.1016/j.jenvrad.2014.02.019

Fonseca, T. C. F., Mendes, B. M., & Hunt, J. G. (2017). Simulation of internal contamination screening with dose rate meters. Radiation Physics and Chemistry, 140, 112-115. doi:10.1016/j.radphyschem.2017.03.047

Garcı́a-Talavera, M., Neder, H., Daza, M. J., & Quintana, B. (2000). Towards a proper modeling of detector and source characteristics in Monte Carlo simulations. Applied Radiation and Isotopes, 52(3), 777-783. doi:10.1016/s0969-8043(99)00244-4

Hernandez-Prieto, A., Quintana, B., Martìn, S., & Domingo-Pardo, C. (2016). Study of accuracy in the position determination with SALSA, a γ-scanning system for the characterization of segmented HPGe detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 823, 98-106. doi:10.1016/j.nima.2016.03.103

Hurtado, S., Garcı́a-León, M., & Garcı́a-Tenorio, R. (2004). GEANT4 code for simulation of a germanium gamma-ray detector and its application to efficiency calibration. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 518(3), 764-774. doi:10.1016/j.nima.2003.09.057

Jurado Vargas, M., & Guerra, A. L. (2006). Application of PENELOPE code to the efficiency calibration of coaxial germanium detectors. Applied Radiation and Isotopes, 64(10-11), 1319-1322. doi:10.1016/j.apradiso.2006.02.037

Maučec, M., de Meijer, R. J., Rigollet, C., Hendriks, P. H. G. M., & Jones, D. G. (2004). Detection of radioactive particles offshore by γ-ray spectrometry Part I: Monte Carlo assessment of detection depth limits. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 525(3), 593-609. doi:10.1016/j.nima.2004.01.074

Ródenas, J., Martinavarro, A., & Rius, V. (2000). Validation of the MCNP code for the simulation of Ge-detector calibration. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 450(1), 88-97. doi:10.1016/s0168-9002(00)00253-9

Ródenas, J., Gallardo, S., Ballester, S., Primault, V., & Ortiz, J. (2007). Application of the Monte Carlo method to the analysis of measurement geometries for the calibration of a HP Ge detector in an environmental radioactivity laboratory. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 263(1), 144-148. doi:10.1016/j.nimb.2007.04.210

Sima, O., Arnold, D., & Dovlete, C. (2001). Journal of Radioanalytical and Nuclear Chemistry, 248(2), 359-364. doi:10.1023/a:1010619806898

Vidmar, T., Aubineau-Laniece, I., Anagnostakis, M. J., Arnold, D., Brettner-Messler, R., Budjas, D., … Vidmar, G. (2008). An intercomparison of Monte Carlo codes used in gamma-ray spectrometry. Applied Radiation and Isotopes, 66(6-7), 764-768. doi:10.1016/j.apradiso.2008.02.015

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem