Mostrar el registro sencillo del ítem
dc.contributor.author | Bellido, P. | es_ES |
dc.contributor.author | Seimetz, Michael | es_ES |
dc.contributor.author | Soriano, A. | es_ES |
dc.contributor.author | Huertas, C. | es_ES |
dc.contributor.author | García Lopez, J. | es_ES |
dc.contributor.author | Jimenez-Ramos, M. C: | es_ES |
dc.contributor.author | Fernandez, B. | es_ES |
dc.contributor.author | Conde, P. | es_ES |
dc.contributor.author | Crespo, E. | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Hernández, L. | es_ES |
dc.contributor.author | Iborra, A. | es_ES |
dc.contributor.author | Martos, F. | es_ES |
dc.contributor.author | Moliner, L. | es_ES |
dc.contributor.author | Rigla, J. P. | es_ES |
dc.contributor.author | Rodríguez-Álvarez, M. J. | es_ES |
dc.contributor.author | Sánchez, F. | es_ES |
dc.contributor.author | Vidal San Sebastian, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.date.accessioned | 2021-06-02T06:59:41Z | |
dc.date.available | 2021-06-02T06:59:41Z | |
dc.date.issued | 2013-11-02 | es_ES |
dc.identifier.isbn | 978-1-4799-0534-8 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/167117 | |
dc.description.abstract | [Otros] When an ultra-intense and ultra-short laser pulse interacts with solid matter a fraction of the laser pulse can be converted into kinetic energy of a beam of charged particles. Radiochromic film (RCF), widely used as radiation detector in the field of conventional radiotherapy, can be used as detector for laser-accelerated protons. If used in stack configuration it is a useful and versatile tool to obtain 2D spatial distribution and energetic information of proton beams. In order to obtain dosimetric information from RCF it must be properly calibrated. Irradiating film pieces under well known conditions allows us to establish a relation between the optical density (OD) of the radiochromic film, which is measured through a flat bed scanner operating in transmission mode, and the deposited energy in the active layer. A calibration curve over a large dynamic range (3 orders of magnitude) has been obtained for few MeV protons. Our calibration process has been performed at the Spanish National Accelerator Center at Sevilla. We have irradiated several areas of a single RCF with a constant 50 pA beam current and fixed 4 MeV energy from a 3 MV tandem accelerator. We have calculated the deposited energy in the films under the same conditions. We demonstrate that this technique can be used to measure the spectrum and total energy of a laser-accelerated mixed-energy proton beam. This detector has been calibrated for a near future application at the Center of Pulsed, Ultra-short, Ultra-intense Lasers (CLPU) at Salamanca (Spain). We present the calibration procedure and results, the design optimization, and a comparison with similar experiments. | es_ES |
dc.description.sponsorship | Project funded by the Spanish Ministry of Economy and Competitiveness and co-funded with FEDERs funds within the INNPACTO 2011 program. This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e InnovacionTecnologica (I+D+i) under Grant No. FIS2010-21216-CO2-01 and the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | IEEE | es_ES |
dc.relation.ispartof | 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | Dosimetric Calibration of Radiochromic Film For Laser-accelerated Proton Beams | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.identifier.doi | 10.1109/NSSMIC.2013.6829806 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010/ES/Desarrollo de nuevas terapias para tumores cerebrales/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//ISIC2011%2F013/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes | es_ES |
dc.description.bibliographicCitation | Bellido, P.; Seimetz, M.; Soriano, A.; Huertas, C.; García Lopez, J.; Jimenez-Ramos, MC.; Fernandez, B.... (2013). Dosimetric Calibration of Radiochromic Film For Laser-accelerated Proton Beams. IEEE. 20-23. https://doi.org/10.1109/NSSMIC.2013.6829806 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors Workshop (2013 IEEE NSS/MIC/RTSD) | es_ES |
dc.relation.conferencedate | Octubre 27-Noviembre 02,2013 | es_ES |
dc.relation.conferenceplace | Seoul, Korea | es_ES |
dc.relation.publisherversion | https://doi.org/10.1109/NSSMIC.2013.6829806 | es_ES |
dc.description.upvformatpinicio | 20 | es_ES |
dc.description.upvformatpfin | 23 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.relation.pasarela | S\268537 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |