Aliverti A, Pedotti A (2002) Opto-electronic Plethysmography. In: Aliverti A, Brusasco V, Macklem PT, Pedotti A (eds) Mechanics of breathing. Springer, Milano, pp 47–59. https://doi.org/10.1007/978-88-470-2916-3_5
Aliverti A, Dellaca R, Pelosi P, Chiumello D, Pedotti A, Gattinoni L (2000) Optoelectronic plethysmography in intensive care patients. Am J Respir Crit Care Med 161:1546–1552. https://doi.org/10.1164/ajrccm.161.5.9903024
Aliverti A, Dellacà R, Pelosi P, Chiumello D, Gattinoni L, Pedotti A (2001) Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography. Ann Biomed Eng 29:60–70. https://doi.org/10.1114/1.1332084
[+]
Aliverti A, Pedotti A (2002) Opto-electronic Plethysmography. In: Aliverti A, Brusasco V, Macklem PT, Pedotti A (eds) Mechanics of breathing. Springer, Milano, pp 47–59. https://doi.org/10.1007/978-88-470-2916-3_5
Aliverti A, Dellaca R, Pelosi P, Chiumello D, Pedotti A, Gattinoni L (2000) Optoelectronic plethysmography in intensive care patients. Am J Respir Crit Care Med 161:1546–1552. https://doi.org/10.1164/ajrccm.161.5.9903024
Aliverti A, Dellacà R, Pelosi P, Chiumello D, Gattinoni L, Pedotti A (2001) Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography. Ann Biomed Eng 29:60–70. https://doi.org/10.1114/1.1332084
Aliverti A, Stevenson N, Dellaca R, Mauro AL, Pedotti A, Calverley P (2004) Regional chest wall volumes during exercise in chronic obstructive pulmonary disease. Thorax 59:210–216. https://doi.org/10.1136/thorax.2003.011494
Aliverti A, Uva B, Laviola M, Bovio D, Mauro AL, Tarperi C, Colombo E, Loomas B, Pedotti A, Similowski T (2010) Concomitant ventilatory and circulatory functions of the diaphragm and abdominal muscles. J Appl Physiol 109:1432–1440. https://doi.org/10.1152/japplphysiol.00576.2010
Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. Statistician:307–317
Bates A, Ling MJ, Mann J, DK Arvind 2010 Respiratory rate and flow waveform estimation from tri-axial accelerometer data. 2010 International Conference on Body Sensor Networks. IEEE:144–150. DOI: https://doi.org/10.1109/BSN.2010.50
Bergese SD, Mestek ML, Kelley SD, McIntyre R Jr, Uribe AA, Sethi R, Watson JN, Addison PS (2017) Multicenter study validating accuracy of a continuous respiratory rate measurement derived from pulse oximetry: a comparison with capnography. Anesth Analg 124:1153–1159. https://doi.org/10.1213/ANE.0000000000001852
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310
Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160. https://doi.org/10.1177/096228029900800204
Breteler MJ, Huizinga E, van Loon K, Leenen LP, Dohmen DA, Kalkman CJ, Blokhuis TJ (2018) Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study. BMJ Open 8:e020162. https://doi.org/10.1136/bmjopen-2017-020162
Buch P, Friberg J, Scharling H, Lange P, Prescott E (2003) Reduced lung function and risk of atrial fibrillation in the Copenhagen City Heart Study. Eur Respir J 21:1012–1016. https://doi.org/10.1183/09031936.03.00051502
Castagna J, Weil MH, Shubin H (1974) Factors determining survival in patients with cardiac arrest. Chest 65:527–529. https://doi.org/10.1378/chest.65.5.527
Cesareo A, Previtali Y, Biffi E, Aliverti A (2019) Assessment of breathing parameters using an inertial measurement unit (IMU)-based system. Sensors 19:88. https://doi.org/10.3390/s19010088
Charlton PH, Bonnici T, Tarassenko L, Clifton DA, Beale R, Watkinson PJ (2016) An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram. Physiol Meas 37:610–626. https://doi.org/10.1088/0967-3334/37/4/610
Craig JJ (2009) Introduction to robotics: mechanics and control, 3/E. Pearson education international, 2005
Cretikos MA, Bellomo R, Hillman K, Chen J, Finfer S, Flabouris A (2008) Respiratory rate: the neglected vital sign. Med J Aust 188:657. https://doi.org/10.5694/j.1326-5377.2008.tb01825.x
Dingli K, Coleman EL, Vennelle M, Finch SP, Wraith PK, Mackay TW, Douglas NJ (2003) Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. Eur Respir J 21:253–259. https://doi.org/10.1183/09031936.03.00298103
Fekr AR, Janidarmian M, Radecka K, Zilic Z (2014) A medical cloud-based platform for respiration rate measurement and hierarchical classification of breath disorders. Sensors 14:11204–11224. https://doi.org/10.3390/s140611204
Fekr AR, Radecka K, Zilic Z (2014) Design of an E-health respiration and body posture monitoring system and its application for rib cage and abdomen synchrony analysis. IEEE Int Conf Bioinforma Bioeng:141–148. https://doi.org/10.1109/BIBE.2014.67
Fieselmann JF, Hendryx MS, Helms CM, Wakefield DS (1993) Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients. J Gen Intern Med 8:354–360. https://doi.org/10.1007/bf02600071
Gaidhani A, Moon KS, Ozturk Y, Lee SQ, Youm W (2017) Extraction and analysis of respiratory motion using wearable inertial sensor system during trunk motion. Sensors 17:2932. https://doi.org/10.3390/s17122932
Gollee H, Chen W (2007) Real-time detection of respiratory activity using an inertial measurement unit. Conf Proc IEEE Eng Med Biol Soc 2007:2230–2233. https://doi.org/10.1109/IEMBS.2007.4352768
Hung DP, Bonnet S, Guillemaud R, Castelli E, Pham Thi NY (2008, 2008) Estimation of respiratory waveform using an accelerometer. Conf Proc IEEE Eng Med Biol Soc:1493–1496. https://doi.org/10.1109/IEMBS.2008.4650316
Iandelli I, Aliverti A, Kayser B, Dellacà R, Cala SJ, Duranti R, Kelly S, Scano G, Sliwinski P, Yan S (2002) Determinants of exercise performance in normal men with externally imposed expiratory flow limitation. J Appl Physiol 92:1943–1952. https://doi.org/10.1152/japplphysiol.00393.2000
Jin A, Yin B, Morren G, Duric H, Aarts RM (2009) Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living. Conf Proc IEEE Eng Med Biol Soc 2009:5677–5680. https://doi.org/10.1109/IEMBS.2009.5333116
Kenyon C, Cala S, Yan S, Aliverti A, Scano G, Duranti R, Pedotti A, Macklem PT (1997) Rib cage mechanics during quiet breathing and exercise in humans. J Appl Physiol 83:1242–1255. https://doi.org/10.1152/jappl.1997.83.4.1242
Konno K, Mead J (1967) Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol 22:407–422. https://doi.org/10.1152/jappl.1967.22.3.407
Kontaxis S, Lazaro J, Corino VD, Sandberg F, Bailón R, Laguna P, Sörnmo L (2019, 2019) ECG-derived respiratory rate in atrial fibrillation. IEEE Trans Biomed Eng. https://doi.org/10.1109/TBME.2019.2923587
Kuipers JB (1999) Quaternions and rotation sequences. Princeton university press Princeton
Lapi S, Lavorini F, Borgioli G, Calzolai M, Masotti L, Pistolesi M, Fontana GA (2014) Respiratory rate assessment using a dual-accelerometer device. Respir Physiol Neurobiol 191:60–66. https://doi.org/10.1016/j.resp.2013.11.003
Layton AM, Moran SL, Garber CE, Armstrong HF, Basner RC, Thomashow BM, Bartels MN (2013) Optoelectronic plethysmography compared to spirometry during maximal exercise. Respir Physiol Neurobiol 185:362–368. https://doi.org/10.1016/j.resp.2012.09.004
Liu G, Guo Y, Zhu Q, Huang B, Wang L (2011) Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemed J E Health 17:705–711. https://doi.org/10.1089/tmj.2011.0022
Madgwick SO, Harrison AJ, Vaidyanathan A (2011) Estimation of IMU and MARG orientation using a gradient descent algorithm. IEEE Int Conf Rehabil Robot 2011:1–7. https://doi.org/10.1109/ICORR.2011.5975346
Mann J, Rabinovich R, Bates A, Giavedoni S, MacNee W, Arvind DK (2011) Simultaneous activity and respiratory monitoring using an accelerometer. Int Conf Body Sens Netw 2011:139–143. https://doi.org/10.1109/BSN.2011.26
Marins JL, Yun X, Bachmann ER,. McGhee RB, Zyda MJ (2001) An extended Kalman filter for quaternion-based orientation estimation using MARG sensors. Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium. 2001: 2003-2011. DOI: https://doi.org/10.1109/IROS.2001.976367
McCaughey E, McLachlan A, Gollee H (2014) Non-intrusive real-time breathing pattern detection and classification for automatic abdominal functional electrical stimulation. Med Eng Phys 36:1057–1061. https://doi.org/10.1016/j.medengphy.2014.04.005
Moody GB, Mark RG, Bump MA, Weinstein JS, Berman AD, Mietus JE, Goldberger AL (1986) Clinical validation of the ECG-derived respiration (EDR) technique. Comput Cardiol 13:507–510
Kundan Nepal, Eric Biegeleisen and Ning T 2002 Apnea detection and respiration rate estimation through parametric modelling. Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342), 2002: 277-278.DOI: https://doi.org/10.1109/NEBC.2002.999573
Priori R, Aliverti A, Albuquerque AL, Quaranta M, Albert P, Calverley PM (2013) The effect of posture on asynchronous chest wall movement in COPD. J Appl Physiol 114:1066–1075. https://doi.org/10.1152/japplphysiol.00414.2012
Reinvuo T, Hannula M, Sorvoja H, Alasaarela E, Myllyla R (2006) Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor proceedings of the 2006 IEEE Sensors Applications Symposium, 2006: 192–195. DOI: https://doi.org/10.1109/SAS.2006.1634270
Selvaraj N (2014) Long-term remote monitoring of vital signs using a wireless patch sensor. IEEE Healthc Innov Conf (HIC) 2014:83–86. https://doi.org/10.1109/HIC.2014.7038880
Staats BA, Bonekat HW, Harris CD, Offord KP (1984) Chest wall motion in sleep apnea. Am Rev Respir Dis 130:59–63. https://doi.org/10.1164/arrd.1984.130.1.59
Stevenson IH, Teichtahl H, Cunnington D, Ciavarella S, Gordon I, Kalman JM (2008) Prevalence of sleep disordered breathing in paroxysmal and persistent atrial fibrillation patients with normal left ventricular function. Eur Heart J 29:1662–1669. https://doi.org/10.1093/eurheartj/ehn214
Storck K, Karlsson M, Ask P, Loyd D (1996) Heat transfer evaluation of the nasal thermistor technique. IEEE Trans Biomed Eng 43:1187–1191. https://doi.org/10.1109/10.544342
Subbe C, Davies R, Williams E, Rutherford P, Gemmell L (2003) Effect of introducing the modified early warning score on clinical outcomes, cardio-pulmonary arrests and intensive care utilisation in acute medical admissions. Anaesthesia 58:797–802. https://doi.org/10.1046/j.1365-2044.2003.03258.x
Terzano C, Romani S, Conti V, Paone G, Oriolo F, Vitarelli A (2014) Atrial fibrillation in the acute, hypercapnic exacerbations of COPD. Eur Rev Med Pharmacol Sci 18:2908–2917
Tobin MJ, Yang K (1990) Weaning from mechanical ventilation. Crit Care Clin 6:725–747
Torres A, Fiz JA, Galdiz B, Gea J, Morera J, Jané R (2004) Assessment of respiratory muscle effort studying diaphragm movement registered with surface sensors. Animal model (dogs). Conf Proc IEEE Eng Med Biol Soc 2004:3917–3920. https://doi.org/10.1109/IEMBS.2004.1404095
van Loon K, Peelen LM, van de Vlasakker EC, Kalkman CJ, van Wolfswinkel L, van Zaane B (2018) Accuracy of remote continuous respiratory rate monitoring technologies intended for low care clinical settings: a prospective observational study. Can J Anaesth 65:1324–1332. https://doi.org/10.1007/s12630-018-1214-z
Vieira DS, Hoffman M, Pereira DA, Britto RR, Parreira VF (2013) Optoelectronic plethysmography: intra-rater and inter-rater reliability in healthy subjects. Respir Physiol Neurobiol 189:473–476. https://doi.org/10.1016/j.resp.2013.08.023
Werthammer J, Krasner J, DiBenedetto J, Stark AR (1983) Apnea monitoring by acoustic detection of airflow. Pediatrics 71:53–55
Yadollahi A, Moussavi ZM (2006) A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans Biomed Eng 53:662–668. https://doi.org/10.1109/TBME.2006.870231
Yoon J, Noh Y, Kwon Y, Kim W, Yoon H (2014) Improvement of dynamic respiration monitoring through sensor fusion of accelerometer and gyro-sensor. J Electr Eng Technol 9:334–343. https://doi.org/10.5370/JEET.2014.9.1.334
[-]