- -

A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units

Mostrar el registro completo del ítem

Cesareo, A.; Biffi, E.; Cuesta Frau, D.; D'angelo, MG.; Aliverti, A. (2020). A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units. Medical & Biological Engineering & Computing. 58:785-804. https://doi.org/10.1007/s11517-020-02125-9

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/176071

Ficheros en el ítem

Metadatos del ítem

Título: A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units
Autor: Cesareo, Ambra Biffi, Emilia Cuesta Frau, David D'Angelo, Maria G. Aliverti, Andrea
Entidad UPV: Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors
Fecha difusión:
Resumen:
[EN] Continuous monitoring of breathing frequency (f(B)) could foster early prediction of adverse clinical effects and exacerbation of medical conditions. Current solutions are invasive or obtrusive and thus not suitable ...[+]
Palabras clave: Monitoring , Physiologic , Respiration , Wearable electronic devices , Mobile health units , Optoelectronic plethysmography
Derechos de uso: Cerrado
Fuente:
Medical & Biological Engineering & Computing. (issn: 0140-0118 )
DOI: 10.1007/s11517-020-02125-9
Editorial:
Springer-Verlag
Versión del editor: https://doi.org/10.1007/s11517-020-02125-9
Agradecimientos:
The authors thank "Fondazione per la Ricerca Scientifica Termale grants" for the financial support and all the participants. A special thanks to Davide Redaelli for the support in the realization of the housing boxes, from ...[+]
Tipo: Artículo

References

Aliverti A, Pedotti A (2002) Opto-electronic Plethysmography. In: Aliverti A, Brusasco V, Macklem PT, Pedotti A (eds) Mechanics of breathing. Springer, Milano, pp 47–59. https://doi.org/10.1007/978-88-470-2916-3_5

Aliverti A, Dellaca R, Pelosi P, Chiumello D, Pedotti A, Gattinoni L (2000) Optoelectronic plethysmography in intensive care patients. Am J Respir Crit Care Med 161:1546–1552. https://doi.org/10.1164/ajrccm.161.5.9903024

Aliverti A, Dellacà R, Pelosi P, Chiumello D, Gattinoni L, Pedotti A (2001) Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography. Ann Biomed Eng 29:60–70. https://doi.org/10.1114/1.1332084 [+]
Aliverti A, Pedotti A (2002) Opto-electronic Plethysmography. In: Aliverti A, Brusasco V, Macklem PT, Pedotti A (eds) Mechanics of breathing. Springer, Milano, pp 47–59. https://doi.org/10.1007/978-88-470-2916-3_5

Aliverti A, Dellaca R, Pelosi P, Chiumello D, Pedotti A, Gattinoni L (2000) Optoelectronic plethysmography in intensive care patients. Am J Respir Crit Care Med 161:1546–1552. https://doi.org/10.1164/ajrccm.161.5.9903024

Aliverti A, Dellacà R, Pelosi P, Chiumello D, Gattinoni L, Pedotti A (2001) Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography. Ann Biomed Eng 29:60–70. https://doi.org/10.1114/1.1332084

Aliverti A, Stevenson N, Dellaca R, Mauro AL, Pedotti A, Calverley P (2004) Regional chest wall volumes during exercise in chronic obstructive pulmonary disease. Thorax 59:210–216. https://doi.org/10.1136/thorax.2003.011494

Aliverti A, Uva B, Laviola M, Bovio D, Mauro AL, Tarperi C, Colombo E, Loomas B, Pedotti A, Similowski T (2010) Concomitant ventilatory and circulatory functions of the diaphragm and abdominal muscles. J Appl Physiol 109:1432–1440. https://doi.org/10.1152/japplphysiol.00576.2010

Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. Statistician:307–317

Bates A, Ling MJ, Mann J, DK Arvind 2010 Respiratory rate and flow waveform estimation from tri-axial accelerometer data. 2010 International Conference on Body Sensor Networks. IEEE:144–150. DOI: https://doi.org/10.1109/BSN.2010.50

Bergese SD, Mestek ML, Kelley SD, McIntyre R Jr, Uribe AA, Sethi R, Watson JN, Addison PS (2017) Multicenter study validating accuracy of a continuous respiratory rate measurement derived from pulse oximetry: a comparison with capnography. Anesth Analg 124:1153–1159. https://doi.org/10.1213/ANE.0000000000001852

Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310

Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160. https://doi.org/10.1177/096228029900800204

Breteler MJ, Huizinga E, van Loon K, Leenen LP, Dohmen DA, Kalkman CJ, Blokhuis TJ (2018) Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study. BMJ Open 8:e020162. https://doi.org/10.1136/bmjopen-2017-020162

Buch P, Friberg J, Scharling H, Lange P, Prescott E (2003) Reduced lung function and risk of atrial fibrillation in the Copenhagen City Heart Study. Eur Respir J 21:1012–1016. https://doi.org/10.1183/09031936.03.00051502

Castagna J, Weil MH, Shubin H (1974) Factors determining survival in patients with cardiac arrest. Chest 65:527–529. https://doi.org/10.1378/chest.65.5.527

Cesareo A, Previtali Y, Biffi E, Aliverti A (2019) Assessment of breathing parameters using an inertial measurement unit (IMU)-based system. Sensors 19:88. https://doi.org/10.3390/s19010088

Charlton PH, Bonnici T, Tarassenko L, Clifton DA, Beale R, Watkinson PJ (2016) An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram. Physiol Meas 37:610–626. https://doi.org/10.1088/0967-3334/37/4/610

Craig JJ (2009) Introduction to robotics: mechanics and control, 3/E. Pearson education international, 2005

Cretikos MA, Bellomo R, Hillman K, Chen J, Finfer S, Flabouris A (2008) Respiratory rate: the neglected vital sign. Med J Aust 188:657. https://doi.org/10.5694/j.1326-5377.2008.tb01825.x

Dingli K, Coleman EL, Vennelle M, Finch SP, Wraith PK, Mackay TW, Douglas NJ (2003) Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. Eur Respir J 21:253–259. https://doi.org/10.1183/09031936.03.00298103

Fekr AR, Janidarmian M, Radecka K, Zilic Z (2014) A medical cloud-based platform for respiration rate measurement and hierarchical classification of breath disorders. Sensors 14:11204–11224. https://doi.org/10.3390/s140611204

Fekr AR, Radecka K, Zilic Z (2014) Design of an E-health respiration and body posture monitoring system and its application for rib cage and abdomen synchrony analysis. IEEE Int Conf Bioinforma Bioeng:141–148. https://doi.org/10.1109/BIBE.2014.67

Fieselmann JF, Hendryx MS, Helms CM, Wakefield DS (1993) Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients. J Gen Intern Med 8:354–360. https://doi.org/10.1007/bf02600071

Gaidhani A, Moon KS, Ozturk Y, Lee SQ, Youm W (2017) Extraction and analysis of respiratory motion using wearable inertial sensor system during trunk motion. Sensors 17:2932. https://doi.org/10.3390/s17122932

Gollee H, Chen W (2007) Real-time detection of respiratory activity using an inertial measurement unit. Conf Proc IEEE Eng Med Biol Soc 2007:2230–2233. https://doi.org/10.1109/IEMBS.2007.4352768

Hung DP, Bonnet S, Guillemaud R, Castelli E, Pham Thi NY (2008, 2008) Estimation of respiratory waveform using an accelerometer. Conf Proc IEEE Eng Med Biol Soc:1493–1496. https://doi.org/10.1109/IEMBS.2008.4650316

Iandelli I, Aliverti A, Kayser B, Dellacà R, Cala SJ, Duranti R, Kelly S, Scano G, Sliwinski P, Yan S (2002) Determinants of exercise performance in normal men with externally imposed expiratory flow limitation. J Appl Physiol 92:1943–1952. https://doi.org/10.1152/japplphysiol.00393.2000

Jin A, Yin B, Morren G, Duric H, Aarts RM (2009) Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living. Conf Proc IEEE Eng Med Biol Soc 2009:5677–5680. https://doi.org/10.1109/IEMBS.2009.5333116

Kenyon C, Cala S, Yan S, Aliverti A, Scano G, Duranti R, Pedotti A, Macklem PT (1997) Rib cage mechanics during quiet breathing and exercise in humans. J Appl Physiol 83:1242–1255. https://doi.org/10.1152/jappl.1997.83.4.1242

Konno K, Mead J (1967) Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol 22:407–422. https://doi.org/10.1152/jappl.1967.22.3.407

Kontaxis S, Lazaro J, Corino VD, Sandberg F, Bailón R, Laguna P, Sörnmo L (2019, 2019) ECG-derived respiratory rate in atrial fibrillation. IEEE Trans Biomed Eng. https://doi.org/10.1109/TBME.2019.2923587

Kuipers JB (1999) Quaternions and rotation sequences. Princeton university press Princeton

Lapi S, Lavorini F, Borgioli G, Calzolai M, Masotti L, Pistolesi M, Fontana GA (2014) Respiratory rate assessment using a dual-accelerometer device. Respir Physiol Neurobiol 191:60–66. https://doi.org/10.1016/j.resp.2013.11.003

Layton AM, Moran SL, Garber CE, Armstrong HF, Basner RC, Thomashow BM, Bartels MN (2013) Optoelectronic plethysmography compared to spirometry during maximal exercise. Respir Physiol Neurobiol 185:362–368. https://doi.org/10.1016/j.resp.2012.09.004

Liu G, Guo Y, Zhu Q, Huang B, Wang L (2011) Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemed J E Health 17:705–711. https://doi.org/10.1089/tmj.2011.0022

Madgwick SO, Harrison AJ, Vaidyanathan A (2011) Estimation of IMU and MARG orientation using a gradient descent algorithm. IEEE Int Conf Rehabil Robot 2011:1–7. https://doi.org/10.1109/ICORR.2011.5975346

Mann J, Rabinovich R, Bates A, Giavedoni S, MacNee W, Arvind DK (2011) Simultaneous activity and respiratory monitoring using an accelerometer. Int Conf Body Sens Netw 2011:139–143. https://doi.org/10.1109/BSN.2011.26

Marins JL, Yun X, Bachmann ER,. McGhee RB, Zyda MJ (2001) An extended Kalman filter for quaternion-based orientation estimation using MARG sensors. Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium. 2001: 2003-2011. DOI: https://doi.org/10.1109/IROS.2001.976367

McCaughey E, McLachlan A, Gollee H (2014) Non-intrusive real-time breathing pattern detection and classification for automatic abdominal functional electrical stimulation. Med Eng Phys 36:1057–1061. https://doi.org/10.1016/j.medengphy.2014.04.005

Moody GB, Mark RG, Bump MA, Weinstein JS, Berman AD, Mietus JE, Goldberger AL (1986) Clinical validation of the ECG-derived respiration (EDR) technique. Comput Cardiol 13:507–510

Kundan Nepal, Eric Biegeleisen and Ning T 2002 Apnea detection and respiration rate estimation through parametric modelling. Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342), 2002: 277-278.DOI: https://doi.org/10.1109/NEBC.2002.999573

Priori R, Aliverti A, Albuquerque AL, Quaranta M, Albert P, Calverley PM (2013) The effect of posture on asynchronous chest wall movement in COPD. J Appl Physiol 114:1066–1075. https://doi.org/10.1152/japplphysiol.00414.2012

Reinvuo T, Hannula M, Sorvoja H, Alasaarela E, Myllyla R (2006) Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor proceedings of the 2006 IEEE Sensors Applications Symposium, 2006: 192–195. DOI: https://doi.org/10.1109/SAS.2006.1634270

Selvaraj N (2014) Long-term remote monitoring of vital signs using a wireless patch sensor. IEEE Healthc Innov Conf (HIC) 2014:83–86. https://doi.org/10.1109/HIC.2014.7038880

Staats BA, Bonekat HW, Harris CD, Offord KP (1984) Chest wall motion in sleep apnea. Am Rev Respir Dis 130:59–63. https://doi.org/10.1164/arrd.1984.130.1.59

Stevenson IH, Teichtahl H, Cunnington D, Ciavarella S, Gordon I, Kalman JM (2008) Prevalence of sleep disordered breathing in paroxysmal and persistent atrial fibrillation patients with normal left ventricular function. Eur Heart J 29:1662–1669. https://doi.org/10.1093/eurheartj/ehn214

Storck K, Karlsson M, Ask P, Loyd D (1996) Heat transfer evaluation of the nasal thermistor technique. IEEE Trans Biomed Eng 43:1187–1191. https://doi.org/10.1109/10.544342

Subbe C, Davies R, Williams E, Rutherford P, Gemmell L (2003) Effect of introducing the modified early warning score on clinical outcomes, cardio-pulmonary arrests and intensive care utilisation in acute medical admissions. Anaesthesia 58:797–802. https://doi.org/10.1046/j.1365-2044.2003.03258.x

Terzano C, Romani S, Conti V, Paone G, Oriolo F, Vitarelli A (2014) Atrial fibrillation in the acute, hypercapnic exacerbations of COPD. Eur Rev Med Pharmacol Sci 18:2908–2917

Tobin MJ, Yang K (1990) Weaning from mechanical ventilation. Crit Care Clin 6:725–747

Torres A, Fiz JA, Galdiz B, Gea J, Morera J, Jané R (2004) Assessment of respiratory muscle effort studying diaphragm movement registered with surface sensors. Animal model (dogs). Conf Proc IEEE Eng Med Biol Soc 2004:3917–3920. https://doi.org/10.1109/IEMBS.2004.1404095

van Loon K, Peelen LM, van de Vlasakker EC, Kalkman CJ, van Wolfswinkel L, van Zaane B (2018) Accuracy of remote continuous respiratory rate monitoring technologies intended for low care clinical settings: a prospective observational study. Can J Anaesth 65:1324–1332. https://doi.org/10.1007/s12630-018-1214-z

Vieira DS, Hoffman M, Pereira DA, Britto RR, Parreira VF (2013) Optoelectronic plethysmography: intra-rater and inter-rater reliability in healthy subjects. Respir Physiol Neurobiol 189:473–476. https://doi.org/10.1016/j.resp.2013.08.023

Werthammer J, Krasner J, DiBenedetto J, Stark AR (1983) Apnea monitoring by acoustic detection of airflow. Pediatrics 71:53–55

Yadollahi A, Moussavi ZM (2006) A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans Biomed Eng 53:662–668. https://doi.org/10.1109/TBME.2006.870231

Yoon J, Noh Y, Kwon Y, Kim W, Yoon H (2014) Improvement of dynamic respiration monitoring through sensor fusion of accelerometer and gyro-sensor. J Electr Eng Technol 9:334–343. https://doi.org/10.5370/JEET.2014.9.1.334

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem