Water quality sensor placement: a multi-objective and multi-criteria approach

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Water quality sensor placement: a multi-objective and multi-criteria approach

Mostrar el registro completo del ítem

Brentan, B.; Carpitella, S.; Barros, D.; Meirelles, G.; Certa, A.; Izquierdo Sebastián, J. (2021). Water quality sensor placement: a multi-objective and multi-criteria approach. Water Resources Management. 35(1):225-241. https://doi.org/10.1007/s11269-020-02720-3

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/180477

Ficheros en el ítem

Metadatos del ítem

Título: Water quality sensor placement: a multi-objective and multi-criteria approach
Autor: Brentan, Bruno Carpitella, Silvia Barros, Daniel Meirelles, Gustavo Certa, Antonella Izquierdo Sebastián, Joaquín
Entidad UPV: Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada
Fecha difusión:
Resumen:
[EN] To satisfy their main goal, namely providing quality water to consumers, water distribution networks (WDNs) need to be suitably monitored. Only well designed and reliable monitoring data enables WDN managers to make ...[+]
Palabras clave: Water distribution systems , Water quality sensor placement , Optimization , ELECTRE TRI
Derechos de uso: Reserva de todos los derechos
Fuente:
Water Resources Management. (issn: 0920-4741 )
DOI: 10.1007/s11269-020-02720-3
Editorial:
Springer-Verlag
Versión del editor: https://doi.org/10.1007/s11269-020-02720-3
Tipo: Artículo

References

Barak S, Mokfi T (2019) Evaluation and selection of clustering methods using a hybrid group mcdm. Expert Syst Appl 138:112817

Berry JW, Fleischer L, Hart WE, Phillips CA, Watson JP (2005) Sensor placement in municipal water networks. J Water Resour Plan Manag 131 (3):237–243

Bouyssou D, Marchant T (2015) On the relations between electre tri-b and electre tri-c and on a new variant of electre tri-b. Eur J Oper Res 242(1):201–211 [+]
Barak S, Mokfi T (2019) Evaluation and selection of clustering methods using a hybrid group mcdm. Expert Syst Appl 138:112817

Berry JW, Fleischer L, Hart WE, Phillips CA, Watson JP (2005) Sensor placement in municipal water networks. J Water Resour Plan Manag 131 (3):237–243

Bouyssou D, Marchant T (2015) On the relations between electre tri-b and electre tri-c and on a new variant of electre tri-b. Eur J Oper Res 242(1):201–211

Brentan B, Carpitella S, Izquierdo J, Luvizotto E Jr, Meirelles G (2019) A multi-objective and multi-criteria approach for district metered area design: water operation and quality analysis. In: International conference on mathematical modeling in engineering & human behaviour, vol 2019, pp 110–117

Brito AJ, de Almeida AT, Mota CM (2010) A multicriteria model for risk sorting of natural gas pipelines based on electre tri integrating utility theory. Eur J Oper Res 200(3):812–821

Broad DR, Maier HR, Dandy GC, Nixon JB (2008) Optimal design of water distribution systems including water quality and system uncertainty. In: Water distribution systems analysis symposium, vol 2006, pp 1–17

Candelieri A, Conti D, Archetti F (2014) A graph based analysis of leak localization in urban water networks. Procedia Eng 70:228–237

Carpitella S, Brentan B, Montalvo I, Izquierdo J, Certa A (2018a) Multi-objective and multi-criteria analysis for optimal pump scheduling in water systems. EPiC Series Eng 3:364–371

Carpitella S, Certa A, Izquierdo J, La Fata CM (2018b) k-out-of-n systems: an exact formula for the stationary availability and multi-objective configuration design based on mathematical programming and topsis. J Comput Appl Math 330:1007–1015

Carpitella S, Ocaña-Levario SJ, Benítez J, Certa A, Izquierdo J (2018c) A hybrid multi-criteria approach to gpr image mining applied to water supply system maintenance. J Appl Geophy 159:754–764

Certa A, Enea M, Galante GM, La Fata CM (2017) Electre tri-based approach to the failure modes classification on the basis of risk parameters: an alternative to the risk priority number. Comput Indust Eng 108:100–110

Cheung P, Piller O, Propato M (2005) Optimal location of water quality sensors in supply systems by multiobjective genetic algorithms. In: Eight international conference on computing and control in the water industry CCWI05, vol 1, p 2

Christodoulou SE, Gagatsis A, Xanthos S, Kranioti S, Agathokleous A, Fragiadakis M (2013) Entropy-based sensor placement optimization for waterloss detection in water distribution networks. Water Resour Manag 27 (13):4443–4468

Corrente S, Greco S, Słowiński R (2016) Multiple criteria hierarchy process for electre tri methods. Eur J Oper Res 252(1):191–203

Costa AS, Govindan K, Figueira JR (2018) Supplier classification in emerging economies using the electre tri-nc method: a case study considering sustainability aspects. J Clean Prod 201:925–947

De Schaetzen W, Walters G, Savic D (2000) Optimal sampling design for model calibration using shortest path, genetic and entropy algorithms. Urban Water 2(2):141–152

de Winter C, Palleti VR, Worm D, Kooij R (2019) Optimal placement of imperfect water quality sensors in water distribution networks. Comput Chem Eng 121:200–211

Deb K, Pratap A, Agarwal S, Meyarivan T (2002) A fast and elitist multiobjective genetic algorithm: Nsga-ii. IEEE Trans Evol Comput 6 (2):182–197

Dias LC, Antunes CH, Dantas G, de Castro N, Zamboni L (2018) A multi-criteria approach to sort and rank policies based on delphi qualitative assessments and electre tri: the case of smart grids in brazil. Omega 76:100–111

Eliades DG, Kyriakou M, Vrachimis S, Polycarpou MM (2016) Epanet-matlab toolkit: An open-source software for interfacing epanet with matlab. In: Proceedings of the 14th international conference on computing and control for the water industry, CCWI

Fernandez E, Navarro J (2011) A new approach to multi-criteria sorting based on fuzzy outranking relations: the theseus method. Eur J Oper Res 213 (2):405–413

Fernández E, Figueira JR, Navarro J, Roy B (2017) Electre tri-nb: a new multiple criteria ordinal classification method. Eur J Oper Res 263 (1):214–224

Figueira JR, Greco S, Roy B, Słowiński R (2010) Electre methods: main features and recent developments. In: Handbook of multicriteria analysis. Springer, New York, pp 51–89

Figueira JR, Greco S, Roy B, Słowiński R (2013) An overview of electre methods and their recent extensions. J Multi-Criteria Dec Anal 20 (1-2):61–85

Francés-Chust J, Brentan BM, Carpitella S, Izquierdo J, Montalvo I (2020) Optimal placement of pressure sensors using fuzzy dematel-based sensor influence. Water 12(2):493

Gandy M (2004) Rethinking urban metabolism: water, space and the modern city. City 8(3):363–379

Giudicianni C, Herrera M, Di Nardo A, Greco R, Creaco E, Scala A (2020) Topological placement of quality sensors in water-distribution networks without the recourse to hydraulic modeling. J Water Resour Plan Manag 146 (6):04020030

Hart WE, Murray R (2010) Review of sensor placement strategies for contamination warning systems in drinking water distribution systems. J Water Resour Plan Manag 136(6):611–619

Herrera M, Abraham E, Stoianov I (2016) A graph-theoretic framework for assessing the resilience of sectorised water distribution networks. Water Resour Manag 30(5):1685–1699

Huang JJ, McBean EA, James W (2008) Multi-objective optimization for monitoring sensor placement in water distribution systems. In: Water distribution systems analysis symposium, vol 2006, pp 1–14

Kapelan ZS, Savic DA, Walters GA (2003) A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks. J Hydraul Res 41(5):481–492

Lee JH (2013) Determination of optimal water quality monitoring points in sewer systems using entropy theory. Entropy 15(9):3419–3434

Liu Z, Ming X (2019) A methodological framework with rough-entropy-electre tri to classify failure modes for co-implementation of smart pss. Adv Eng Inform 42:100968

Marchi A, Salomons E, Ostfeld A, Kapelan Z, Simpson AR, Zecchin AC, Maier HR, Wu ZY, Elsayed SM, Song Y et al (2013) Battle of the water networks ii. J Water Resour Plan Manag 140(7):04014009

Mohammed A, Harris I, Soroka A, Nujoom R (2019) A hybrid mcdm-fuzzy multi-objective programming approach for a g-resilient supply chain network design. Comput Indust Eng 127:297–312

Montalvo I, Izquierdo J, Pérez-garcía R, Herrera M (2014) Water distribution system computer-aided design by agent swarm optimization. Comput-Aided Civ Inf Eng 29(6):433–448

Mousseau V, Slowinski R, Zielniewicz P (2000) A user-oriented implementation of the electre-tri method integrating preference elicitation support. Comput Opera Res 27(7-8):757–777

Nafi A, Crastes E, Sadiq R, Gilbert D, Piller O (2018) Intentional contamination of water distribution networks: developing indicators for sensitivity and vulnerability assessments. Stoch Environ Res Risk Assess 32(2):527–544

Neto JGD, Machado MAS, Gomes LFAM, Caldeira AM, Sallum FSV (2017) Investments in a new technological infrastructure: Decision making using the electre-tri methodology. Procedia Comput Sci 122:194–199

Ohar Z, Lahav O, Ostfeld A (2015) Optimal sensor placement for detecting organophosphate intrusions into water distribution systems. Water Res 73:193–203

Oliker N, Ostfeld A (2015) Network hydraulics inclusion in water quality event detection using multiple sensor stations data. Water Res 80:47–58

Ostfeld A, Salomons E (2005) Optimal early warning monitoring system layout for water networks security: Inclusion of sensors sensitivities and response delays. Civ Eng Environ Syst 22(3):151–169

Ostfeld A, Uber JG, Salomons E, Berry JW, Hart WE, Phillips CA, Watson JP, Dorini G, Jonkergouw P, Kapelan Z et al (2008) The battle of the water sensor networks (bwsn): A design challenge for engineers and algorithms. J Water Resour Plan Manag 134(6):556–568

Quiñones-Grueiro M, Verde C, Llanes-santiago O (2019) Multi-objective sensor placement for leakage detection and localization in water distribution networks. In: 2019 4th conference on control and fault tolerant systems (SysTol), IEEE, pp 129–134

Ramezanian R (2019) Estimation of the profiles in posteriori electre tri: A mathematical programming model. Comput Indust Eng 128:47–59

Rathi S, Gupta R, Kamble S, Sargaonkar A (2016) Risk based analysis for contamination event selection and optimal sensor placement for intermittent water distribution network security. Water Resour Manag 30(8):2671–2685

Reginaldo F (2015) Portfolio management in Brazil and a proposal for evaluation and balancing of portfolio projects with electre tri and iris. Procedia Comput Sci 55:1265–1274

Roy B (1968) Classement et choix en présence de points de vue multiples. Revue française d’informatique et de recherche opérationnelle 2(8):57–75

Roy B (1990) The outranking approach and the foundations of electre methods. In: Readings in multiple criteria decision aid. Springer, New York, pp 155–183

Sánchez-Lozano J, García-cascales M, Lamata M (2016) Comparative topsis-electre tri methods for optimal sites for photovoltaic solar farms. case study in spain. J Clean Prod 127:387–398

Seiti H, Hafezalkotob A, Najafi SE, Khalaj M (2019) Developing a novel risk-based mcdm approach based on d numbers and fuzzy information axiom and its applications in preventive maintenance planning. Appl Soft Comput: 105559

Shang F, Uber JG, Rossman LA et al (2008) Epanet multi-species extension user’s manual. risk reduction engineering laboratory us environmental protection agency. Cincinnati, Ohio

Shannon CE (1948) A mathematical theory of communication. Bell Syst Tech J 27(3):379–423

Štirbanović Z, Stanujkić D, Miljanović I, Milanović D (2019) Application of mcdm methods for flotation machine selection. Miner Eng 137:140–146

Wang H, Jiang Z, Zhang H, Wang Y, Yang Y, Li Y (2019) An integrated mcdm approach considering demands-matching for reverse logistics. J Clean Prod 208:199–210

Wéber R, Hős C (2020) Efficient technique for pipe roughness calibration and sensor placement for water distribution systems. J. Water Resour Plan Manag 146(1):04019070

Weickgenannt M, Kapelan Z, Blokker M, Savic DA (2010) Risk-based sensor placement for contaminant detection in water distribution systems. J Water Resour Plan Manag 136(6):629–636

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem