- -

Higher reproducibility of phase derived metrics from electrocardiographic imaging during atrial fibrillation in patients remaining in sinus rhythm after pulmonary vein isolation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Higher reproducibility of phase derived metrics from electrocardiographic imaging during atrial fibrillation in patients remaining in sinus rhythm after pulmonary vein isolation

Mostrar el registro completo del ítem

Molero-Alabau, R.; Soler Torro, JM.; Martínez Alzamora, MN.; Climent, AM.; Guillem Sánchez, MS. (2021). Higher reproducibility of phase derived metrics from electrocardiographic imaging during atrial fibrillation in patients remaining in sinus rhythm after pulmonary vein isolation. Computers in Biology and Medicine. 139:1-7. https://doi.org/10.1016/j.compbiomed.2021.104934

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/183953

Ficheros en el ítem

Metadatos del ítem

Título: Higher reproducibility of phase derived metrics from electrocardiographic imaging during atrial fibrillation in patients remaining in sinus rhythm after pulmonary vein isolation
Autor: Molero-Alabau, Rubén Soler Torro, Jose Manuel Martínez Alzamora, Mª Nieves Climent, Andreu M. Guillem Sánchez, María Salud
Entidad UPV: Universitat Politècnica de València. Departamento de Estadística e Investigación Operativa Aplicadas y Calidad - Departament d'Estadística i Investigació Operativa Aplicades i Qualitat
Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Fecha difusión:
Resumen:
[EN] Background: Electrocardiographic imaging (ECGI) allows evaluating the complexity of the reentrant activity of atrial fibrillation (AF) patients. In this study, we evaluated the ability of ECGI metrics to predict the ...[+]
Palabras clave: Atrial fibrillation , Electrocardiographic imaging , Reproducibility , Reentrant activity , Pulmonary vein isolation
Derechos de uso: Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
Fuente:
Computers in Biology and Medicine. (issn: 0010-4825 )
DOI: 10.1016/j.compbiomed.2021.104934
Editorial:
Elsevier
Versión del editor: https://doi.org/10.1016/j.compbiomed.2021.104934
Código del Proyecto:
info:eu-repo/grantAgreement/MCIU//RYC2018-024346B-750/
info:eu-repo/grantAgreement/GVA//ACIF%2F2020%2F265/
info:eu-repo/grantAgreement/FEDER//EITHealth 19600 AFFINE/
info:eu-repo/grantAgreement/ISCIII//PI17%2F01106/
Agradecimientos:
This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia, Innovacion y Universidades (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106 and RYC2018- 024346B-750), EIT Health ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem