Análisis y calificación energética del edificio 8H del Campus de Vera de la Universitat Politècnica de València. Diseño y estudio técnico-económico de los elementos incluidos en la rehabilitación energética del edificio

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Análisis y calificación energética del edificio 8H del Campus de Vera de la Universitat Politècnica de València. Diseño y estudio técnico-económico de los elementos incluidos en la rehabilitación energética del edificio

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Rodríguez Hernández, José Carlos es_ES
dc.contributor.author Aneas Cambil, Alejandro es_ES
dc.date.accessioned 2022-10-06T11:49:31Z
dc.date.available 2022-10-06T11:49:31Z
dc.date.created 2022-07-15
dc.date.issued 2022-10-06 es_ES
dc.identifier.uri http://hdl.handle.net/10251/187170
dc.description.abstract [ES] El presente Trabajo Final de Máster se pretende hacer una auditoría energética completa del edificio 8H del Campus de Vera, haciendo un análisis primario de los consumos e instalaciones de este y posteriormente realizando su calificación energética oportuna. A continuación, y una vez conocidos los sumideros energéticos del edificio procedemos al diseño y al estudio técnico-económico de las medidas de mejora energética del edificio. Para realizar todo este trabajo se ha procedido al uso de la suite de CYPE. En primer lugar y para realizar el análisis correcto de los consumos y posteriormente poderlos utilizar con PVSyst, se ha llevado a cabo una adecuación de los datos recibidos por parte de la ingeniería ya que es necesario tener un formato específico para poder estudiarlos de forma correcta. A continuación, se ha hecho la calificación energética del mismo, teniendo en cuenta los elementos constructivos que se indican en el pliego de condiciones técnicas de anteriores reformas de este, con ello y teniendo en cuenta bases de datos webs sobre composición de muros de edificios según su localización y año proporcionados por el IVE (Instituto Valenciano de la Edificación) se ha podido realizar una aproximación realista de los datos necesitados para realizar la calificación. Posteriormente, y una vez realizada la calificación energética del edificio, se pasa al diseño y estudio técnico económico de las medidas de mejora incorporadas. Para ello se ha hecho uso tanto de los programas CYPE Lux como CYPE Therm Loads y posteriormente Open Bim DAIKIN para los sistemas de climatización propuestos. Además, se han dimensionado los sistemas de producción solar fotovoltaica con PVSyst y SketchUp y el sistema de producción de ACS que se desacople de la centralización del campus. Finalmente, se ha realizado el estudio técnico-económico de los sistemas incorporados y presentado presupuesto de la rehabilitación completa. es_ES
dc.description.abstract [EN] The aim of this Master's Final Project is to carry out a complete energy audit of the 8H building on the Vera Campus, carrying out a primary analysis of the building's consumption and installations and subsequently carrying out the appropriate energy rating. Afterwards, and once the energy sinks of the building are known, we proceed to the design and the technical-economic study of the energy improvement measures of the building. To carry out all this work, we have used the CYPE suite. Firstly, in order to carry out the correct analysis of the consumption and subsequently be able to use them with PVSyst, the data received from the engineering department was adapted, as it is necessary to have a specific format to be able to study them correctly. Next, the energy rating of the building has been carried out, considering the construction elements indicated in the technical specifications of previous reforms of the building. With this and considering web databases on the composition of building walls according to their location and year provided by the IVE (Valencian Institute of Building), it has been possible to make a realistic approximation of the data needed to carry out the rating. Subsequently, and once the energy rating of the building has been carried out, the design and technical-economic study of the improvement measures incorporated is carried out. For this purpose, both CYPE Lux and CYPE Therm Loads, and later Open Bim DAIKIN programs have been used for the proposed air conditioning systems. In addition, the photovoltaic solar production systems have been dimensioned with PVSyst and SketchUp and the DHW production system that is decoupled from the centralization of the campus. Finally, the technical-economic study of the incorporated systems has been carried out and a budget for the complete refurbishment has been presented. es_ES
dc.format.extent 271 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Análisis energético es_ES
dc.subject Calificación energética es_ES
dc.subject Energías renovables es_ES
dc.subject Edificio de consumo casi nulo es_ES
dc.subject Rehabilitación energética es_ES
dc.subject Climatización es_ES
dc.subject Iluminación es_ES
dc.subject ACS. es_ES
dc.subject Energy analysis es_ES
dc.subject Energy rating es_ES
dc.subject Renewable energies es_ES
dc.subject Near-zero energy building es_ES
dc.subject Energy rehabilitation es_ES
dc.subject Air conditioning es_ES
dc.subject Lighting es_ES
dc.subject DHW. es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.other Máster Universitario en Tecnología Energética para Desarrollo Sostenible-Màster Universitari en Tecnologia Energètica per Al Desenvolupament Sostenible es_ES
dc.title Análisis y calificación energética del edificio 8H del Campus de Vera de la Universitat Politècnica de València. Diseño y estudio técnico-económico de los elementos incluidos en la rehabilitación energética del edificio es_ES
dc.title.alternative Analysis and energy rating of the building 8H on the Vera Campus of the Polytechnic University of Valencia. Design and technical-economic study of the elements included in the energy rehabilitation of the building. es_ES
dc.title.alternative Anàlisi i qualificació energètica de l edifici 8H del Campus de Vera de la Universitat Politècnica de València. Disseny i estudi técnico-econòmic dels elements inclosos a la rehabilitació energètica de l'edifici. es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Aneas Cambil, A. (2022). Análisis y calificación energética del edificio 8H del Campus de Vera de la Universitat Politècnica de València. Diseño y estudio técnico-económico de los elementos incluidos en la rehabilitación energética del edificio. Universitat Politècnica de València. http://hdl.handle.net/10251/187170 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\152246 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem