dc.description.abstract [EN] The instrumentation and supervision of water distribution networks (WDN) are challenging tasks as the use of monitoring devices imply a high cost including installation and maintenance. One of the emerging issues is the definition of the best possible layout of the measurements to be recorded. Considering the sampling costs and budget limitations on the number of sensors to be distributed, to determine a trade-off is mandatory. The trade-off may highly depend on the final use of these sensors. This work presents a methodology to support practitioners to decide which is the optimal pressure sensor placement and the appropriate number of pressure sensors to install on a WDN. Two main applications for demand calibration and leak detection and localisation are considered. A sensor placement methodology is applied to find the most sensible locations with respect to demand groups. Additionally, as the sensor placement methodology does not define an optimal number of sensors to be distributed in the WDN, an approach to formulate a trade-off is developed. This approach generates an indicator that quantifies the degree of relevance of the information recorded by a given sensor layout. The methodology presented is applied on a real WDN to select the most appropriate pressure measurement layout as part of an instrumentation project plan. es_ES
dc.format.extent 15 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof 2nd International Join Conference on Water Distribution System Analysis (WDSA) & Computing and Control in the Water Industry (CCWI)
dc.rights Reconocimiento - No comercial - Compartir igual (by-nc-sa) es_ES
dc.subject Water Distribution Networks es_ES
dc.subject Sampling design es_ES
dc.subject Sensors es_ES
dc.title Pressure Sensor Placement In Water Networks Based On Sensitivity Matrix: A Real Instrumentation Project Plan es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/WDSA-CCWI2022.2022.14733
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Van Eeckhout, J.; Cugueró, J.; Pérez, R. (2024). Pressure Sensor Placement In Water Networks Based On Sensitivity Matrix: A Real Instrumentation Project Plan. Editorial Universitat Politècnica de València. https://doi.org/10.4995/WDSA-CCWI2022.2022.14733 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 2nd WDSA/CCWI Joint Conference es_ES
dc.relation.conferencedate Julio 18-22, 2022 es_ES
dc.relation.conferenceplace Valencia, España es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/WDSA-CCWI/WDSA-CCWI2022/paper/view/14733 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\14733 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem