Pumping Station Design with an Analysis of Variability of Demand and Considering Techno-Economic and Environmental Criteria through the AHP Method

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Pumping Station Design with an Analysis of Variability of Demand and Considering Techno-Economic and Environmental Criteria through the AHP Method

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Briceño-León, Christian es_ES
dc.contributor.author Iglesias-Rey, Pedro es_ES
dc.contributor.author Martínez-Solano, Francisco es_ES
dc.contributor.author Creaco, Enrico es_ES
dc.date.accessioned 2024-07-12T09:21:27Z
dc.date.available 2024-07-12T09:21:27Z
dc.date.issued 2024-03-06
dc.identifier.isbn 9788490489826
dc.identifier.uri http://hdl.handle.net/10251/206038
dc.description.abstract [EN] Pumping stations costs including, capital and operational costs are some of the highest costs in urban water distribution system. A proper pumping station design could be defined as the solution with the minimum life cycle cost and satisfying extreme scenarios in water distribution system. These costs are associated with investment, operational and maintenance costs. However, there are some important aspects to consider un a pumping station design, such as the feasibility of infrastructure construction, the size of the infrastructure, and the complexity of operation in the pumping station. These aspects are associated with technical criteria. In a classical pumping station design, the number of pumps is determined in arbitrary form according to the criteria of the engineer, and the pump model is selected according to the maximum requirements of flow and pressure of the network. In summary, these variables in a pumping station design are not usually analyzed deeply.  In addition, global warming acceleration in the last decades has gained momentum to be considered in engineering problems to mitigate the environmental impact. Hence, it is imperative to consider environmental aspects, such as greenhouse emission, energetic efficiency of the pump in modern pumping systems of water distribution networks. Finally, the most suitable solution is determined only by analyzing economic aspects. Therefore, this work proposed a methodology to design pumping stations in urban water networks considering technical, environmental, and economic criteria and link them together through the Analytic Hierarchy Process (AHP) method. The propose of this method is to determine the importance priority of these aspects to assess the possible solutions and determine the most suitable solution in the pumping station design. In addition, this work considers the variability of demand pattern. This work analyses several scenarios of demand patterns from the minimum possible demand to the maximum possible demand in a water distribution network and the respective probabilities of occurrence of scenario. It allows that the pumping station design be more robust. This methodology has been applied in different case studies to analyze how affects to determine the most suitable solution when the characteristics of the network change. es_ES
dc.format.extent 17 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof 2nd International Join Conference on Water Distribution System Analysis (WDSA) & Computing and Control in the Water Industry (CCWI)
dc.rights Reconocimiento - No comercial - Compartir igual (by-nc-sa) es_ES
dc.subject Pumping station es_ES
dc.subject AHP es_ES
dc.subject Variability of demand es_ES
dc.subject Life cycle costs es_ES
dc.subject Technical criteria es_ES
dc.subject Economic criteria es_ES
dc.subject Environmental criteria es_ES
dc.title Pumping Station Design with an Analysis of Variability of Demand and Considering Techno-Economic and Environmental Criteria through the AHP Method es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/WDSA-CCWI2022.2022.14098
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Briceño-León, C.; Iglesias-Rey, P.; Martínez-Solano, F.; Creaco, E. (2024). Pumping Station Design with an Analysis of Variability of Demand and Considering Techno-Economic and Environmental Criteria through the AHP Method. Editorial Universitat Politècnica de València. https://doi.org/10.4995/WDSA-CCWI2022.2022.14098 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 2nd WDSA/CCWI Joint Conference es_ES
dc.relation.conferencedate Julio 18-22, 2022 es_ES
dc.relation.conferenceplace Valencia, España es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/WDSA-CCWI/WDSA-CCWI2022/paper/view/14098 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\14098 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem