Mostrar el registro sencillo del ítem
dc.contributor.author | Soriano Asensi, Antonio | es_ES |
dc.contributor.author | Rodríguez Álvarez, María José | es_ES |
dc.contributor.author | Iborra Carreres, Amadeo | es_ES |
dc.contributor.author | Sánchez Martínez, Filomeno | es_ES |
dc.contributor.author | Carles Fariña, Montserrat | es_ES |
dc.contributor.author | Conde Castellanos, Pablo Eloy | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Hernández Hernández, Liczandro | es_ES |
dc.contributor.author | Moliner Martínez, Laura | es_ES |
dc.contributor.author | Orero Palomares, Abel | es_ES |
dc.contributor.author | Vidal San Sebastián, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.date.accessioned | 2014-04-25T08:37:07Z | |
dc.date.available | 2014-04-25T08:37:07Z | |
dc.date.issued | 2013-01 | |
dc.identifier.issn | 1748-0221 | |
dc.identifier.uri | http://hdl.handle.net/10251/37155 | |
dc.description.abstract | [EN] The splitting of the field of view (FOV) in polar voxels is proposed in this work in order to obtain an efficient description of a cone-beam computed tomography (CT) scanner. The proposed symmetric-polar pixelation makes it possible to deal with the 3D iterative reconstruction considering a number of projections and voxel sizes typical in CT preclinical imaging. The performance comparison, between the filtered backprojection (FBP) and 3D maximum likelihood expectation maximization (MLEM) reconstruction algorithm for CT, is presented. It is feasible to achieve the hardware spatial resolution limit with the considered pixelation. The image quality achieved with MLEM and FBP have been analyzed. The results obtained with both algorithms in clinical images have been compared too. Although the polar-symmetric pixelation is presented in the context of CT imaging, it can be applied to any other tomographic technique as long as the scan comprises the measurement of an object under several projection angles. | es_ES |
dc.description.sponsorship | This work was supported by the Spanish Plan Nacional de Investigaci´on Cient´ıfica, Desarrollo e Innovaci´on Tecnol´ogica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEO/2008/114, ISIC/2012/013 and APOSTD/2010/012. | |
dc.format.extent | 7 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Physics: Hybrid Open Access | es_ES |
dc.relation.ispartof | Journal of Instrumentation | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Image reconstruction in medical imaging | es_ES |
dc.subject | Data reduction methods | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | EM tomographic image reconstruction using polarvoxels | es_ES |
dc.type | Artículo | es_ES |
dc.type | Comunicación en congreso | |
dc.identifier.doi | 10.1088/1748-0221/8/01/C01004 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//SIC%2F2012%2F013/ES/Red de Excelencia de Imagen Biomédica/ | |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//APOSTD%2F2010%2F012/ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Soriano Asensi, A.; Rodríguez Álvarez, MJ.; Iborra Carreres, A.; Sánchez Martínez, F.; Carles Fariña, M.; Conde Castellanos, PE.; González Martínez, AJ.... (2013). EM tomographic image reconstruction using polarvoxels. Journal of Instrumentation. 8(12):1-7. https://doi.org/10.1088/1748-0221/8/01/C01004 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | 14th International Workshop on Radiation Imaging Detectors (IWORID2012) | es_ES |
dc.relation.conferencename | 14th International Workshop on Radiation Imaging Detectors | |
dc.relation.conferencedate | JUL 01-05, 2012 | es_ES |
dc.relation.conferencedate | July 01-05, 2012 | |
dc.relation.conferenceplace | Figueira da Foz, Portugal | |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 7 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 8 | es_ES |
dc.description.issue | 12 | es_ES |
dc.relation.senia | 231972 | |
dc.contributor.funder | Comisión Interministerial de Ciencia y Tecnología | |
dc.contributor.funder | Generalitat Valenciana | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |