Soriano Asensi, A.; Rodríguez Álvarez, MJ.; Iborra Carreres, A.; Sánchez Martínez, F.; Carles Fariña, M.; Conde Castellanos, PE.; González Martínez, AJ.... (2013). EM tomographic image reconstruction using polarvoxels. Journal of Instrumentation. 8(12):1-7. https://doi.org/10.1088/1748-0221/8/01/C01004
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/37155
Título:
|
EM tomographic image reconstruction using polarvoxels
|
Autor:
|
Soriano Asensi, Antonio
Rodríguez Álvarez, María José
Iborra Carreres, Amadeo
Sánchez Martínez, Filomeno
Carles Fariña, Montserrat
Conde Castellanos, Pablo Eloy
González Martínez, Antonio Javier
Hernández Hernández, Liczandro
Moliner Martínez, Laura
Orero Palomares, Abel
Vidal San Sebastián, Luis Fernando
Benlloch Baviera, Jose María
|
Entidad UPV:
|
Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada
Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
|
Fecha difusión:
|
|
Resumen:
|
[EN] The splitting of the field of view (FOV) in polar voxels is proposed in this work in
order to obtain an efficient description of a cone-beam computed tomography (CT) scanner. The
proposed symmetric-polar pixelation ...[+]
[EN] The splitting of the field of view (FOV) in polar voxels is proposed in this work in
order to obtain an efficient description of a cone-beam computed tomography (CT) scanner. The
proposed symmetric-polar pixelation makes it possible to deal with the 3D iterative reconstruction
considering a number of projections and voxel sizes typical in CT preclinical imaging.
The performance comparison, between the filtered backprojection (FBP) and 3D maximum
likelihood expectation maximization (MLEM) reconstruction algorithm for CT, is presented. It
is feasible to achieve the hardware spatial resolution limit with the considered pixelation. The
image quality achieved with MLEM and FBP have been analyzed. The results obtained with both
algorithms in clinical images have been compared too. Although the polar-symmetric pixelation is
presented in the context of CT imaging, it can be applied to any other tomographic technique as
long as the scan comprises the measurement of an object under several projection angles.
[-]
|
Palabras clave:
|
Image reconstruction in medical imaging
,
Data reduction methods
|
Derechos de uso:
|
Reserva de todos los derechos
|
Fuente:
|
Journal of Instrumentation. (issn:
1748-0221
)
|
DOI:
|
10.1088/1748-0221/8/01/C01004
|
Editorial:
|
Institute of Physics: Hybrid Open Access
|
Título del congreso:
|
14th International Workshop on Radiation Imaging Detectors (IWORID2012)
14th International Workshop on Radiation Imaging Detectors
|
Lugar del congreso:
|
Figueira da Foz, Portugal
|
Fecha congreso:
|
JUL 01-05, 2012
July 01-05, 2012
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./
info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/
info:eu-repo/grantAgreement/GVA//SIC%2F2012%2F013/ES/Red de Excelencia de Imagen Biomédica/
info:eu-repo/grantAgreement/GVA//APOSTD%2F2010%2F012/
|
Agradecimientos:
|
This work was supported by the Spanish Plan Nacional de Investigaci´on Cient´ıfica, Desarrollo e Innovaci´on Tecnol´ogica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEO/2008/114, ...[+]
This work was supported by the Spanish Plan Nacional de Investigaci´on Cient´ıfica, Desarrollo e Innovaci´on Tecnol´ogica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEO/2008/114, ISIC/2012/013 and APOSTD/2010/012.
[-]
|
Tipo:
|
Artículo
Comunicación en congreso
|