Design of the PET–MR system for head imaging of the DREAM Project

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Design of the PET–MR system for head imaging of the DREAM Project

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Conde, P. es_ES
dc.contributor.author Hernández Hernández, Liczandro es_ES
dc.contributor.author Herrero Bosch, Vicente es_ES
dc.contributor.author Moliner Martínez, Laura es_ES
dc.contributor.author Monzó Ferrer, José María es_ES
dc.contributor.author Orero Palomares, Abel es_ES
dc.contributor.author Peiró Cloquell, Antonio es_ES
dc.contributor.author Rodríguez-Alvarez, M.J. es_ES
dc.contributor.author Ros García, Ana es_ES
dc.contributor.author Sánchez Martínez, Filomeno es_ES
dc.contributor.author Soriano Asensi, Antonio es_ES
dc.contributor.author Vidal San Sebastián, Luis Fernando es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.date.accessioned 2014-10-06T15:43:10Z
dc.date.available 2014-10-06T15:43:10Z
dc.date.issued 2013-02-21
dc.identifier.issn 0168-9002
dc.identifier.uri http://hdl.handle.net/10251/40669
dc.description NOTICE: this is the author’s version of a work that was accepted for publication in Nuclear Instruments and Methods in Physics Research Section A. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A, Volume 702, 21 February 2013, Pages 94–97 DOI 10.1016/j.nima.2012.08.028 es_ES
dc.description.abstract In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems. es_ES
dc.description.sponsorship This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I + D + I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Hybrid PET–MR es_ES
dc.subject SiPM es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Design of the PET–MR system for head imaging of the DREAM Project es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.nima.2012.08.028
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//IDI-20110718/ES/INVESTIGACIÓN EN DETECCIÓN PARA APLICACIONES DE SALUD MENTAL (1%2F3)/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.description.bibliographicCitation González Martínez, AJ.; Conde, P.; Hernández Hernández, L.; Herrero Bosch, V.; Moliner Martínez, L.; Monzó Ferrer, JM.; Orero Palomares, A.... (2013). Design of the PET–MR system for head imaging of the DREAM Project. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:94-97. https://doi.org/10.1016/j.nima.2012.08.028 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.nima.2012.08.028 es_ES
dc.description.upvformatpinicio 94 es_ES
dc.description.upvformatpfin 97 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 702 es_ES
dc.relation.senia 241713
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem