- -

Monitoring of cleanliness and disinfection in dairies: Comparison of traditional microbiological and ATP bioluminescence methods

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Monitoring of cleanliness and disinfection in dairies: Comparison of traditional microbiological and ATP bioluminescence methods

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Carrascosa, Conrado es_ES
dc.contributor.author Saavedra, Pedro es_ES
dc.contributor.author Millán, Rafael es_ES
dc.contributor.author Jaber, José R. es_ES
dc.contributor.author Pérez, Esteban es_ES
dc.contributor.author Grau Meló, Raúl es_ES
dc.contributor.author Raposo, Antonio es_ES
dc.contributor.author Mauricio, Cristina es_ES
dc.contributor.author Sanjuán, Esther es_ES
dc.date.accessioned 2014-12-05T11:09:52Z
dc.date.available 2014-12-05T11:09:52Z
dc.date.issued 2012-12
dc.identifier.issn 0956-7135
dc.identifier.uri http://hdl.handle.net/10251/45217
dc.description.abstract The levels of aerobic contamination at different points in the production chain (curd vat, filler, mould, table and tank) at five cheese factories were analysed using contact plates, dipslides and bioluminescence methods. Almost all the cheese factories showed similar levels of contamination. ATP bioluminescence detected the largest number of unacceptable surfaces (47.7%), followed by the contact plates (41%) and dipslides (34.2%). The dipslide and contact plate methods showed moderate concordance and significant differences (p < 0.001) between the various surfaces sampled. The points in the production chain were classified according to contamination rates, being minimal in the curd vats-fillers and maximal in tables-moulds. The same surfaces were also sampled to determine total Enterobacteriaceae, mould and yeast growth using contact plates and dipslides and no concordance between these two methods was detected. These results were analysed and discussed taking into account the importance of cleanliness and disinfection in cheese factories, as a prerequisite of the HACCP (Hazard Analysis of Critical Control Points) quality assurance system. © 2012 Elsevier Ltd. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Food Control es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject ATP bioluminescence es_ES
dc.subject Cheese factories es_ES
dc.subject Contact plates es_ES
dc.subject Dipslides es_ES
dc.subject Surface cleanliness es_ES
dc.subject Enterobacteriaceae es_ES
dc.subject.classification TECNOLOGIA DE ALIMENTOS es_ES
dc.title Monitoring of cleanliness and disinfection in dairies: Comparison of traditional microbiological and ATP bioluminescence methods es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.foodcont.2012.05.001
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Tecnología de Alimentos - Departament de Tecnologia d'Aliments es_ES
dc.description.bibliographicCitation Carrascosa, C.; Saavedra, P.; Millán, R.; Jaber, JR.; Pérez, E.; Grau Meló, R.; Raposo, A.... (2012). Monitoring of cleanliness and disinfection in dairies: Comparison of traditional microbiological and ATP bioluminescence methods. Food Control. 28(2):368-373. doi:10.1016/j.foodcont.2012.05.001 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.foodcont.2012.05.001 es_ES
dc.description.upvformatpinicio 368 es_ES
dc.description.upvformatpfin 373 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 28 es_ES
dc.description.issue 2 es_ES
dc.relation.senia 231637


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem