- -

Radiofrequency cardiac ablation with catheters placed on opposing sides of the ventricular wall: Computer modelling comparing bipolar and unipolar modes

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Radiofrequency cardiac ablation with catheters placed on opposing sides of the ventricular wall: Computer modelling comparing bipolar and unipolar modes

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author González Suárez, Ana es_ES
dc.contributor.author Trujillo Guillen, Macarena es_ES
dc.contributor.author Koruth, Jacob es_ES
dc.contributor.author d'Avila, Andre es_ES
dc.contributor.author Berjano, Enrique es_ES
dc.date.accessioned 2015-01-07T18:22:04Z
dc.date.available 2015-01-07T18:22:04Z
dc.date.issued 2014-09
dc.identifier.issn 0265-6736
dc.identifier.uri http://hdl.handle.net/10251/45852
dc.description.abstract Purpose: The aim of this study was to compare the efficacy of bipolar (BM) vs. unipolar (UM) mode of radiofrequency ablation (RFA) in terms of creating transmural lesions across the interventricular septum (IVS) and ventricular free wall (VFW). Materials and methods: We built computational models to study the temperature distributions and lesion dimensions created by BM and UM on IVS and VFW during RFA. Two different UM types were considered: sequential (SeUM) and simultaneous (SiUM). The effect of ventricular wall thickness, catheter misalignment, epicardial fat, and presence of air in the epicardial space were also studied. Results: Regarding IVS ablation, BM created transmural and symmetrical lesions for wall thicknesses up to 15 mm. SeUM and SiUM were not able to create transmural lesions with IVS thicknesses >= 12.5 and 15 mm, respectively. Lesions were asymmetrical only with SeUM. For VFW ablation, BM also created transmural lesions for wall thicknesses up to 15 mm. However, with SeUM and SiUM transmurality was obtained for VFW thicknesses <= 7.5 and 12.5 mm, respectively. With the three modes, VFW lesions were always asymmetrical. In the scenario with air or a fat tissue layer on the epicardial side, only SiUM was capable of creating transmural lesions. Overall, BM was superior to UM in IVS and VFW ablation when the catheters were not aligned. Conclusions: Our findings suggest that BM is more effective than UM in achieving transmurality across both ventricular sites, except in the situation of the epicardial catheter tip surrounded by air or placed over a fat tissue layer. es_ES
dc.description.sponsorship This work received financial support from the Spanish 'Plan Nacional de I+D+I del Ministerio de Ciencia e Innovacion' (TEC2011-27133-C02-01), and from the Universitat Politecnica de Valencia (PAID-06-11 Ref. 1988). A. Gonzalez-Suarez is the recipient of a Grant VaLi+D (ACIF/2011/194) from the Generalitat Valenciana, Spain. The authors alone are responsible for the content and writing of the paper. en_EN
dc.language Inglés es_ES
dc.publisher Informa Healthcare es_ES
dc.relation.ispartof International Journal of Hyperthermia es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Bipolar ablation es_ES
dc.subject Interventricular septum es_ES
dc.subject Radiofrequency ablation es_ES
dc.subject Unipolar ablation es_ES
dc.subject Ventricular ablation es_ES
dc.subject Ventricular free wall es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Radiofrequency cardiac ablation with catheters placed on opposing sides of the ventricular wall: Computer modelling comparing bipolar and unipolar modes es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3109/02656736.2014.949878
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//TEC2011-27133-C02-01/ES/MODELADO TEORICO Y EXPERIMENTACION PARA TECNICAS ABLATIVAS BASADAS EN ENERGIAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//PAID-06-11-1988/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACIF%2F2011%2F194/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation González Suárez, A.; Trujillo Guillen, M.; Koruth, J.; D'avila, A.; Berjano, E. (2014). Radiofrequency cardiac ablation with catheters placed on opposing sides of the ventricular wall: Computer modelling comparing bipolar and unipolar modes. International Journal of Hyperthermia. 30(6):372-384. https://doi.org/10.3109/02656736.2014.949878 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.3109/02656736.2014.949878 es_ES
dc.description.upvformatpinicio 372 es_ES
dc.description.upvformatpfin 384 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 30 es_ES
dc.description.issue 6 es_ES
dc.relation.senia 271598
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.description.references SIVAGANGABALAN, G., BARRY, M. A., HUANG, K., LU, J., POULIOPOULOS, J., THOMAS, S. P., … KOVOOR, P. (2010). Bipolar Ablation of the Interventricular Septum is More Efficient at Creating a Transmural Line than Sequential Unipolar Ablation. Pacing and Clinical Electrophysiology, 33(1), 16-26. doi:10.1111/j.1540-8159.2009.02602.x es_ES
dc.description.references Nagashima, K., Watanabe, I., Okumura, Y., Ohkubo, K., Kofune, M., Ohya, T., … Hirayama, A. (2011). Lesion Formation by Ventricular Septal Ablation With Irrigated Electrodes. Circulation Journal, 75(3), 565-570. doi:10.1253/circj.cj-10-0870 es_ES
dc.description.references D’ Avila, A., Houghtaling, C., Gutierrez, P., Vragovic, O., Ruskin, J. N., Josephson, M. E., & Reddy, V. Y. (2004). Catheter Ablation of Ventricular Epicardial Tissue. Circulation, 109(19), 2363-2369. doi:10.1161/01.cir.0000128039.87485.0b es_ES
dc.description.references Dukkipati, S. R., d’ Avila, A., Soejima, K., Bala, R., Inada, K., Singh, S., … Reddy, V. Y. (2011). Long-Term Outcomes of Combined Epicardial and Endocardial Ablation of Monomorphic Ventricular Tachycardia Related to Hypertrophic Cardiomyopathy. Circulation: Arrhythmia and Electrophysiology, 4(2), 185-194. doi:10.1161/circep.110.957290 es_ES
dc.description.references Sosa, E., Scanavacca, M., d’ Avila, A., Oliveira, F., & Ramires, J. A. F. (2000). Nonsurgical transthoracic epicardial catheter ablation to treat recurrent ventricular tachycardia occurring late after myocardial infarction. Journal of the American College of Cardiology, 35(6), 1442-1449. doi:10.1016/s0735-1097(00)00606-9 es_ES
dc.description.references Nagashima, K., Watanabe, I., Okumura, Y., Sonoda, K., Kofune, M., Mano, H., … Hirayama, A. (2012). Epicardial Ablation With Irrigated Electrodes. Circulation Journal, 76(2), 322-327. doi:10.1253/circj.cj-11-0984 es_ES
dc.description.references Berjano, E. J. (2006). BioMedical Engineering OnLine, 5(1), 24. doi:10.1186/1475-925x-5-24 es_ES
dc.description.references Abraham, J. P., & Sparrow, E. M. (2007). A thermal-ablation bioheat model including liquid-to-vapor phase change, pressure- and necrosis-dependent perfusion, and moisture-dependent properties. International Journal of Heat and Mass Transfer, 50(13-14), 2537-2544. doi:10.1016/j.ijheatmasstransfer.2006.11.045 es_ES
dc.description.references Jo, B., & Aksan, A. (2010). Prediction of the extent of thermal damage in the cornea during conductive keratoplasty. Journal of Thermal Biology, 35(4), 167-174. doi:10.1016/j.jtherbio.2010.02.004 es_ES
dc.description.references HAINES, D. E., & WATSON, D. D. (1989). Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free Wall. Pacing and Clinical Electrophysiology, 12(6), 962-976. doi:10.1111/j.1540-8159.1989.tb05034.x es_ES
dc.description.references Zhao, G., Zhang, H.-F., Guo, X.-J., Luo, D.-W., & Gao, D.-Y. (2007). Effect of blood flow and metabolism on multidimensional heat transfer during cryosurgery. Medical Engineering & Physics, 29(2), 205-215. doi:10.1016/j.medengphy.2006.03.005 es_ES
dc.description.references Chang, I. A., & Nguyen, U. D. (2004). BioMedical Engineering OnLine, 3(1), 27. doi:10.1186/1475-925x-3-27 es_ES
dc.description.references Whitney, J., Carswell, W., & Rylander, N. (2013). Arrhenius parameter determination as a function of heating method and cellular microenvironment based on spatial cell viability analysis. International Journal of Hyperthermia, 29(4), 281-295. doi:10.3109/02656736.2013.802375 es_ES
dc.description.references Pearce, J. A. (2013). Comparative analysis of mathematical models of cell death and thermal damage processes. International Journal of Hyperthermia, 29(4), 262-280. doi:10.3109/02656736.2013.786140 es_ES
dc.description.references Doss, J. D. (1982). Calculation of electric fields in conductive media. Medical Physics, 9(4), 566-573. doi:10.1118/1.595107 es_ES
dc.description.references Watanabe, I., Nuo, M., Okumura, Y., Ohkubo, K., Ashino, S., Kofune, M., … Hirayama, A. (2010). Temperature-Controlled Cooled-Tip Radiofrequency Ablation in Left Ventricular Myocardium. International Heart Journal, 51(3), 193-198. doi:10.1536/ihj.51.193 es_ES
dc.description.references Yokoyama, K., Nakagawa, H., Wittkampf, F. H. M., Pitha, J. V., Lazzara, R., & Jackman, W. M. (2006). Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam Pop. Circulation, 113(1), 11-19. doi:10.1161/circulationaha.105.540062 es_ES
dc.description.references Kumar, P., Mounsey, J. P., Gehi, A. K., Schwartz, J. D., & Chung, E. H. (2013). Use of a closed loop irrigated catheter in epicardial ablation of ventricular tachycardia. Journal of Interventional Cardiac Electrophysiology, 38(1), 35-42. doi:10.1007/s10840-013-9799-1 es_ES
dc.description.references Schutt, D., Berjano, E. J., & Haemmerich, D. (2009). Effect of electrode thermal conductivity in cardiac radiofrequency catheter ablation: A computational modeling study. International Journal of Hyperthermia, 25(2), 99-107. doi:10.1080/02656730802563051 es_ES
dc.description.references Gopalakrishnan, J. (2002). A Mathematical Model for Irrigated Epicardial Radiofrequency Ablation. Annals of Biomedical Engineering, 30(7), 884-893. doi:10.1114/1.1507845 es_ES
dc.description.references Suárez, A. G., Hornero, F., & Berjano, E. J. (2010). Mathematical Modeling of Epicardial RF Ablation of Atrial Tissue with Overlying Epicardial Fat. The Open Biomedical Engineering Journal, 4(1), 47-55. doi:10.2174/1874120701004020047 es_ES
dc.description.references Haemmerich, D., Chachati, L., Wright, A. S., Mahvi, D. M., Lee, F. T., & Webster, J. G. (2003). Hepatic radiofrequency ablation with internally cooled probes: effect of coolant temperature on lesion size. IEEE Transactions on Biomedical Engineering, 50(4), 493-500. doi:10.1109/tbme.2003.809488 es_ES
dc.description.references Koruth, J. S., Dukkipati, S., Miller, M. A., Neuzil, P., d’ Avila, A., & Reddy, V. Y. (2012). Bipolar irrigated radiofrequency ablation: A therapeutic option for refractory intramural atrial and ventricular tachycardia circuits. Heart Rhythm, 9(12), 1932-1941. doi:10.1016/j.hrthm.2012.08.001 es_ES
dc.description.references González-Suárez, A., Trujillo, M., Burdío, F., Andaluz, A., & Berjano, E. (2012). Feasibility study of an internally cooled bipolar applicator for RF coagulation of hepatic tissue: Experimental and computational study. International Journal of Hyperthermia, 28(7), 663-673. doi:10.3109/02656736.2012.716900 es_ES
dc.description.references Agah, R., Gandjbakhche, A. H., Motamedi, M., Nossal, R., & Bonner, R. F. (1996). Dynamics of temperature dependent optical properties of tissue: dependence on thermally induced alteration. IEEE Transactions on Biomedical Engineering, 43(8), 839-846. doi:10.1109/10.508546 es_ES
dc.description.references Haines, D. E. (2011). Letter by Haines Regarding Article, «Direct Measurement of the Lethal Isotherm for Radiofrequency Ablation of Myocardial Tissue». Circulation: Arrhythmia and Electrophysiology, 4(5). doi:10.1161/circep.111.965459 es_ES
dc.description.references Wood, M., Goldberg, S., Lau, M., Goel, A., Alexander, D., Han, F., & Feinstein, S. (2011). Direct Measurement of the Lethal Isotherm for Radiofrequency Ablation of Myocardial Tissue. Circulation: Arrhythmia and Electrophysiology, 4(3), 373-378. doi:10.1161/circep.110.961169 es_ES
dc.description.references Jain, M. K., & Wolf, P. D. (2000). A Three-Dimensional Finite Element Model of Radiofrequency Ablation with Blood Flow and its Experimental Validation. Annals of Biomedical Engineering, 28(9), 1075-1084. doi:10.1114/1.1310219 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem