Sistema biosensor de bajo coste para el diagnóstico de malaria

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Sistema biosensor de bajo coste para el diagnóstico de malaria

Show simple item record

Files in this item

dc.contributor.advisor Morais Ezquerro, Sergi Beñat es_ES
dc.contributor.author Hernández Díaz, Sara es_ES
dc.date.accessioned 2015-01-19T07:56:35Z
dc.date.available 2015-01-19T07:56:35Z
dc.date.created 2014-09-01
dc.date.issued 2015-01-19T07:56:35Z
dc.identifier.uri http://hdl.handle.net/10251/46165
dc.description.abstract [ES] Aproximadamente la mitad de la población mundial corre el riesgo de contraer la malaria, y se calcula que en 2010 hubo 219 millones de casos. Detener y comenzar a reducir, en 2015, la incidencia de la malaria y otras enfermedades graves es una de las metas de uno de los Objetivos de Desarrollo del Milenio. La prevención y control de la infección es el modo de abordar esta meta. Estas acciones se ven facilitadas especialmente en los países de bajos ingresos, si se dispone de herramientas de diagnóstico de bajo coste, sensibles y selectivos. En este sentido, la tecnología de disco compacto presenta las capacidades que la hacen idónea para abordar el desarrollo de tests de diagnóstico con características para su aplicación en países en vías de desarrollo. En este trabajo se plantea el desarrollo de un biosensor de bajo coste basado en tecnología de disco compacto para determinar la infección por malaria en suero sanguíneo humano. El sistema sensor se basa en la determinación de HRP2 del parásito Plasmodium falciparum, principal causante de la malaria. En este estudio se describe la optimización del ensayo sándwich en formato microarray sobre un disco compacto. La evaluación y optimización de las variables críticas del ensayo como tampón de impresión, concentración de anticuerpo de captura y de detección, tipo de marcaje, composición del medio de reacción, tiempo de ensayo, etc. ha permitido desarrollar un ensayo sensible y selectivo para detectar malaria en suero humano en tiempos cortos (70 minutos) y a costes bajos (<0,5 €/muestra). es_ES
dc.description.abstract [EN] Aproximately half of the world population runs the risk of contracting malaria and it has been calculated that in 2010 there were 219 million of cases. Stopping and begin to reduce, in 2015, the malaria incidence and other severe diseases is one of the goals of the Millenium Development Aims. Prevention and control of the infection is the way to adress this goal. These actions are facilitated especially in low-incomes countries, if low cost, sensitive and selective tools are available. In this way, the compact disc technology presents the capability that makes it ideal for approach the diagnostic tests development with characteristics for its application in countries in process of development. In this work has been raised the development of a low-cost biosensor based in compact disc technology in order to determine the malaria infection in blood serum. The sensor system consists in the Plasmodium falciparum parasite protein HRP2 determination, the main causative of malaria. In this study it's described the optimization of the sandwich assay for the microarray format on a compact disc. The evaluation and optimization of the assay's critical variables as the print buffer, capture and detection antibody concentration, kind of labeling, reaction medium composition, assay times... etc has allowed the development of a sensitive and selective assay able to detect malaria in human serum in shorter times (70 minutes) and low-costs (<0,5 €/sample es_ES
dc.format.extent 27 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Tecnología de disco compacto es_ES
dc.subject Inmunoensayo es_ES
dc.subject Mosquito Anopheles es_ES
dc.subject Proteina HRp2 es_ES
dc.subject Antigenos es_ES
dc.subject Anticuerpos es_ES
dc.subject compact disc technology es_ES
dc.subject Inmunoassay es_ES
dc.subject Biosensor es_ES
dc.subject Plasmodium falciparum es_ES
dc.subject Anopheles mosquitoe es_ES
dc.subject HRP2 protein es_ES
dc.subject Antigens es_ES
dc.subject Antibodies es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.subject.other Grado en Biotecnología-Grau en Biotecnologia es_ES
dc.title Sistema biosensor de bajo coste para el diagnóstico de malaria es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior del Medio Rural y Enología - Escola Tècnica Superior del Medi Rural i Enologia es_ES
dc.description.bibliographicCitation Hernández Díaz, S. (2014). Sistema biosensor de bajo coste para el diagnóstico de malaria. http://hdl.handle.net/10251/46165. es_ES
dc.description.accrualMethod Archivo delegado es_ES


This item appears in the following Collection(s)

Show simple item record