Mostrar el registro sencillo del ítem
dc.contributor.advisor | Morais Ezquerro, Sergi Beñat | es_ES |
dc.contributor.advisor | Tortajada Genaro, Luis Antonio | es_ES |
dc.contributor.author | Marsavela, Anda Gabriela | es_ES |
dc.date.accessioned | 2015-07-16T14:17:22Z | |
dc.date.available | 2015-07-16T14:17:22Z | |
dc.date.created | 2014-12-19 | |
dc.date.issued | 2015-07-16 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/53327 | |
dc.description.abstract | [EN] The amoxicillin is one of the most beta-lactam antibiotics frequently involved in allergic reactions to pharmaceutical drugs. The current diagnostic techniques are based on in vivo tests, which are invasive and aggressive for the patients. Hence, the need arises to develop new diagnostic techniques more subtle that allow to quickly and easily detect the drug responsible for the allergic reaction. The intention of this project is to contribute to the development of a minimally intrusive in vitro assay. The technique is based on the detection and quantification of total IgEs and specific to amoxicillin IgEs using magnetic particles conjugated to anti-IgE antibodies. This methodology uses CD technology, creating a protein microarray with specific drug-protein conjugates for the detection of specific IgEs, and anti-IgE antibodies for total IgEs quantification. | es_ES |
dc.description.abstract | [ES] La amoxicilina es uno de los antibióticos betalactámicos más frecuentemente implicado en las reacciones alérgicas a fármacos. Las técnicas actuales de diagnóstico están basadas en ensayos in vivo, invasivos per se y agresivos para el paciente. Por ello, existe la necesidad de desarrollar nuevos métodos de diagnóstico, más sensibles que permitan una asignación rápida y sencilla del medicamento causante de la alergia. Este trabajo pretende contribuir al desarrollo de un ensayo in vitro mínimamente invasivo, basado en la detección y cuantificación de IgEs totales y específicas para amoxicilina utilizando partículas magnéticas conjugadas a anticuerpos anti-IgE. El método se basa en la tecnología de disco compacto, siguiendo un formato de micromatriz de proteínas utilizando conjugados específicos fármaco-proteína para la detección de IgEs específicas y anticuerpos anti-IgE para la cuantificación de IgEs totales. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Allergy | es_ES |
dc.subject | β-lactams | es_ES |
dc.subject | Amoxicillin | es_ES |
dc.subject | Magnetic particles | es_ES |
dc.subject | Microarray. | es_ES |
dc.subject | Alergia | es_ES |
dc.subject | β-lactámicos | es_ES |
dc.subject | Amoxicilina | es_ES |
dc.subject | Partículas magnéticas | es_ES |
dc.subject | IgEs | es_ES |
dc.subject | Micromatriz | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.subject.other | Grado en Biotecnología-Grau en Biotecnologia | es_ES |
dc.title | Síntesis y caracterización de reactivos para el diagnóstico de alergia a amoxicilina | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural | es_ES |
dc.description.bibliographicCitation | Marsavela, AG. (2014). SÍNTESIS Y CARACTERIZACIÓN DE REACTIVOS PARA EL DIAGNÓSTICO DE ALERGIA A AMOXICILINA. http://hdl.handle.net/10251/53327. | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\21005 | es_ES |