dc.description.abstract | In this study we propose an electronic system for linear positioning of a magnet independent of its modulus, which could vary because of aging, different fabrication process, etc. The system comprises a linear array of 24 Hall Effect sensors of proportional response. The data from all sensors are subject to a pretreatment (normalization) by row (position) making them independent on the temporary variation of its magnetic field strength. We analyze the particular case of the individual flow in milking of goats. The multiple regression analysis allowed us to calibrate the electronic system with a percentage of explanation R-2 = 99.96%. In our case, the uncertainty in the linear position of the magnet is 0.51 mm that represents 0.019 L of goat milk. The test in farm compared the results obtained by direct reading of the volume with those obtained by the proposed electronic calibrated system, achieving a percentage of explanation of 99.05%. | es_ES |
dc.description.sponsorship | This work was partially supported by the Spanish Government (Ministerio de Ciencia e Innovacion) under projects HAR2010-21944-C02-01 and HAR2010-21944-C02-02. A. Sanchez-Quinche acknowledges the support received from SENESCYT (Secretaria Nacional de Educacion Superior, Ciencia, Tecnologia e Innovacion) from the Equator Republic. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Sensors | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Hall effect sensors | es_ES |
dc.subject | milk yield | es_ES |
dc.subject | multiple regression | es_ES |
dc.subject | linear magnet position | es_ES |
dc.subject.classification | PRODUCCION ANIMAL | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Array of Hall Effect Sensors for Linear Positioning of a Magnet Independently of Its Strength Variation. A Case Study: Monitoring Milk Yield during Milking in Goats | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/s130608000 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//HAR2010-21944-C02-01/ES/CARACTERIZACION MICROCLIMATICA DE OBRAS DE ARTE ENFOCADA A LA CONSERVACION PREVENTIVA DE LAS MISMAS/ / | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//HAR2010-21944-C02-02/ES/MONITORIZACION Y ESTUDIO DE DEGRADACION EN OBRAS DE ARTE ENFOCADO A LA CONSERVACION PREVENTIVA DE LAS MISMAS./ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal | es_ES |
dc.description.bibliographicCitation | García Diego, FJ.; Sanchez-Quinche, A.; Merello Giménez, P.; Beltrán Medina, P.; Peris Ribera, CJ. (2013). Array of Hall Effect Sensors for Linear Positioning of a Magnet Independently of Its Strength Variation. A Case Study: Monitoring Milk Yield during Milking in Goats. Sensors. 13(6):8000-8012. doi:10.3390/s130608000 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.3390/s130608000 | es_ES |
dc.description.upvformatpinicio | 8000 | es_ES |
dc.description.upvformatpfin | 8012 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 13 | es_ES |
dc.description.issue | 6 | es_ES |
dc.relation.senia | 246445 | es_ES |
dc.identifier.pmid | 23793020 | en_EN |
dc.identifier.pmcid | PMC3715257 | en_EN |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Secretaría de Educación Superior, Ciencia, Tecnología e Innovación, Ecuador | es_ES |
dc.description.references | RICORDEAU, G., MARTINET, J., DENAMUR, R., PETREQUIN, P., & CARPENTIER, M. (1963). TRAITE A LA MACHINE DES BREBIS PRÉALPES DU SUD. IMPORTANCE DES DIFFÉRENTES OPÉRATIONS DE LA TRAITE. Annales de Zootechnie, 12(3), 203-223. doi:10.1051/animres:19630305 | es_ES |
dc.description.references | Barillet, F. (2007). Genetic improvement for dairy production in sheep and goats. Small Ruminant Research, 70(1), 60-75. doi:10.1016/j.smallrumres.2007.01.004 | es_ES |
dc.description.references | Ilahi, H., Chastin, P., Bouvier, F., Arhainx, J., Ricard, E., & Manfredi, E. (1999). Milking characteristics of dairy goats. Small Ruminant Research, 34(2), 97-102. doi:10.1016/s0921-4488(99)00057-7 | es_ES |
dc.description.references | Ait-Saidi, A., Caja, G., Carné, S., Salama, A. A. K., & Ghirardi, J. J. (2008). Short Communication: Comparison of Manual Versus Semiautomatic Milk Recording Systems in Dairy Goats. Journal of Dairy Science, 91(4), 1438-1442. doi:10.3168/jds.2007-0815 | es_ES |
dc.description.references | Nishio, T., Chen, Q., Gillijns, W., De Keyser, K., Vervaeke, K., & Moshchalkov, V. V. (2008). Scanning Hall probe microscopy of vortex patterns in a superconducting microsquare. Physical Review B, 77(1). doi:10.1103/physrevb.77.012502 | es_ES |
dc.description.references | Kim, J., Lee, J., Jun, J., Le, M., & Cho, C. (2012). Integration of Hall and Giant Magnetoresistive Sensor Arrays for Real-Time 2-D Visualization of Magnetic Field Vectors. IEEE Transactions on Magnetics, 48(11), 3708-3711. doi:10.1109/tmag.2012.2200662 | es_ES |
dc.description.references | Benitez, D., Gaydecki, P., Quek, S., & Torres, V. (2007). Development of a solid-state multi-sensor array camera for real time imaging of magnetic fields. Journal of Physics: Conference Series, 76, 012030. doi:10.1088/1742-6596/76/1/012030 | es_ES |
dc.description.references | Misron, N., Shin, N. W., Shafie, S., Marhaban, M. H., & Mailah, N. F. (2011). A Mobile Ferromagnetic Shape Detection Sensor Using a Hall Sensor Array and Magnetic Imaging. Sensors, 11(11), 10474-10489. doi:10.3390/s111110474 | es_ES |
dc.description.references | http://www.allegromicro.com/˜/media/Files/Datasheets/A1301–2-Datasheet.ashx | es_ES |
dc.description.references | http://www.Arduino.cc | es_ES |
dc.description.references | http://www.supermagnete.es/R-27–16–05-N | es_ES |
dc.description.references | Ravaud, R., Lemarquand, G., Lemarquand, V., & Depollier, C. (2008). THE THREE EXACT COMPONENTS OF THE MAGNETIC FIELD CREATED BY A RADIALLY MAGNETIZED TILE PERMANENT MAGNET. Progress In Electromagnetics Research, 88, 307-319. doi:10.2528/pier08112708 | es_ES |
dc.description.references | Gallagher, N. B., Wise, B. M., & Stewart, C. W. (1996). Application of multi-way principal components analysis to nuclear waste storage tank monitoring. Computers & Chemical Engineering, 20, S739-S744. doi:10.1016/0098-1354(96)00131-7 | es_ES |
dc.description.references | Rännar, S., MacGregor, J. F., & Wold, S. (1998). Adaptive batch monitoring using hierarchical PCA. Chemometrics and Intelligent Laboratory Systems, 41(1), 73-81. doi:10.1016/s0169-7439(98)00024-0 | es_ES |
dc.description.references | Zarzo, M., & Ferrer, A. (2004). Batch process diagnosis: PLS with variable selection versus block-wise PCR. Chemometrics and Intelligent Laboratory Systems, 73(1), 15-27. doi:10.1016/j.chemolab.2003.11.009 | es_ES |
dc.description.references | García-Diego, F.-J., & Zarzo, M. (2010). Microclimate monitoring by multivariate statistical control: The renaissance frescoes of the Cathedral of Valencia (Spain). Journal of Cultural Heritage, 11(3), 339-344. doi:10.1016/j.culher.2009.06.002 | es_ES |
dc.description.references | Zarzo, M., Fernández-Navajas, A., & García-Diego, F.-J. (2011). Long-Term Monitoring of Fresco Paintings in the Cathedral of Valencia (Spain) Through Humidity and Temperature Sensors in Various Locations for Preventive Conservation. Sensors, 11(9), 8685-8710. doi:10.3390/s110908685 | es_ES |
dc.description.references | Statgraphics 5.1http://www.statgraphics.net | es_ES |