- -

Estudio de Eficiencia Energetica de una Vivienda unifamiliar entremedianeras en Xirivella

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio de Eficiencia Energetica de una Vivienda unifamiliar entremedianeras en Xirivella

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Pascual Galan, Amadeo es_ES
dc.contributor.author Belhouari, Khaled es_ES
dc.date.accessioned 2016-02-05T19:24:55Z
dc.date.available 2016-02-05T19:24:55Z
dc.date.created 2015-12-15
dc.date.issued 2016-02-05 es_ES
dc.identifier.uri http://hdl.handle.net/10251/60666
dc.description.abstract [ES] El PFG se trata de un estudio de eficiencia energética de una vivienda unifamiliar existente. Esta vivienda está ubicada en el Sur de Xirivella, Valencia. Nuestro estudio analizará el comportamiento energético de nuestra vivienda partiendo de los elementos que la constituyen. Ya sabemos que su rendimiento energético no va a ser eficiente por lo que va a ser sometida a cambios y remodelaciones de su envolvente que debería haberse tomado en su día. Intentaremos que nuestra vivienda consuma menos y por tanto va a provocar la reducción de las emisiones nocivas a la atmosfera. Al mismo tiempo nos va a paliar la economía de nuestros bolsillos. Éste estudio requiere herramientas informáticas especiales para llevarlo a cabo, como la utilización de programas que diagnostican la eficiencia energética de una vivienda. Programas como CE3x reconocido y promovido por El Ministerio de Industria, Energía y Turismo a través de la IDAE (INSTITUTO PARA LA DIVERSIFICACIÓN Y AHOROO DE LA ENERGIA) va a ser la autora para la calificación de eficiencia energética de Edificios unifamiliares. El Código Técnico de Edificación (CTE) obliga el uso de éste programa CE3X para justificar el Nuevo Documento del CTE (DBHE) en las secciones Limitaciones del Consumo Energético(HE0) Limitaciones del Demanda Energética(HE1) en Calificación de Certificación de Eficiencia Energética en siguientes condiciones: nueva construcción, ampliación, reforma, cambio de uso, edificaciones existentes que vayan a ponerse a la venta o alquiler y edificaciones abiertas permanentemente que estén acondicionadas (aclimatadas). Este software permite calcular las transmitancias térmicas de los cerramientos exteriores de la vivienda, así como las condensaciones intersticiales o superficiales en el caso de que hubiese, verificando así el cumplimiento del HE El primer paso es conseguir que se cumplan dichas exigencias mínimas y para ello se realizan modificaciones en cuanto a soluciones constructivas, materiales, espesores de aislamiento, modificación de los huecos, adición de sombrea miento, etc. Lo siguiente es llevar los cálculos al programa de certificación energética, para ello se puede elegir entre los programas reconocidos por la IDEA. En este caso se usa el CE3x. Este software permite calcular la demanda de refrigeración y calefacción, así como el consumo energético y las emisiones de C0₂, que son los datos necesarios para definir una calificación energética. También obliga a añadir una contribución solar mínima para la producción de ACS, asegurando así el cumplimiento del HE 4. Una vez efectuada esta calificación, se intenta mejorarla, cambiando los Equipos de calefacción y refrigeración por otros más eficientes, de Consumo más bajo y con menos emisiones de gases de efecto Invernadero. es_ES
dc.description.abstract [EN] The final Project is about the study of the energy efficiency of a one–family housing. This housing is located in Xirivella, Valencia. At first we try to obtain a housing with zero consumption, but to obtain it, a great economic initial contribution would be needed, for this reason We try to look for an average term between economy and energy efficiency. For the above mentioned study the first thing is to realize the necessary calculations to know if the housing obeys minimum requirements that the CTE demands from us in its DB-HE1, to obtain this we have to use a program called ce3X. This software allows to calculate thermal transmittance of the exterior closing of the housing, as well as the intermediate o superficial Condensations, verifying the fulfilment of the HE 1. The first step is to achieve that it fulfils the above mentioned minimal requirements and for that we have to carry out some modifications in constructive solutions, materials for building, thicknesses of isolation, modifications of doors and windows, etc. The following thing is to export these calculations to some program of energetic certification, to do this, it is possible to choose between the programs recognized by the IDEA. In this case the CEXv1 is used. This software allows to calculate the demand of refrigeration and heating, as well as the energetic consumption and the emission of C0₂, which are the necessary information to define an energetic qualification. It also obliges us to add a minimum solar contribution for ACS's production, assuring this way the fulfilment of HE 4. Once obtained this qualification we try to improve it by changing the equipment of heating and refrigeration for others more efficient, of lower consumption and with fewer emissions of greenhouse gases. es_ES
dc.format.extent 121 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Eficiencia energética es_ES
dc.subject Calificación energética es_ES
dc.subject Certificación energética es_ES
dc.subject Energía solar térmica es_ES
dc.subject Viviendas unifamiliares es_ES
dc.subject Medianeras es_ES
dc.subject Fachadas es_ES
dc.subject Cubiertas es_ES
dc.subject Energy efficiency es_ES
dc.subject Energy certification es_ES
dc.subject Energy rating es_ES
dc.subject Solar thermal energy es_ES
dc.subject Housing, Single family es_ES
dc.subject Party walls es_ES
dc.subject Façades es_ES
dc.subject Roofs es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Grado en Arquitectura Técnica-Grau en Arquitectura Tècnica es_ES
dc.title Estudio de Eficiencia Energetica de una Vivienda unifamiliar entremedianeras en Xirivella es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Gestión en la Edificación - Escola Tècnica Superior de Gestió en l'Edificació es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Belhouari, K. (2015). Estudio de Eficiencia Energetica de una Vivienda unifamiliar entremedianeras en Xirivella. http://hdl.handle.net/10251/60666. es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\39851 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem