Mostrar el registro sencillo del ítem
dc.contributor.author | Atkinson, J.K. | es_ES |
dc.contributor.author | Glanc, M. | es_ES |
dc.contributor.author | Prakorbjanya, M. | es_ES |
dc.contributor.author | Sophocleous, M. | es_ES |
dc.contributor.author | Sion, R.P. | es_ES |
dc.contributor.author | Garcia-Breijo, Eduardo | es_ES |
dc.date.accessioned | 2016-05-11T15:27:36Z | |
dc.date.available | 2016-05-11T15:27:36Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 1356-5362 | |
dc.identifier.uri | http://hdl.handle.net/10251/63936 | |
dc.description.abstract | Purpose – The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications. Design/methodology/approach – Various choices of materials for reference electrodes employed in these different applications have been evaluated and the responses of the different sensor types are compared and discussed. Findings – Results indicate that the choice of binder materials is critical to the production of sensors capable of medium term deployment (e.g. several days) as the binders not only affect the tradeoff between hydration time and drift but also have a significant bearing on device sensitivity and stability. Sensor calibration is shown to remain an issue with long-term deployments (e.g. several weeks) but this can be ameliorated in the medium term with the use of novel device fabrication and packaging techniques. Originality/value – The reported results indicate that is possible through careful choice of materials and fabrication methods to achieve near stable thick film reference electrodes that are suitable for use in solid state chemical sensors in a variety of different application areas. | es_ES |
dc.description.sponsorship | Two of the authors wish to acknowledge partial support of their studentships by the UK Environment Agency (Monika Glanc) and the UK Natural Environment Research Council (Marios Sophocleous). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Emerald | es_ES |
dc.relation.ispartof | Microelectronics International | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Sensors | es_ES |
dc.subject | Reference electrodes | es_ES |
dc.subject | Thick-film sensors | es_ES |
dc.subject | Silver/silver chloride | es_ES |
dc.subject | Environmental sensors | es_ES |
dc.subject | Electrodes | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1108/13565361311314485 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Atkinson, J.; Glanc, M.; Prakorbjanya, M.; Sophocleous, M.; Sion, R.; Garcia-Breijo, E. (2013). Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments. Microelectronics International. 30(2):92-98. doi:10.1108/13565361311314485 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1108/13565361311314485] | es_ES |
dc.description.upvformatpinicio | 92 | es_ES |
dc.description.upvformatpfin | 98 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 30 | es_ES |
dc.description.issue | 2 | es_ES |
dc.relation.senia | 258725 | es_ES |
dc.contributor.funder | Natural Environment Research Council, Reino Unido | es_ES |
dc.contributor.funder | Environment Agency, Reino Unido | es_ES |
dc.description.references | Andreescu, S. (2002). Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. Talanta, 57(1), 169-176. doi:10.1016/s0039-9140(02)00017-6 | es_ES |
dc.description.references | Atkinson, J. K., Glanc, M., Boltryk, P., Sophocleous, M., & Garcia‐Breijo, E. (2011). An investigation into the effect of fabrication parameter variation on the characteristics of screen‐printed thick‐film silver/silver chloride reference electrodes. Microelectronics International, 28(2), 49-52. doi:10.1108/13565361111127368 | es_ES |
dc.description.references | Boujtita, M. (2000). Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer. Biosensors and Bioelectronics, 15(5-6), 257-263. doi:10.1016/s0956-5663(00)00075-0 | es_ES |
dc.description.references | Cranny, A. W. J., & Atkinson, J. K. (1998). Thick film silver-silver chloride reference electrodes. Measurement Science and Technology, 9(9), 1557-1565. doi:10.1088/0957-0233/9/9/027 | es_ES |
dc.description.references | Cranny, A., Harris, N. R., Nie, M., Wharton, J. A., Wood, R. J. K., & Stokes, K. R. (2011). Screen-printed potentiometric Ag/AgCl chloride sensors: Lifetime performance and their use in soil salt measurements. Sensors and Actuators A: Physical, 169(2), 288-294. doi:10.1016/j.sna.2011.01.016 | es_ES |
dc.description.references | Gac, A., Atkinson, J. K., Zhang, Z., & Sion, R. P. (2002). A comparison of thick-film chemical sensor characteristics in laboratory and on-line industrial process applications. Measurement Science and Technology, 13(12), 2062-2073. doi:10.1088/0957-0233/13/12/335 | es_ES |
dc.description.references | Gac, A., Atkinson, J. K., Zhang, Z., Sexton, C. J., Lewis, S. M., Please, C. P., & Sion, R. (2004). Investigation of the fabrication parameters of thick film titanium oxide‐PVC pH electrodes using experimental designs. Microelectronics International, 21(3), 44-53. doi:10.1108/13565360410549710 | es_ES |
dc.description.references | Glasspool, W. V., & Atkinson, J. K. (2003). An evaluation of the characteristics of membrane materials suitable for the batch fabrication of dissolved oxygen sensors. Microelectronics International, 20(2), 32-40. doi:10.1108/13565360310472185 | es_ES |
dc.description.references | Mamińska, R., Dybko, A., & Wróblewski, W. (2006). All-solid-state miniaturised planar reference electrodes based on ionic liquids. Sensors and Actuators B: Chemical, 115(1), 552-557. doi:10.1016/j.snb.2005.10.018 | es_ES |
dc.description.references | Matsumoto, T., Ohashi, A., & Ito, N. (2002). Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor. Analytica Chimica Acta, 462(2), 253-259. doi:10.1016/s0003-2670(02)00334-3 | es_ES |
dc.description.references | Mihell, J. A., & Atkinson, J. K. (1998). Planar thick-film pH electrodes based on ruthenium dioxide hydrate. Sensors and Actuators B: Chemical, 48(1-3), 505-511. doi:10.1016/s0925-4005(98)00090-2 | es_ES |
dc.description.references | Mroz, A. (1998). Disposable reference electrode. The Analyst, 123(6), 1373-1376. doi:10.1039/a708992i | es_ES |
dc.description.references | Simonis, A., Lüth, H., Wang, J., & Schöning, M. J. (2004). New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems. Sensors and Actuators B: Chemical, 103(1-2), 429-435. doi:10.1016/j.snb.2004.04.072 | es_ES |
dc.description.references | Tymecki, Ł., Zwierkowska, E., & Koncki, R. (2004). Screen-printed reference electrodes for potentiometric measurements. Analytica Chimica Acta, 526(1), 3-11. doi:10.1016/j.aca.2004.08.056 | es_ES |
dc.description.references | Atkinson, J. K., Cranny, A. W. J., Glasspool, W. V., & Mihell, J. A. (1999). An investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters. Sensors and Actuators B: Chemical, 54(3), 215-231. doi:10.1016/s0925-4005(99)00023-4 | es_ES |