Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments

Mostrar el registro completo del ítem

Atkinson, J.; Glanc, M.; Prakorbjanya, M.; Sophocleous, M.; Sion, R.; Garcia-Breijo, E. (2013). Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments. Microelectronics International. 30(2):92-98. doi:10.1108/13565361311314485

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/63936

Ficheros en el ítem

Metadatos del ítem

Título: Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments
Autor: Atkinson, J.K. Glanc, M. Prakorbjanya, M. Sophocleous, M. Sion, R.P. Garcia-Breijo, Eduardo
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Fecha difusión:
Resumen:
Purpose – The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications. Design/methodology/approach – Various ...[+]
Palabras clave: Sensors , Reference electrodes , Thick-film sensors , Silver/silver chloride , Environmental sensors , Electrodes
Derechos de uso: Reserva de todos los derechos
Fuente:
Microelectronics International. (issn: 1356-5362 )
DOI: 10.1108/13565361311314485
Editorial:
Emerald
Versión del editor: http://dx.doi.org/10.1108/13565361311314485]
Agradecimientos:
Two of the authors wish to acknowledge partial support of their studentships by the UK Environment Agency (Monika Glanc) and the UK Natural Environment Research Council (Marios Sophocleous).
Tipo: Artículo

References

Andreescu, S. (2002). Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. Talanta, 57(1), 169-176. doi:10.1016/s0039-9140(02)00017-6

Atkinson, J. K., Glanc, M., Boltryk, P., Sophocleous, M., & Garcia‐Breijo, E. (2011). An investigation into the effect of fabrication parameter variation on the characteristics of screen‐printed thick‐film silver/silver chloride reference electrodes. Microelectronics International, 28(2), 49-52. doi:10.1108/13565361111127368

Boujtita, M. (2000). Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer. Biosensors and Bioelectronics, 15(5-6), 257-263. doi:10.1016/s0956-5663(00)00075-0 [+]
Andreescu, S. (2002). Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. Talanta, 57(1), 169-176. doi:10.1016/s0039-9140(02)00017-6

Atkinson, J. K., Glanc, M., Boltryk, P., Sophocleous, M., & Garcia‐Breijo, E. (2011). An investigation into the effect of fabrication parameter variation on the characteristics of screen‐printed thick‐film silver/silver chloride reference electrodes. Microelectronics International, 28(2), 49-52. doi:10.1108/13565361111127368

Boujtita, M. (2000). Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer. Biosensors and Bioelectronics, 15(5-6), 257-263. doi:10.1016/s0956-5663(00)00075-0

Cranny, A. W. J., & Atkinson, J. K. (1998). Thick film silver-silver chloride reference electrodes. Measurement Science and Technology, 9(9), 1557-1565. doi:10.1088/0957-0233/9/9/027

Cranny, A., Harris, N. R., Nie, M., Wharton, J. A., Wood, R. J. K., & Stokes, K. R. (2011). Screen-printed potentiometric Ag/AgCl chloride sensors: Lifetime performance and their use in soil salt measurements. Sensors and Actuators A: Physical, 169(2), 288-294. doi:10.1016/j.sna.2011.01.016

Gac, A., Atkinson, J. K., Zhang, Z., & Sion, R. P. (2002). A comparison of thick-film chemical sensor characteristics in laboratory and on-line industrial process applications. Measurement Science and Technology, 13(12), 2062-2073. doi:10.1088/0957-0233/13/12/335

Gac, A., Atkinson, J. K., Zhang, Z., Sexton, C. J., Lewis, S. M., Please, C. P., & Sion, R. (2004). Investigation of the fabrication parameters of thick film titanium oxide‐PVC pH electrodes using experimental designs. Microelectronics International, 21(3), 44-53. doi:10.1108/13565360410549710

Glasspool, W. V., & Atkinson, J. K. (2003). An evaluation of the characteristics of membrane materials suitable for the batch fabrication of dissolved oxygen sensors. Microelectronics International, 20(2), 32-40. doi:10.1108/13565360310472185

Mamińska, R., Dybko, A., & Wróblewski, W. (2006). All-solid-state miniaturised planar reference electrodes based on ionic liquids. Sensors and Actuators B: Chemical, 115(1), 552-557. doi:10.1016/j.snb.2005.10.018

Matsumoto, T., Ohashi, A., & Ito, N. (2002). Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor. Analytica Chimica Acta, 462(2), 253-259. doi:10.1016/s0003-2670(02)00334-3

Mihell, J. A., & Atkinson, J. K. (1998). Planar thick-film pH electrodes based on ruthenium dioxide hydrate. Sensors and Actuators B: Chemical, 48(1-3), 505-511. doi:10.1016/s0925-4005(98)00090-2

Mroz, A. (1998). Disposable reference electrode. The Analyst, 123(6), 1373-1376. doi:10.1039/a708992i

Simonis, A., Lüth, H., Wang, J., & Schöning, M. J. (2004). New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems. Sensors and Actuators B: Chemical, 103(1-2), 429-435. doi:10.1016/j.snb.2004.04.072

Tymecki, Ł., Zwierkowska, E., & Koncki, R. (2004). Screen-printed reference electrodes for potentiometric measurements. Analytica Chimica Acta, 526(1), 3-11. doi:10.1016/j.aca.2004.08.056

Atkinson, J. K., Cranny, A. W. J., Glasspool, W. V., & Mihell, J. A. (1999). An investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters. Sensors and Actuators B: Chemical, 54(3), 215-231. doi:10.1016/s0925-4005(99)00023-4

[-]

recommendations

 