Mostrar el registro sencillo del ítem
dc.contributor.author | Iborra Carreres, Amadeo | es_ES |
dc.contributor.author | Rodríguez Álvarez, María José | es_ES |
dc.contributor.author | Soriano Asensi, Antonio | es_ES |
dc.contributor.author | Sanchez, F. | es_ES |
dc.contributor.author | Bellido, P. | es_ES |
dc.contributor.author | Conde Castellanos, Pablo Eloy | es_ES |
dc.contributor.author | Crespo Navarro, Efren | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Moliner Martínez, Laura | es_ES |
dc.contributor.author | Rigla Pérez, Juan Pablo | es_ES |
dc.contributor.author | Seimetz, Michael | es_ES |
dc.contributor.author | Vidal San Sebastián, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.date.accessioned | 2016-05-13T11:50:50Z | |
dc.date.available | 2016-05-13T11:50:50Z | |
dc.date.issued | 2015-06 | |
dc.identifier.issn | 0018-9499 | |
dc.identifier.uri | http://hdl.handle.net/10251/64026 | |
dc.description | “©2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.” | es_ES |
dc.description.abstract | In this paper, the noise of 3D computed tomography (CT) image reconstruction using QR-Decomposition is analyzed. There are several types of image noise that can interfere with the interpretation of an image. Here, the noise introduced by the reconstruction process is studied. In this analysis, condition numbers are calculated with different CT model parameters, three dimensional (3D) CT image reconstruction with simulated and real data are performed, image noise analysis is performed through various image quality parameters and the condition number of the linear system is related with the image quality parameters. Results show the condition number’s dependence on the CT model. Image reconstructions with simulated data show errors significantly below the condition number theoretical bound and image reconstructions with real data show that quality improvements depend strongly on the condition number. This allows a reduction on the number of projections without compromising image quality and places this reconstruction method as a strong candidate for low-dose 3D CT imaging reconstruction. | es_ES |
dc.description.sponsorship | This work was supported in part by the Spanish Goverment grant RTC-2014-2065-2 and the Valencian Local Government grants PROMETEOII/2013/010 and ISIC 2011/013. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | es_ES |
dc.relation.ispartof | IEEE Transactions on Nuclear Science | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | CT image reconstruction | es_ES |
dc.subject | CT low dose imaging | es_ES |
dc.subject | CT modeling | es_ES |
dc.subject | Image noise | es_ES |
dc.subject | Inverse problem | es_ES |
dc.subject | Medical imaging | es_ES |
dc.subject | QR decomposition | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1109/TNS.2015.2422213 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//RTC-2014-2065-2Q4618002BC.VALENCIANA/ES/Desarrollo de una Tecnología avanzada de detección de materias extrañas y perfil de texturas en el interior de alimentos - INSIDEFOOD/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//ISIC%2F2011%2F013/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.description.bibliographicCitation | Iborra Carreres, A.; Rodríguez Álvarez, MJ.; Soriano Asensi, A.; Sanchez, F.; Bellido, P.; Conde Castellanos, PE.; Crespo Navarro, E.... (2015). Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm. IEEE Transactions on Nuclear Science. 62(3):869-875. https://doi.org/10.1109/TNS.2015.2422213 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/ 10.1109/TNS.2015.2422213 | es_ES |
dc.description.upvformatpinicio | 869 | es_ES |
dc.description.upvformatpfin | 875 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 62 | es_ES |
dc.description.issue | 3 | es_ES |
dc.relation.senia | 291645 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |