Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Iborra Carreres, Amadeo es_ES
dc.contributor.author Rodríguez Álvarez, María José es_ES
dc.contributor.author Soriano Asensi, Antonio es_ES
dc.contributor.author Sanchez, F. es_ES
dc.contributor.author Bellido, P. es_ES
dc.contributor.author Conde Castellanos, Pablo Eloy es_ES
dc.contributor.author Crespo Navarro, Efren es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Moliner Martínez, Laura es_ES
dc.contributor.author Rigla Pérez, Juan Pablo es_ES
dc.contributor.author Seimetz, Michael es_ES
dc.contributor.author Vidal San Sebastián, Luis Fernando es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.date.accessioned 2016-05-13T11:50:50Z
dc.date.available 2016-05-13T11:50:50Z
dc.date.issued 2015-06
dc.identifier.issn 0018-9499
dc.identifier.uri http://hdl.handle.net/10251/64026
dc.description “©2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.” es_ES
dc.description.abstract In this paper, the noise of 3D computed tomography (CT) image reconstruction using QR-Decomposition is analyzed. There are several types of image noise that can interfere with the interpretation of an image. Here, the noise introduced by the reconstruction process is studied. In this analysis, condition numbers are calculated with different CT model parameters, three dimensional (3D) CT image reconstruction with simulated and real data are performed, image noise analysis is performed through various image quality parameters and the condition number of the linear system is related with the image quality parameters. Results show the condition number’s dependence on the CT model. Image reconstructions with simulated data show errors significantly below the condition number theoretical bound and image reconstructions with real data show that quality improvements depend strongly on the condition number. This allows a reduction on the number of projections without compromising image quality and places this reconstruction method as a strong candidate for low-dose 3D CT imaging reconstruction. es_ES
dc.description.sponsorship This work was supported in part by the Spanish Goverment grant RTC-2014-2065-2 and the Valencian Local Government grants PROMETEOII/2013/010 and ISIC 2011/013. en_EN
dc.language Inglés es_ES
dc.publisher Institute of Electrical and Electronics Engineers (IEEE) es_ES
dc.relation.ispartof IEEE Transactions on Nuclear Science es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject CT image reconstruction es_ES
dc.subject CT low dose imaging es_ES
dc.subject CT modeling es_ES
dc.subject Image noise es_ES
dc.subject Inverse problem es_ES
dc.subject Medical imaging es_ES
dc.subject QR decomposition es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.title Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1109/TNS.2015.2422213
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//RTC-2014-2065-2Q4618002BC.VALENCIANA/ES/Desarrollo de una Tecnología avanzada de detección de materias extrañas y perfil de texturas en el interior de alimentos - INSIDEFOOD/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2013%2F010/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ISIC%2F2011%2F013/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.description.bibliographicCitation Iborra Carreres, A.; Rodríguez Álvarez, MJ.; Soriano Asensi, A.; Sanchez, F.; Bellido, P.; Conde Castellanos, PE.; Crespo Navarro, E.... (2015). Noise Analysis in Computed Tomography (CT) Image Reconstruction using QR-Decomposition Algorithm. IEEE Transactions on Nuclear Science. 62(3):869-875. https://doi.org/10.1109/TNS.2015.2422213 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/ 10.1109/TNS.2015.2422213 es_ES
dc.description.upvformatpinicio 869 es_ES
dc.description.upvformatpfin 875 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 62 es_ES
dc.description.issue 3 es_ES
dc.relation.senia 291645 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem