Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

Show full item record

Percoco, G.; Sánchez Salmerón, AJ. (2015). Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view. Measurement Science and Technology. 26(9):1-9. doi:10.1088/0957-0233/26/9/095203

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/65169

Files in this item

Item Metadata

Title: Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view
Author: Percoco, Gianluca Sánchez Salmerón, Antonio José
UPV Unit: Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica
Issued date:
Abstract:
The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the ...[+]
Subjects: Measuremen , Digital close-range photogrammetry , Camera calibration , Microfeatures , Vision inspection , Digital image processing , Open-source
Copyrigths: Reconocimiento (by)
Source:
Measurement Science and Technology. (issn: 0957-0233 )
DOI: 10.1088/0957-0233/26/9/095203
Publisher:
IOP Publishing: Hybrid Open Access
Publisher version: http://dx.doi.org/10.1088/0957-0233/26/9/095203
Type: Artículo

References

Mitchell, H. L., Kniest, H. T., & Won‐Jin, O. (1999). Digital Photogrammetry and Microscope Photographs. The Photogrammetric Record, 16(94), 695-704. doi:10.1111/0031-868x.00148

Chen, Z., Liao, H., & Zhang, X. (2014). Telecentric stereo micro-vision system: Calibration method and experiments. Optics and Lasers in Engineering, 57, 82-92. doi:10.1016/j.optlaseng.2014.01.021

Stamatopoulos, C., & Fraser, C. S. (2011). Calibration of long focal length cameras in close range photogrammetry. The Photogrammetric Record, 26(135), 339-360. doi:10.1111/j.1477-9730.2011.00648.x [+]
Mitchell, H. L., Kniest, H. T., & Won‐Jin, O. (1999). Digital Photogrammetry and Microscope Photographs. The Photogrammetric Record, 16(94), 695-704. doi:10.1111/0031-868x.00148

Chen, Z., Liao, H., & Zhang, X. (2014). Telecentric stereo micro-vision system: Calibration method and experiments. Optics and Lasers in Engineering, 57, 82-92. doi:10.1016/j.optlaseng.2014.01.021

Stamatopoulos, C., & Fraser, C. S. (2011). Calibration of long focal length cameras in close range photogrammetry. The Photogrammetric Record, 26(135), 339-360. doi:10.1111/j.1477-9730.2011.00648.x

Yang, X., & Fang, S. (2014). Effect of field of view on the accuracy of camera calibration. Optik, 125(2), 844-849. doi:10.1016/j.ijleo.2013.07.089

Strobl, K. H., Sepp, W., & Hirzinger, G. (2009). On the issue of camera calibration with narrow angular field of view. 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems. doi:10.1109/iros.2009.5354776

Ricolfe-Viala, C., & Sanchez-Salmeron, A.-J. (2010). Lens distortion models evaluation. Applied Optics, 49(30), 5914. doi:10.1364/ao.49.005914

Ricolfe-Viala, C., Sanchez-Salmeron, A.-J., & Valera, A. (2013). Efficient Lens Distortion Correction for Decoupling in Calibration of Wide Angle Lens Cameras. IEEE Sensors Journal, 13(2), 854-863. doi:10.1109/jsen.2012.2229704

Zhang, Z. (2000). A flexible new technique for camera calibration. IEEE Transactions on Pattern Analysis and Machine Intelligence, 22(11), 1330-1334. doi:10.1109/34.888718

Percoco, G., Lavecchia, F., & Salmerón, A. J. S. (2015). Preliminary Study on the 3D Digitization of Millimeter Scale Products by Means of Photogrammetry. Procedia CIRP, 33, 257-262. doi:10.1016/j.procir.2015.06.046

Ricolfe-Viala, C., & Sanchez-Salmeron, A.-J. (2011). Camera calibration under optimal conditions. Optics Express, 19(11), 10769. doi:10.1364/oe.19.010769

Guidi, G. (2013). Metrological characterization of 3D imaging devices. Videometrics, Range Imaging, and Applications XII; and Automated Visual Inspection. doi:10.1117/12.2021037

Herráez, J., Martínez-Llario, J., Coll, E., Rodríguez, J., & Martin, M. T. (2013). Design and calibration of a 3D modeling system by videogrammetry. Measurement Science and Technology, 24(3), 035001. doi:10.1088/0957-0233/24/3/035001

[-]

recommendations

 

This item appears in the following Collection(s)

Show full item record