Gonzalez Diaz, D.; Álvarez Puerta, V.; Borges, FIG.; Camargo, M.; Carcel, S.; Cebrian, S.; Cervera, A.... (2015). Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 804:8-24. https://doi.org/10.1016/j.nima.2015.08.033
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/66178
Título:
|
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm
|
Autor:
|
Gonzalez Diaz, Diego
Álvarez Puerta, Vicente
Borges, F. I. G.
Camargo, M.
Carcel, S.
Cebrian, S.
Cervera, A.
Conde, C. A. N.
Dafni, T.
Esteve Bosch, Raul
Fernandes, L. M. P.
Mora Mas, Francisco José
Pérez Aparicio, José Luis
Rodríguez Samaniego, Javier
Toledo Alarcón, José Francisco
|
Entidad UPV:
|
Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures
Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
|
Fecha difusión:
|
|
Resumen:
|
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated ...[+]
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV).
This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussed
[-]
|
Palabras clave:
|
Double-beta decay
,
Gamma and electron detection
,
Microbulk micromegas
,
Time projection chambers
,
High pressure Xenon-Trimehylamine
,
Penning-Fluorescent mixtures
|
Derechos de uso:
|
Reserva de todos los derechos
|
Fuente:
|
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. (issn:
0168-9002
) (eissn:
1872-9576
)
|
DOI:
|
10.1016/j.nima.2015.08.033
|
Editorial:
|
Elsevier
|
Versión del editor:
|
http://dx.doi.org/10.1016/j.nima.2015.08.033
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/EC/FP7/339787/EU/Towards the NEXT generation of bb0nu experimets/
...[+]
info:eu-repo/grantAgreement/EC/FP7/339787/EU/Towards the NEXT generation of bb0nu experimets/
info:eu-repo/grantAgreement/MEC//CSD2007-00042/ES/Centro Nacional de Física de Partículas, Astropartículas y Nuclear/ /
info:eu-repo/grantAgreement/DOE//DE-AC02-05CH11231/
info:eu-repo/grantAgreement/FCT/5876-PPCDTI/103860/PT/Participation in the international collaboration "NEXT-Neutrino Experiment with a Xenon TPC" aiming the direct detection of the neutrinoless double beta decay/
info:eu-repo/grantAgreement/MICINN//FPA2008-03456/ES/PROGRAMA EXPERIMENTAL DE FISICA DE NEUTRINOS Y AXIONES DEL GRUPO DE LA UNIVERSIDAD DE ZARAGOZA. PARTICIPACION EN LOS EXPERIMENTOS SUPERNEMO EN EL LABORATORIO SUBTERRANEO DE CANFRANC Y CAST EN EL CERN/
info:eu-repo/grantAgreement/EC/FP7/240054/EU/Novel Developments in Time Projection Chambers (TPCs) for Rare Event Searches in Underground Astroparticle EXperiments/
info:eu-repo/grantAgreement/MICINN//CSD2008-00037/ES/Canfranc Underground Physics/
info:eu-repo/grantAgreement/MICINN//FPA2009-13697-C04/ES/Fisica Experimental De Neutrinos/
[-]
|
Agradecimientos:
|
The NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y ...[+]
The NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y Competitividad under grants Consolider-Ingenio 2010 CSD2008-0037 (CUP) and CSD2007-00042 (CPAN), contracts FPA2008-03456 and FPA2009-13697; Portuguese Fundacao para a Ciencia e a Tecnologia; European FEDER under grant PPTDC/FIS/103860/2008; US Department Of Energy under contract DE-AC02-05CH11231.
[-]
|
Tipo:
|
Artículo
|