Mostrar el registro sencillo del ítem
dc.contributor.author | Girón Hernández, Lunier Joel | es_ES |
dc.contributor.author | Gil Sánchez, Luís | es_ES |
dc.contributor.author | Garcia-Breijo, Eduardo | es_ES |
dc.contributor.author | Pagán Moreno, Mª Jesús | es_ES |
dc.contributor.author | Barat Baviera, José Manuel | es_ES |
dc.contributor.author | Grau Meló, Raúl | es_ES |
dc.date.accessioned | 2016-06-30T12:51:18Z | |
dc.date.available | 2016-06-30T12:51:18Z | |
dc.date.issued | 2015-08 | |
dc.identifier.issn | 0309-1740 | |
dc.identifier.uri | http://hdl.handle.net/10251/66828 | |
dc.description.abstract | Microbiological contamination in dry-cured ham can occur in the early stages of the process, a large number of microorganisms involved in spoilage can produce alterations in the product. These include non-common odours, which are detected at the end of the process by a procedure called cala , consisting of a sharp instrument punctured in every ham; this is smelled by an expert taster, who classifies hams as good and altered hams. An electronic device would be suitable for this process given the large amount of hams. The present research aims to develop objective equipment based on the potentiometry technique that identifies altered hams. A probe was developed, containing silver, nickel and copper electrodes, and was employed to classify altered and unaltered hams prior to classification by a tester. The results shown lower Ag and higher Cu potential values for altered hams. The differences in potentiometric response reveal a classification model, although further studies are required to obtain a reliable classification model. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Meat Science | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Potentiometry | es_ES |
dc.subject | Dry-cured ham | es_ES |
dc.subject | Principal component analysis | es_ES |
dc.subject | Microbiological ham quality | es_ES |
dc.subject.classification | TECNOLOGIA DE ALIMENTOS | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Development of potentiometric equipment for the identification of altered dry-cured hams: A preliminary study | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.meatsci.2015.03.006 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Tecnología de Alimentos - Departament de Tecnologia d'Aliments | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Girón Hernández, LJ.; Gil Sánchez, L.; Garcia-Breijo, E.; Pagán Moreno, MJ.; Barat Baviera, JM.; Grau Meló, R. (2015). Development of potentiometric equipment for the identification of altered dry-cured hams: A preliminary study. Meat Science. (106):1-5. doi:10.1016/j.meatsci.2015.03.006 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.meatsci.2015.03.006 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 5 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.issue | 106 | es_ES |
dc.relation.senia | 299284 | es_ES |