Correction algorithms for signal reduction in insensitive areas of a small gamma camera

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

Correction algorithms for signal reduction in insensitive areas of a small gamma camera

Show full item record

Seimetz, M.; Orero Palomares, A.; Morera Ballester, C.; Abellan Castillo, AI.; Polo Collado, R.; Hernández Hernández, L.; Vidal San Sebastián, LF.... (2014). Correction algorithms for signal reduction in insensitive areas of a small gamma camera. Journal of Instrumentation. 9(C05042):1-10. https://doi.org/10.1088/1748-0221/9/05/C05042

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/79437

Files in this item

Item Metadata

Title: Correction algorithms for signal reduction in insensitive areas of a small gamma camera
Author: Seimetz, Michael Orero Palomares, Abel Morera Ballester, Constantino Abellan Castillo, Adoracion Inmaculada Polo Collado, Ramiro Hernández Hernández, Liczandro Vidal San Sebastián, Luis Fernando Soriano Asensi, Antonio Pavón Hernández, Noriel Benlloch Baviera, Jose María
UPV Unit: Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes
Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Issued date:
Abstract:
The radiation sensitive part of the wide-field, small gamma camera Sentinella 108 consists of a monolithic, 102 x 102 mm2 wide CsI(Na) crystal coupled to four position-sensitive photomultipliers. These are read out via a ...[+]
Subjects: Gamma camera , Image reconstruction in medical imaging , Photon detectors for UV, visible and IR photons (vacuum)
Copyrigths: Cerrado
Source:
Journal of Instrumentation. (issn: 1748-0221 )
DOI: 10.1088/1748-0221/9/05/C05042
Publisher:
IOP Publishing
Publisher version: http://dx.doi.org/10.1088/1748-0221/9/05/C05042
Conference name: 15th International Workshop on Radiation Imaging Detector
Conference place: Paris, France
Conference date: 23-27 Jun. 2013
Project ID:
info:eu-repo/grantAgreement/MICINN//IDC-20101144/ES/NUEVAS TÉCNICAS DE CIRUGÍA GUIADA POR IMAGEN PARA EL CÁNCER DE COLON/
Thanks:
Project funded by the Centre for Industrial Technological Development (CDTI) through the Science Industry Subprogramme under Grant No. IDC-20101144.