Mostrar el registro sencillo del ítem
dc.contributor.author | Ye Lin, Yiyao![]() |
es_ES |
dc.contributor.author | Bueno Barrachina, José Manuel![]() |
es_ES |
dc.contributor.author | Prats-Boluda, Gema![]() |
es_ES |
dc.contributor.author | Rodríguez de Sanabria Gil, Rafael![]() |
es_ES |
dc.contributor.author | Garcia Casado, Francisco Javier![]() |
es_ES |
dc.date.accessioned | 2017-05-30T07:04:53Z | |
dc.date.available | 2017-05-30T07:04:53Z | |
dc.date.issued | 2017-02 | |
dc.identifier.issn | 0263-2241 | |
dc.identifier.uri | http://hdl.handle.net/10251/81977 | |
dc.description.abstract | [EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric dipole depth they can sense, but further experimental confirmation is needed. We aimed to develop and test a wireless multichannel ECG recording system based on a new flexible multi-ring electrode and to check the influence of CRE dimensions on the acquired signals. The system provided high-precision ECG signals by a simple procedure. The bipolar concentric ECG signal amplitude and SNR increase with the CRE¿s outer ring dimension. Differences in the signal morphologies, associated with different sensitivities to the location of the active dipoles, were also obtained in the case of diameters smaller than 34 mm. A system with several wireless sensor nodes developed could be easily used by clinical staff for non-invasive cardiac monitoring and diagnosis with high spatial and temporal resolution. | es_ES |
dc.description.sponsorship | Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); and by the Ministry of Economy and Competitiveness - Spain and the European Regional Development Fund (DPI2015-68397-R (MINECO/FEDER)). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Measurement | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Flexible multi-ring electrode | es_ES |
dc.subject | Wireless sensor node | es_ES |
dc.subject | Concentric ring electrode | es_ES |
dc.subject.classification | INGENIERIA ELECTRICA | es_ES |
dc.subject.classification | ORGANIZACION DE EMPRESAS | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.measurement.2016.11.009 | |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//GV%2F2014%2F029/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//SP20120490/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//DPI2015-68397-R/ES/ELECTROHISTEROGRAFIA, CONSTRUYENDO PUENTES PARA SU USO CLINICO EN OBSTETRICIA/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Facultad de Administración y Dirección de Empresas - Facultat d'Administració i Direcció d'Empreses | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Ye Lin, Y.; Bueno Barrachina, JM.; Prats-Boluda, G.; Rodríguez De Sanabria Gil, R.; Garcia Casado, FJ. (2017). Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode. Measurement. 97:195-202. https://doi.org/10.1016/j.measurement.2016.11.009 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/10.1016/j.measurement.2016.11.009 | es_ES |
dc.description.upvformatpinicio | 195 | es_ES |
dc.description.upvformatpfin | 202 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 97 | es_ES |
dc.relation.senia | 322028 | es_ES |
dc.identifier.eissn | 1873-412X | |
dc.contributor.funder | Generalitat Valenciana | |
dc.contributor.funder | Ministerio de Economía, Industria y Competitividad | |
dc.contributor.funder | Universitat Politècnica de València |