Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Ye Lin, Yiyao es_ES
dc.contributor.author Bueno Barrachina, José Manuel es_ES
dc.contributor.author Prats-Boluda, Gema es_ES
dc.contributor.author Rodríguez de Sanabria Gil, Rafael es_ES
dc.contributor.author Garcia Casado, Francisco Javier es_ES
dc.date.accessioned 2017-05-30T07:04:53Z
dc.date.available 2017-05-30T07:04:53Z
dc.date.issued 2017-02
dc.identifier.issn 0263-2241
dc.identifier.uri http://hdl.handle.net/10251/81977
dc.description.abstract [EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric dipole depth they can sense, but further experimental confirmation is needed. We aimed to develop and test a wireless multichannel ECG recording system based on a new flexible multi-ring electrode and to check the influence of CRE dimensions on the acquired signals. The system provided high-precision ECG signals by a simple procedure. The bipolar concentric ECG signal amplitude and SNR increase with the CRE¿s outer ring dimension. Differences in the signal morphologies, associated with different sensitivities to the location of the active dipoles, were also obtained in the case of diameters smaller than 34 mm. A system with several wireless sensor nodes developed could be easily used by clinical staff for non-invasive cardiac monitoring and diagnosis with high spatial and temporal resolution. es_ES
dc.description.sponsorship Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); and by the Ministry of Economy and Competitiveness - Spain and the European Regional Development Fund (DPI2015-68397-R (MINECO/FEDER)). en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Measurement es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Flexible multi-ring electrode es_ES
dc.subject Wireless sensor node es_ES
dc.subject Concentric ring electrode es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.subject.classification ORGANIZACION DE EMPRESAS es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.measurement.2016.11.009
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GV%2F2014%2F029/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//SP20120490/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//DPI2015-68397-R/ES/ELECTROHISTEROGRAFIA, CONSTRUYENDO PUENTES PARA SU USO CLINICO EN OBSTETRICIA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports es_ES
dc.contributor.affiliation Universitat Politècnica de València. Facultad de Administración y Dirección de Empresas - Facultat d'Administració i Direcció d'Empreses es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Ye Lin, Y.; Bueno Barrachina, JM.; Prats-Boluda, G.; Rodríguez De Sanabria Gil, R.; Garcia Casado, FJ. (2017). Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode. Measurement. 97:195-202. https://doi.org/10.1016/j.measurement.2016.11.009 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.1016/j.measurement.2016.11.009 es_ES
dc.description.upvformatpinicio 195 es_ES
dc.description.upvformatpfin 202 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 97 es_ES
dc.relation.senia 322028 es_ES
dc.identifier.eissn 1873-412X
dc.contributor.funder Generalitat Valenciana
dc.contributor.funder Ministerio de Economía, Industria y Competitividad
dc.contributor.funder Universitat Politècnica de València