Mostrar el registro completo del ítem
Dang, C.; Floyd, R.; Hale, WM.; Martí Vargas, JR. (2016). Measured Transfer Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams. Structural Journal. 113(1):85-94. doi:10.14359/51687941
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/85468
Título: | Measured Transfer Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams | |
Autor: | Dang, C.N. Floyd, R.W. Hale, W. M | |
Entidad UPV: |
|
|
Fecha difusión: |
|
|
Resumen: |
[EN] The use of 0.7 in. (17.8 mm), Grade 270 (1860) prestressing strands has advantages over 0.5 and 0.6 in. (12.7 and 15.22 mm) strands. This study provides design guidelines for estimating transfer length of 0.7 in. (17.8 ...[+]
|
|
Palabras clave: |
|
|
Derechos de uso: | Cerrado | |
Fuente: |
|
|
DOI: |
|
|
Editorial: |
|
|
Versión del editor: | http://dx.doi.org/10.14359/51687941 | |
Agradecimientos: |
The authors would like to acknowledge the financial and technical support from the Arkansas State Highway and Transportation Department (AHTD) and the Mack-Blackwell Rural Transportation Center (MBTC). The authors would ...[+]
|
|
Tipo: |
|