The mur neutralisant as an active thermal system: Saint Gobain tests (1931) versus CFD simulation (2015)

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

The mur neutralisant as an active thermal system: Saint Gobain tests (1931) versus CFD simulation (2015)

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Ramírez-Balas, C. es_ES
dc.contributor.author Sendra, J.J. es_ES
dc.contributor.author Suárez, R. es_ES
dc.contributor.author Fernández-Nieto, E.D. es_ES
dc.contributor.author Narbona-Reina, G. es_ES
dc.date.accessioned 2017-09-18T10:53:36Z
dc.date.available 2017-09-18T10:53:36Z
dc.date.issued 2016-03-03
dc.identifier.isbn 9788490483732
dc.identifier.uri http://hdl.handle.net/10251/87426
dc.description.abstract [EN] At the same time as the initial development of air conditioning systems for indoor climate control in buildings were occurring in USA, Le Corbusier and Lyon made truly innovative proposals for different projects he was working on in Europe. These served to generate homogenous thermal environments and focused on the combined effect of his mur neutralisant and respiration exacte. The clearest example of their shortcomings is the City of Refuge in Paris (1930-33). Given the technological and economic mistrust towards these proposals, as it was impossible to execute these according to the original plan these were not pursued. CFD simulations carried out by our research team confirm that the mur neutralisant and respiration exacte for the City of Refuge in Paris would have functioned together if they had been executed following the original plans. The main aim of this paper is to confirm the validity of the mur neutralisant as an active thermal system for buildings. Firstly, the results of the tests carried out by the engineers of Saint Gobain are compared to the results of the CFD simulations. Based on the comparison of the results from the physical models tested in Saint Gobain laboratories and CFD energy model simulations, a possible calibration is proposed for CFD which might prompt the establishment of other operation hypotheses. es_ES
dc.format.extent 23 es_ES
dc.language Inglés es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof LE CORBUSIER. 50 AÑOS DESPUÉS es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject architecture es_ES
dc.subject le corbusier es_ES
dc.subject modern movement es_ES
dc.title The mur neutralisant as an active thermal system: Saint Gobain tests (1931) versus CFD simulation (2015) es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/LC2015.2015.899
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Ramírez-Balas, C.; Sendra, J.; Suárez, R.; Fernández-Nieto, E.; Narbona-Reina, G. (2016). The mur neutralisant as an active thermal system: Saint Gobain tests (1931) versus CFD simulation (2015). En LE CORBUSIER. 50 AÑOS DESPUÉS. Editorial Universitat Politècnica de València. 1798-1819. https://doi.org/10.4995/LC2015.2015.899 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename LC2015 - Le Corbusier, 50 years later es_ES
dc.relation.conferencedate November 18-20,2015 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/LC2015/LC2015/paper/view/899 es_ES
dc.description.upvformatpinicio 1798 es_ES
dc.description.upvformatpfin 1819 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\899 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem