Studio e analisi della sicurezza in edificio storico. Caso pratico Certosa di Calci, Pisa

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Studio e analisi della sicurezza in edificio storico. Caso pratico Certosa di Calci, Pisa

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Palmero Iglesias, Luís Manuel es_ES
dc.contributor.author Palero García, José Alberto es_ES
dc.date.accessioned 2017-09-25T12:51:06Z
dc.date.available 2017-09-25T12:51:06Z
dc.date.created 2017-07-19
dc.date.issued 2017-09-25 es_ES
dc.identifier.uri http://hdl.handle.net/10251/87918
dc.description.abstract [IT] Gli edifici storici protetti spesso hanno grande difficoltà nell’applicazione delle norme di sicurezza vigenti. Non solo ci troviamo di fronte a edifici storici che non sono stati disposti per le esigenze attuali, ma anche per la sua natura storica e tutelata, hanno grandi difficoltà fronte ai cambiamenti. In questa tesi finale di laurea, analizzeremo la sicurezza della Galleria dei Cetacei, un padiglione del complesso monastico della Certosa di Calci, edificio storico tutelato. Questo analisi è stato effettuato sia con la normativa italiana che con la normativa spagnola, al fine di trovare analogie e differenze tra di loro, e anche per conoscere l’equilibrio di queste norme tra il rispetto per l’edificio storico e la protezione degli occupanti. Questo edificio ha due complicazioni che lo rendono molto interessante per lo studio della sicurezza. Da una parte, ha una geometria allungata di più di 100 metri di lunghezza per soli 7 metri di larghezza e le sue uniche uscite, sono ad un’estremità dell’edificio. D’altra parte, la sua coperta è formata da capriate in legno, un materiale combustibile che dobbiamo analizzare con attenzione per sapere se questa struttura resiste al fuoco il tempo necessario. es_ES
dc.description.abstract [EN] The historical protected buildings usually presents large difficulties at the time to apply the actual regulations in relation to security. We don’t only meet with an historical buildings which are not prepared to the actual requirements but also, for its historical and protected nature, they present big difficulties with changes. In this Final Grade Work we are going to analyze the security of “Galleria dei Cetacei”, a pavilion of the monastic complex of the “Certosa de Calci”, historical protected building, through the use of the the Italian and Spanish normative, with the aim to find similarities and differences between both of them, and also know the balance between the historical building respect and the protection of its occupants. This building shows two complications which makes it interesting for its study. On the one hand, it presents long geometry of more than 100 meters loungers and 7 meters wide and its unique exits are located at one end of the building. On the other hand the structure it's made by wooden truss, a combustible material that we should analyze with close attention to know if it resist the fire the enough time. es_ES
dc.format.extent 98 es_ES
dc.language Italiano es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Patrimonio architettonico es_ES
dc.subject Sicurezza antincendio es_ES
dc.subject Capriatas es_ES
dc.subject Strutture in legno es_ES
dc.subject Patrimonio arquitectónico es_ES
dc.subject Prevención de incendios es_ES
dc.subject Armaduras (Construcción) es_ES
dc.subject Estructuras de madera es_ES
dc.subject Ensayos de comportamiento ante el fuego es_ES
dc.subject Structural frames es_ES
dc.subject Fire prevention es_ES
dc.subject Building, Wooden es_ES
dc.subject Fire testing es_ES
dc.subject.classification CONSTRUCCIONES ARQUITECTONICAS es_ES
dc.subject.other Grado en Arquitectura Técnica-Grau en Arquitectura Tècnica es_ES
dc.title Studio e analisi della sicurezza in edificio storico. Caso pratico Certosa di Calci, Pisa es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Gestión en la Edificación - Escola Tècnica Superior de Gestió en l'Edificació es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Construcciones Arquitectónicas - Departament de Construccions Arquitectòniques es_ES
dc.description.bibliographicCitation Palero García, JA. (2017). Studio e analisi della sicurezza in edificio storico. Caso pratico Certosa di Calci, Pisa. http://hdl.handle.net/10251/87918. es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\51282 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)