- -

Propuesta de medidas pasivas para la mejora del funcionamiento bioclimático de la ETSAV

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Propuesta de medidas pasivas para la mejora del funcionamiento bioclimático de la ETSAV

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Carrión Mondéjar, Juan Carlos es_ES
dc.contributor.author Ruiz Morales, Rocío es_ES
dc.date.accessioned 2018-01-11T17:23:26Z
dc.date.available 2018-01-11T17:23:26Z
dc.date.created 2016-09-15
dc.date.issued 2018-01-11 es_ES
dc.identifier.uri http://hdl.handle.net/10251/94552
dc.description.abstract [ES] El presente trabajo tiene como objetivo el análisis del estado actual de una parte de la Escuela Técnica Superior de Arquitectura de Valencia, el edificio 2B y la propuesta de medidas para mejorar su funcionamiento energético. En un inicio, se explican y estudian los conceptos teóricos y estrategias para un diseño arquitectónico pasivo y bioclimático, una vez explicados se procede a analizar si el edificio 2B cumple dichos requisitos bioclimáticos y se propone una solución que garantice el confort higrotérmico de los usuarios en caso de no cumplirlos. En este trabajo se estudian el clima, el asoleamiento, los vientos, la orientación, la volumetría y la envolvente del edificio, para posteriormente calcular las transmitancias máximas de los elementos de la envolvente. En caso de no cumplir con la normativa establecida se calculan las transmitancias máximas, medias y condensaciones superficiales e intersticiales de la nueva propuesta para asegurar el cumplimiento del CTE. Tras esto, se estudia cómo mejorar la eficiencia energética de los huecos para evitar pérdidas de calor en invierno y ganancias en verano, se diseñan y calculan las protecciones necesarias en cada hueco según su orientación para reducir el consumo de energía y favorecer la ventilación natural. Tras el proceso descrito, se tienen los datos suficientes para mejorar el edificio y garantizar su eficiencia y comportamiento bioclimático con el que se conseguirá un ahorro de energía y en el que será posible alcanzar el confort requerido por los ocupantes. es_ES
dc.description.abstract [EN] The main goal of this thesis is to analyse the current conditions of a part of the Superior Technical School of Architecture of Valencia, 2B building and to propose measures to improve its bioclimatic functioning. On the first hand, the theoretical concepts and strategies are explained and studied to obtain a passive and bioclimatic architectural design, after that 2B building is analysed to know if it achieves the bioclimatic requirement, if it does not a solution which guarantee the hygrothermic comfort, of the users is proposed. In this thesis the weather, the sunlight, the wind, the orientation, the volume and the covering are studied to calculate the maximum transmittances of the covering elements. If they do not meet the regulation it is necessary to calculate the maximum and average transmittances and the condensations for a new proposal. After that, is studied how to improve the hole efficiency in order to prevent energy loss in winter and energy gain in summer. The shaft's protection are designed and calculated according to the orientation in order to reduce the energy consumption and improve natural ventilation. After all of that, enough data is gathered together to improve the building and guarantee its efficiency and bioclimatic behavior with which an energy-saving will be obtain and the comfort required will be reached. es_ES
dc.format.extent 76 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Bioclimatic functioning es_ES
dc.subject Passive architectural design es_ES
dc.subject Energy efficiency es_ES
dc.subject Energy-saving es_ES
dc.subject Hygrothermic comfort es_ES
dc.subject Funcionamiento bioclimático es_ES
dc.subject Diseño arquitectónico pasivo es_ES
dc.subject Eficiencia energética es_ES
dc.subject Ahorro de energía es_ES
dc.subject Confort higrotérmico es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Grado en Fundamentos de la Arquitectura-Grau en Fonaments de l'Arquitectura es_ES
dc.title Propuesta de medidas pasivas para la mejora del funcionamiento bioclimático de la ETSAV es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Ruíz Morales, R. (2016). Propuesta de medidas pasivas para la mejora del funcionamiento bioclimático de la ETSAV. http://hdl.handle.net/10251/94552 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\21589 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem