García Miquel, Ángel Héctor; Barrera Vilar, David; Amat, Rafael; Kurlyandskaya, G. V.; Sales Maicas, Salvador(Elsevier, 2016-02)
We have designed a temperature and strain monitoring system for a magnetic actuator
based on the giant magnetostrictive material Terfenol-D (Tb0.3 Dy0.7Fe1.92) with Fiber
Bragg grating (FBG) sensors. Magneto-elastic ...
[EN] There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional ...
Ionescu, A.; Vaz, C.A.F.; Trypiniotis, T.; Gürtler, C. M.; Vickers, M. E.; García Miquel, Ángel Héctor; Bland, J.A.C.(Elsevier, 2005)
[EN] In this study, we report experimental results on the structural and magnetic properties of epitaxial Fe3Si films grown on GaAs(0 0 1) by co-evaporation. X-ray reflectivity shows that relatively smooth interfaces are ...
[EN] Fe20Ni74Co6 and Fe20Ni64Co16 magnetic tubes electroplated onto Cu98Be2 conductive wire were investigated in the as-prepared state after heat treatment under a longitudinal DC magnetic field for 1 h at 300 degreesC or ...
Martorell-Tejedor, Sara; Tortajada-Genaro, Luis Antonio; Maquieira Catala, Angel(Elsevier, 2019-12-27)
[EN] The studied challenge is the specific detection of low-abundant genomic variants that differ by a single nucleotide from the wild type. The combination of blocked recombinase polymerase amplification (RPA) and selective ...
Mocholí Salcedo, Antonio; Arroyo-Núñez, José Humberto; Milian-Sanchez, Victor M.; Palomo-Anaya, M Jose; Arroyo-Nunez, Alexander(Institute of Electrical and Electronics Engineers, 2017-08)
[EN] In this paper, a detailed study about the value, in any point of space P(x, y, z), of the magnetic field generated by a rectangular loop that carries a current I has been made. The analysis focuses on the study of ...
In this paper, an optimization process, based on a genetic algorithm, is presented for the minimization of the cost (including losses) of ferromagnetic and conductive shields. The purpose of these shields is to maintain ...
Zamudio-Ramírez, Israel; Osornio-Rios, Roque Alfredo; Antonino-Daviu, J.; Razik, Hubert; Romero-Troncoso, Rene de Jesus(Institute of Electrical and Electronics Engineers, 2022-05)
[EN] Magnetic flux analysis is a condition monitoring technique that is drawing the interest of many researchers and motor manufacturers. The great enhancements and reduction in the costs and dimensions of the required ...
Cebrecos, Alejandro; Company, Miguel; Jimenez, Noe; Benlloch Baviera, Jose María; Camarena Femenia, Francisco(Acoustical Society of America, 2019-09-06)
[EN] A new method that combines transient magnetic forces with ultrasonic imaging and allows the local experimental characterization of the complex shear modulus of a viscoelastic medium is presented. By measuring the ...
Paz-Cedeno, Fernando Roberto; Carceller-Carceller, Jose Miguel; Iborra Chornet, Sara; Donato, Ricardo Keitel; Godoy, Anna Paula; de Paula, Ariela Veloso; Monti, Rubens; Corma Canós, Avelino; Masarin, Fernando(Elsevier, 2021-02)
[EN] For producing second-generation ethanol (cellulosic ethanol) and other value-added bioproducts, magnetic graphene oxide (GO-MNP) was synthesized in this work and used as the immobilization support for an industrial ...
Lorente Crespo, María; Wang, Li; Ortuño Molinero, Rubén; García Meca, Carlos; Ekinci, Yasin; Martínez Abietar, Alejandro José(American Chemical Society, 2013-06)
Ligh-matter interaction at optical frequencies is mostly mediated by the electric component of the
electromagnetic field, with the magnetic component usually being considered negligible. Recently, it has been shown that ...
Shi, Lei; Meseguer Rico, Francisco Javier(Optical Society of America, 2012-09-04)
[EN] The magnetic field component of light in dielectric materials generally plays a negligible role at optical frequency values. However, it is a key component of metal based metamaterials. Here we report on the dominant ...
[EN] The future air transport system will be confronted with new challenges: it must be safer,
greener and more effective than the current system (European, 2001, Flightpath, 2011,
Next, 2004, Strategic, ...
Manjavacas, Alejandro; Fenollosa Esteve, Roberto; Rodriguez, Isabelle; Jiménez Molero, María Consuelo; Miranda Alonso, Miguel Ángel; Meseguer Rico, Francisco Javier(The Royal Society of Chemistry, 2017)
[EN] Most optical processes occurring in nature are based on the well-known selection rules for opticaltransitions between electronic levels of atoms, molecules, and solids. Since in most situations themagnetic component ...
[EN] A selective magnetic molecularly imprinted polymer (MMIP) was synthetized with 4-chloro-2-methylphenoxyacetic acid as template and 4-vinylpiridine as monomer in presence of vinylized magnetite nanoparticles. Scanning ...
[EN] In this work, we have tested a photocatalytic material consisting of a core of SiO2/Fe3O4 coated with TiO2 (Magnox) for plausible tertiary wastewater treatment. For this, a pilot plant of 45 L equipped with an Ultraviolet ...
García Miquel, Ángel Héctor; Kurlyandskaya, G.V.; Levit, V.I.(Elsevier, 2006)
[EN] Low-frequency magnetic properties of ferromagnetic composite wires were studied with and without coating by ferrofluid. Nonmagnetic CuBe wires of 0.1 mm diameter were electroplated with FeCoNi layer of 1 mu m thickness. ...
[EN] Background Magnetic resonance imaging (MRI) is the most accurate imaging technique for left ventricular ejection fraction (LVEF) quantification, but as yet the prognostic value of LVEF assessment at any time after ...
Castillo-Malla, Darwin Patricio; Samaniego, R.; Jimenez, Y.; Cuenca, L.; Vivanco, O.; Rodríguez-Álvarez, M.J.(The International Society for Optical Engineering., 2018)
[EN] Brain demyelination lesions occur due to damage of the myelin layer of nerve fibers, this deterioration is the cause of pathologies such as multiple sclerosis, leukodystrophy, encephalomyelitis. Brain ischemia is the ...