Odour mapping and air quality analysis of a wastewater treatment plant at a seaside tourist area

dc.contributor.affiliationDepartamento de Ingeniería Hidráulica y Medio Ambiente
dc.contributor.affiliationInstituto Universitario de Ingeniería del Agua y del Medio Ambiente
dc.contributor.affiliationEscuela Técnica Superior de Ingeniería de Caminos, Canales y Puertos
dc.contributor.authorLuckert, Andreases_ES
dc.contributor.authorAguado García, Daniel
dc.contributor.authorGarcía-Bartual, Rafael
dc.contributor.authorLafita, Carloses_ES
dc.contributor.authorMontoya, Tatianaes_ES
dc.contributor.authorFrank, Norbertes_ES
dc.contributor.funderGeneralitat Valencianaes_ES
dc.date.accessioned2024-11-22T19:06:23Z
dc.date.available2024-11-22T19:06:23Z
dc.date.issued2023-08es_ES
dc.description.abstract[EN] Although wastewater treatment plants (WWTPs) play a fundamental role in protecting the aquatic environment as they prevent organic matter, nutrients and other pollutants from reaching the natural ecosystems, near residential areas they can generate unpleasant smells and noise. The plant studied in the present work is in a seaside tourist area in the Valencian Community, Spain. The main aim was to detect any possible perceptible H2S concentrations from the WWTP by experimental measurement campaigns (including sensor readings and olfactometry measurements by two experts) plus mathematical modelling. After a thorough data analysis of the essential variables involved, such as wind speed, wind direction and H2S concentrations (the main odorant) and comparing their temporal patterns, it was found that the probability of affecting the residential area was highest from June to August before noon and in the late evening. The hourly H2S concentration, influent flow rate and temperature showed a positive correlation, the strongest (R-2 = 0.89) being the relationship between the H2S concentration and influent flow rate. These two variables followed a similar daily pattern and indicated that H2S was emitted when influent wastewater was being pumped into the biological reactor. The H2S median concentration at the source of the emission was below 1393.865 & mu;g/m(3) (1 ppm), although concentrations 10 times higher were occasionally recorded. The observed H2S peak-to-mean ratio (1 min to 1 h of integration times) ranged from 1.15 to 16.03. This ratio and its attenuation with distance from the source depended on the atmospheric stability. Both H2S concentrations and variability were considerably reduced after submerging the inlet. The AERMOD modelling framework and applying the peak-to-mean ratio were used to map the peak H2S concentration and determine the best conditions to eliminate the unpleasant odour.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationLuckert, A.; Aguado García, D.; García-Bartual, R.; Lafita, C.; Montoya, T.; Frank, N. (2023). Odour mapping and air quality analysis of a wastewater treatment plant at a seaside tourist area. Environmental Monitoring and Assessment. 195(8). https://doi.org/10.1007/s10661-023-11598-8es_ES
dc.description.issue8es_ES
dc.description.sponsorshipThe EPSAR (Entidad Publica de Saneamiento de Aguas de la Comunitat Valenciana) is gratefully acknowledged for its support for this work.es_ES
dc.description.volume195es_ES
dc.identifier.doi10.1007/s10661-023-11598-8es_ES
dc.identifier.issn0167-6369es_ES
dc.identifier.pmid37526776es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/212163
dc.languageIngléses_ES
dc.publisherSpringer-Verlages_ES
dc.relation.ispartofEnvironmental Monitoring and Assessmentes_ES
dc.relation.pasarelaS\498533es_ES
dc.relation.publisherversionhttps://doi.org/10.1007/s10661-023-11598-8es_ES
dc.rightsReserva de todos los derechoses_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectAir qualityes_ES
dc.subjectDispersion modellinges_ES
dc.subjectHydrogen sulphidees_ES
dc.subjectOdour mapes_ES
dc.subjectWastewater treatmentes_ES
dc.subjectWWTPes_ES
dc.subject.classificationINGENIERIA HIDRAULICAes_ES
dc.subject.classificationTECNOLOGIA DEL MEDIO AMBIENTEes_ES
dc.subject.ods03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadeses_ES
dc.titleOdour mapping and air quality analysis of a wastewater treatment plant at a seaside tourist areaes_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
person.identifier40415
person.identifier3053
person.identifier.orcid0000-0002-6417-366X
person.identifier.orcid0000-0002-1811-8264
relation.isAuthorOfPublication4fd43aae-6009-4137-8a6d-5bb7437cd556
relation.isAuthorOfPublicationac0dfceb-65ae-424e-a20e-df8157497a39
relation.isAuthorOfPublication.latestForDiscovery4fd43aae-6009-4137-8a6d-5bb7437cd556
relation.isOrgUnitOfPublicatione8876040-9428-45e8-b805-b5bbc20e9e1e
relation.isOrgUnitOfPublication937991bf-5e71-4f67-ae2a-1fb780a35167
relation.isOrgUnitOfPublicationa4b47ff5-95f4-430f-a1a3-541cb8eaa9b7
relation.isOrgUnitOfPublication.latestForDiscoverye8876040-9428-45e8-b805-b5bbc20e9e1e
upv.uuidb73442e1-442b-4e6c-93a8-e741d50cb42ees_ES

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
LuckertAguadoGarcia-Bartual - Odour mapping and air quality analysis of a wastewater treatment pl....pdf
Tamaño:
1.37 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión del Autor.
Cargando...
Miniatura
Nombre:
Odour_mapping_EMAS.pdf
Tamaño:
1.92 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial