dc.description.abstract | [EN] This article presents a fault diagnosis strategy for open switch faults in the rotor side converter of doubly fed induction generators. The proposed strategy uses state observers based on dynamic models obtained from an approach based on differential geometry. These observers allow the generation of residue signals that are sensitive to each fault and insensitive to disturbances. From these signals a residual vector is constructed with information that can be used for the detection and isolation of the fault. The detection strategy consists of evaluating the envelope of the module of the residual vector. Isolation requires evaluating the region of the plane described by the residual vector and comparing that region with the one associated with each fault scenario. Finally, results are presented where it is demonstrated that the proposal allows to detect, isolate and identify open switch faults, both single and multiple, even against parametric errors and other disturbances. | es_ES |
dc.description.abstract | [ES] En este artículo se presenta una estrategia de diagnóstico de fallas por llave abierta en el convertidor del rotor de generadores de inducción con rotor bobinado. La estrategia utiliza observadores de estado basados en modelos dinámicos obtenidos a partir de un enfoque que utiliza geometría diferencial. Estos observadores permiten generar señales de residuo sensibles a cada falla considerada e insensibles a perturbaciones. A partir de estas señales se construye un vector de residuos con información que puede ser utilizada para la detección y el aislamiento de la falla. La estrategia de detección consiste en la evaluación de la envolvente de la norma del vector de residuos. El aislamiento requiere evaluar la región del plano recorrida por el vector de residuos y comparar dicha región con la asociada a cada escenario de falla. Finalmente se presentan resultados donde se demuestra que la propuesta permite detectar, aislar e identificar fallas de llave abierta, simples o múltiples, aún frente a errores paramétricos y otras perturbaciones. | es_ES |
dc.description.sponsorship | Este trabajo fue financiado por la Universidad Nacional de Río Cuarto, FONCyT-ANPCyT (Subsidio PICT-2014-3234) y CONICET (Subsidio PIP 2014-2016 GI 11220130100517CO). | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.relation.ispartof | Revista Iberoamericana de Automática e Informática industrial | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Doubly Fed Induction Generator | es_ES |
dc.subject | Rotor Side Converter | es_ES |
dc.subject | Open Switch Fault | es_ES |
dc.subject | Observers | es_ES |
dc.subject | Fault Scenario | es_ES |
dc.subject | Fault Diagnosis | es_ES |
dc.subject | Generador de inducción con rotor bobinado | es_ES |
dc.subject | Convertidor del rotor | es_ES |
dc.subject | Falla por llave abierta | es_ES |
dc.subject | Observadores | es_ES |
dc.subject | Escenarios de falla | es_ES |
dc.subject | Diagnóstico de fallas | es_ES |
dc.title | Diagnóstico de Fallas en el Convertidor del Rotor en Generadores de Inducción con Rotor Bobinado | es_ES |
dc.title.alternative | Detection and Isolation of Faults on the Rotor Side Converter of Doubly Fed Induction Generators | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.4995/riai.2017.9042 | |
dc.relation.projectID | info:eu-repo/grantAgreement/ANPCyT//PICT-2014-3234/AR/Diagnóstico de Averías en Accionamientos Eléctricos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/CONICET//IP 2014-2016 GI 11220130100517CO/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | González, GN.; De Angelo, CH.; Forchetti, DG.; Aligia, DA. (2018). Diagnóstico de Fallas en el Convertidor del Rotor en Generadores de Inducción con Rotor Bobinado. Revista Iberoamericana de Automática e Informática industrial. 15(3):297-308. https://doi.org/10.4995/riai.2017.9042 | es_ES |
dc.description.accrualMethod | OJS | es_ES |
dc.relation.publisherversion | https://doi.org/10.4995/riai.2017.9042 | es_ES |
dc.description.upvformatpinicio | 297 | es_ES |
dc.description.upvformatpfin | 308 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 15 | es_ES |
dc.description.issue | 3 | es_ES |
dc.identifier.eissn | 1697-7920 | |
dc.relation.pasarela | OJS\9042 | es_ES |
dc.contributor.funder | Universidad Nacional de Río Cuarto | es_ES |
dc.contributor.funder | Fondo para la Investigación Científica y Tecnológica, Argentina | es_ES |
dc.contributor.funder | Agencia Nacional de Promoción Científica y Tecnológica, Argentina | es_ES |
dc.contributor.funder | Consejo Nacional de Investigaciones Científicas y Técnicas, Argentina | es_ES |
dc.description.references | Aguilera, F., De la Barrera, P., De Angelo, C., Espinoza Trejo, D. R., 2013.Diagnóstico de fallas de sensor con enfoque geométrico para accionamientos con máquinas de inducción. In: XV Reunión de Trabajo en el Procesamiento de la Información y Control, RPIC2013. pp. 777-782. | es_ES |
dc.description.references | Campos-Delgado, D. U., Espinoza-Trejo, D. R., 2011. An observer-based diagnosis scheme for single and simultaneous open-switch faults in induction motor drives. IEEE Transactions on Industrial Electronics 58 (2), 671-679. https://doi.org/10.1109/TIE.2010.2047829 | es_ES |
dc.description.references | Campos-Delgado, D. U., Pecina-Sanchez, J. A., Espinoza-Trejo, D. R., Arce-Santana, E. R., 2013. Diagnosis of open-switch faults in variable speed drives by stator current analysis and pattern recognition. IET Electric Power Applications 7 (6), 509-522. https://doi.org/10.1049/iet-epa.2013.0015 | es_ES |
dc.description.references | De Araujo Ribeiro, R. L., Jacobina, C. B., Cabral da Silva, E. R., Lima, A.M. N., 2003. Fault detection of open-switch damage in voltage-fed pwm motor drive systems. IEEE Transactions on Power Electronics 18 (2), 587-593. https://doi.org/10.1109/TPEL.2003.809351 | es_ES |
dc.description.references | De Persis, C., Isidori, A., 2001. A geometric approach to nonlinear fault detection and isolation. IEEE Transactions on Automatic Control 46 (6), 853-865. https://doi.org/10.1109/9.928586 | es_ES |
dc.description.references | Espinoza-Trejo, D. R., Loredo-Flores, A., Montoya-Villanueva, S., Compeán-Martínez, I., De Angelo, C. H., Bossio, G. R., Campos-Delgado, D. U.,2011. Detección y aislamiento de conjuntos de fallas de estator para el mi trifásico: Un enfoque geométrico. XVIII Congreso Internacional de Ingeniería Eléctrica, Electrónica, De Sistemas y Ramas Afines, IEEE INTER-CON 2011. | es_ES |
dc.description.references | Feng, Y., Zhou, J., Qiu, Y., Feng, K., 2013. Fault tolerance for wind turbine power converter. In: 2nd IET Renewable Power Generation Conference (RPG2013). pp. 1-4. https://doi.org/10.1049/cp.2013.1831 | es_ES |
dc.description.references | González, G., Forchetti, D., Aguilera, F., De Angelo, C., 2016. Diagnóstico de fallas en el convertidor del rotor en sistemas de generación basados en girb. In: 2016 IEEE Biennial Congress of Argentina (ARGENCON). https://doi.org/10.1109/ARGENCON.2016.7585250 | es_ES |
dc.description.references | IEEE, 2004. Standard. 112 - IEEE stadard procedure for polyphase induction motors and generators. Tech. rep., IEEE Power Engineering Society. | es_ES |
dc.description.references | Isermann, R., 2011. Fault-Diagnosis Applications,"Model-based condition monitoring: Atuators, drives, machinery, plants, sensors, and fault-tolerants systems". Springer. https://doi.org/10.1007/978-3-642-12767-0 | es_ES |
dc.description.references | Khalil, H. K., 1996. Noninear Systems. Prentice-Hall, New Jersey. | es_ES |
dc.description.references | Krause, P., Wasynczuk, O., Sudho, S., 2013. Analysis of electric machinery. IEEE PRESS. | es_ES |
dc.description.references | Lie, X., Yi, W., 2007. Dynamic modeling and control of dfig-based wind turbines under unbalanced network conditions. IEEE Transactions on PowerSystems 22 (1), 314-323. https://doi.org/10.1109/TPWRS.2006.889113 | es_ES |
dc.description.references | Lu, B., Sharma, S. K., 2009. A literature review of igbt fault diagnostic and protection methods for power inverters. IEEE Transactions on Industry Applications 45 (5), 1770-1777. https://doi.org/10.1109/TIA.2009.2027535 | es_ES |
dc.description.references | Masrur, M. A., Zhihang, C., Zhang, B., Murphey, Y. L., 2007. Model-based fault diagnosis in electric drive inverters using artificial neural network. In: 2007 IEEE Power Engineering Society General Meeting. pp. 1-7. https://doi.org/10.1109/PES.2007.385655 | es_ES |
dc.description.references | Muller, S., Deicke, M., De Doncker, R. W., 2002. Doubly fed induction genera-tor systems for wind turbines. IEEE Industry Applications Magazine 8 (3), 26-33. https://doi.org/10.1109/2943.999610 | es_ES |
dc.description.references | Pan, D., Kai-gui, X., Li, Z., Xianliang, R., 2011. Open-switch fault diagnosis and system reconfiguration of doubly fed wind power converter used in a microgrid. Power Electronics, IEEE Transactions on 26 (3), 816-821. | es_ES |
dc.description.references | Protsenko, K., Dewei, X., 2007. Modeling and control of brushless doubly-fed induction generators in wind energy applications. In: Twenty Second Annual IEEE Applied Power Electronics Conference, APEC 2007. pp. 529-535. https://doi.org/10.1109/APEX.2007.357565 | es_ES |
dc.description.references | Sae-Kok, W., Grant, D. M., 2007. Open switch fault diagnosis for a doubly-fed induction generator. In: 7th International Conference on Power Electronics and Drive Systems, 2007. PEDS '07. pp. 131-138. https://doi.org/10.1109/PEDS.2007.4487691 | es_ES |
dc.description.references | Shahbazi, M., Saadate, S., Poure, P., Zolghadri, M., 2016. Open-circuit switch fault tolerant wind energy conversion system based on six/five-leg reconfigurable converter. Electric Power Systems Research 137, 104 - 112. https://doi.org/10.1016/j.epsr.2016.04.004 | es_ES |