Mostrar el registro sencillo del ítem
dc.contributor.author | Bravo M., Diego A. | es_ES |
dc.contributor.author | Rengifo R., Carlos F. | es_ES |
dc.date.accessioned | 2020-05-22T18:31:44Z | |
dc.date.available | 2020-05-22T18:31:44Z | |
dc.date.issued | 2014-10-05 | |
dc.identifier.issn | 1697-7912 | |
dc.identifier.uri | http://hdl.handle.net/10251/144169 | |
dc.description.abstract | [EN] This paper presents the biomechanical model of a prosthetic leg. In order to study the change of speed in the joint prosthesisstump upon impact of the foot with the ground is modeled as a spring-damper system, allowing demonstrate the need to build the stump-prosthesis junction impedance devices mechanical variable. This platform is also proposed with the aim of simulating virtual representations to a patient with prosthesis, as a stage prior to the actual implementation thereof. | es_ES |
dc.description.abstract | [ES] En este trabajo se presenta el modelo biomecánico de una prótesis de pierna. Con el objetivo de estudiar el cambio de velocidad en la unión prótesis-muñón al momento del impacto del pie con el suelo, está se modeló como un sistema resorte-amortiguador, per- mitiendo evidenciar la necesidad de construir la unión muñón-prótesis con dispositivos de impedancia mecánica variable. Adema's se desarrolló un simulador con el objetivo de hacer representaciones virtuales de un paciente con prótesis. Para ello se modeló al paciente como un robot b́ıpedo planar, el simulador permite estudiar el efecto de las fuerzas de impacto con el suelo de la unión prótesis-muñón como una etapa anterior a la implementación real de la misma. | es_ES |
dc.description.sponsorship | Los autores expresan sus mas sinceros agradecimientos a la Universidad del Cauca en Colombia por todo el apoyo académico y financiero brindado en este proyecto. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Revista Iberoamericana de Automática e Informática industrial | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Human gait | es_ES |
dc.subject | Biomechanical model | es_ES |
dc.subject | Prosthesis | es_ES |
dc.subject | Simulation | es_ES |
dc.subject | Marcha humana | es_ES |
dc.subject | Modelo biomecánico | es_ES |
dc.subject | Prótesis | es_ES |
dc.subject | Simulación | es_ES |
dc.title | Modelo Biomecánico de una Prótesis de Pierna | es_ES |
dc.title.alternative | Biomechanical Model of a Prosthetic Leg | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.riai.2014.08.003 | |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Bravo M., DA.; Rengifo R., CF. (2014). Modelo Biomecánico de una Prótesis de Pierna. Revista Iberoamericana de Automática e Informática industrial. 11(4):417-425. https://doi.org/10.1016/j.riai.2014.08.003 | es_ES |
dc.description.accrualMethod | OJS | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.riai.2014.08.003 | es_ES |
dc.description.upvformatpinicio | 417 | es_ES |
dc.description.upvformatpfin | 425 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 11 | es_ES |
dc.description.issue | 4 | es_ES |
dc.identifier.eissn | 1697-7920 | |
dc.relation.pasarela | OJS\9433 | es_ES |
dc.contributor.funder | Universidad del Cauca | es_ES |
dc.description.references | Anitescu, M., & Potra, F. A. (1997). Nonlinear Dynamics, 14(3), 231-247. doi:10.1023/a:1008292328909 | es_ES |
dc.description.references | Colombo, G., Filippi, S., Rizzi, C., & Rotini, F. (2010). A new design paradigm for the development of custom-fit soft sockets for lower limb prostheses. Computers in Industry, 61(6), 513-523. doi:10.1016/j.compind.2010.03.008 | es_ES |
dc.description.references | Dellon, B., & Matsuoka, Y. (2007). Prosthetics, exoskeletons, and rehabilitation [Grand Challenges of Robotics]. IEEE Robotics & Automation Magazine, 14(1), 30-34. doi:10.1109/mra.2007.339622 | es_ES |
dc.description.references | Ferris, A. E., Aldridge, J. M., Rábago, C. A., & Wilken, J. M. (2012). Evaluation of a Powered Ankle-Foot Prosthetic System During Walking. Archives of Physical Medicine and Rehabilitation, 93(11), 1911-1918. doi:10.1016/j.apmr.2012.06.009 | es_ES |
dc.description.references | Hobara, H., Baum, B. S., Kwon, H.-J., Miller, R. H., Ogata, T., Kim, Y. H., & Shim, J. K. (2013). Amputee locomotion: Spring-like leg behavior and stiffness regulation using running-specific prostheses. Journal of Biomechanics, 46(14), 2483-2489. doi:10.1016/j.jbiomech.2013.07.009 | es_ES |
dc.description.references | Jiménez-Fabián, R., & Verlinden, O. (2012). Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. Medical Engineering & Physics, 34(4), 397-408. doi:10.1016/j.medengphy.2011.11.018 | es_ES |
dc.description.references | Lee, J. H., Yi, B.-J., & Lee, J. Y. (2012). Adjustable spring mechanisms inspired by human musculoskeletal structure. Mechanism and Machine Theory, 54, 76-98. doi:10.1016/j.mechmachtheory.2012.03.012 | es_ES |
dc.description.references | Martins, M. M., Santos, C. P., Frizera-Neto, A., & Ceres, R. (2012). Assistive mobility devices focusing on Smart Walkers: Classification and review. Robotics and Autonomous Systems, 60(4), 548-562. doi:10.1016/j.robot.2011.11.015 | es_ES |
dc.description.references | Nandi, G. C., Ijspeert, A. J., Chakraborty, P., & Nandi, A. (2009). Development of Adaptive Modular Active Leg (AMAL) using bipedal robotics technology. Robotics and Autonomous Systems, 57(6-7), 603-616. doi:10.1016/j.robot.2009.02.002 | es_ES |
dc.description.references | Wentink, E. C., Koopman, H. F. J. M., Stramigioli, S., Rietman, J. S., & Veltink, P. H. (2013). Variable stiffness actuated prosthetic knee to restore knee buckling during stance: A modeling study. Medical Engineering & Physics, 35(6), 838-845. doi:10.1016/j.medengphy.2012.08.016 | es_ES |
dc.description.references | Whittlesey, S. N., van Emmerik, R. E. A., & Hamill, J. (2000). The Swing Phase of Human Walking Is Not a Passive Movement. Motor Control, 4(3), 273-292. doi:10.1123/mcj.4.3.273 | es_ES |
dc.description.references | Xie, H.-L., Liang, Z.-Z., Li, F., & Guo, L.-X. (2010). The knee joint design and control of above-knee intelligent bionic leg based on magneto-rheological damper. International Journal of Automation and Computing, 7(3), 277-282. doi:10.1007/s11633-010-0503-y | es_ES |