- -

A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging

Mostrar el registro completo del ítem

Martins, PM.; Dal Bello, R.; Seimetz, M.; Hermann, G.; Kihm, T.; Seco, J. (2020). A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging. Frontiers in Physics. 8:1-13. https://doi.org/10.3389/fphy.2020.00169

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/161214

Ficheros en el ítem

Metadatos del ítem

Título: A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging
Autor: Martins, Paulo Magalhaes Dal Bello, Riccardo Seimetz, Michael Hermann, German Kihm, Thomas Seco, Joao
Entidad UPV: Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Fecha difusión:
Resumen:
[EN] Tracking of single particles accelerated by synchrotrons is a subject that crosses several physics fields. The high clinical intensities used in particle therapy that can exceed 10(9)p/s make this task very challenging. ...[+]
Palabras clave: Prompt-gamma , Particle tracking scintillating fibers , Ion-beam therapy , Synchrotons
Derechos de uso: Reconocimiento (by)
Fuente:
Frontiers in Physics. (eissn: 2296-424X )
DOI: 10.3389/fphy.2020.00169
Editorial:
Frontiers Media
Versión del editor: https://doi.org/10.3389/fphy.2020.00169
Agradecimientos:
PM was supported by a research fellowship for postdoctoral researchers from the Alexander von Humboldt Foundation, Bonn, Germany. RD was supported by the International Max Planck Research School for Quantum Dynamics in ...[+]
Tipo: Artículo

References

Parodi, K., Crespo, P., Eickhoff, H., Haberer, T., Pawelke, J., Schardt, D., & Enghardt, W. (2005). Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 545(1-2), 446-458. doi:10.1016/j.nima.2005.02.002

Crespo, P., Barthel, T., Frais-Kolbl, H., Griesmayer, E., Heidel, K., Parodi, K., … Enghardt, W. (2005). Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities. IEEE Transactions on Nuclear Science, 52(4), 980-987. doi:10.1109/tns.2005.852637

Testa, E., Bajard, M., Chevallier, M., Dauvergne, D., Le Foulher, F., Freud, N., … Testa, M. (2008). Monitoring the Bragg peak location of 73MeV∕u carbon ions by means of prompt γ-ray measurements. Applied Physics Letters, 93(9), 093506. doi:10.1063/1.2975841 [+]
Parodi, K., Crespo, P., Eickhoff, H., Haberer, T., Pawelke, J., Schardt, D., & Enghardt, W. (2005). Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 545(1-2), 446-458. doi:10.1016/j.nima.2005.02.002

Crespo, P., Barthel, T., Frais-Kolbl, H., Griesmayer, E., Heidel, K., Parodi, K., … Enghardt, W. (2005). Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities. IEEE Transactions on Nuclear Science, 52(4), 980-987. doi:10.1109/tns.2005.852637

Testa, E., Bajard, M., Chevallier, M., Dauvergne, D., Le Foulher, F., Freud, N., … Testa, M. (2008). Monitoring the Bragg peak location of 73MeV∕u carbon ions by means of prompt γ-ray measurements. Applied Physics Letters, 93(9), 093506. doi:10.1063/1.2975841

Biegun, A. K., Seravalli, E., Lopes, P. C., Rinaldi, I., Pinto, M., Oxley, D. C., … Schaart, D. R. (2012). Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study. Physics in Medicine and Biology, 57(20), 6429-6444. doi:10.1088/0031-9155/57/20/6429

Smeets, J., Roellinghoff, F., Prieels, D., Stichelbaut, F., Benilov, A., Busca, P., … Dubus, A. (2012). Prompt gamma imaging with a slit camera for real-time range control in proton therapy. Physics in Medicine and Biology, 57(11), 3371-3405. doi:10.1088/0031-9155/57/11/3371

Verburg, J. M., Riley, K., Bortfeld, T., & Seco, J. (2013). Energy- and time-resolved detection of prompt gamma-rays for proton range verification. Physics in Medicine and Biology, 58(20), L37-L49. doi:10.1088/0031-9155/58/20/l37

Golnik, C., Hueso-González, F., Müller, A., Dendooven, P., Enghardt, W., Fiedler, F., … Pausch, G. (2014). Range assessment in particle therapy based on promptγ-ray timing measurements. Physics in Medicine and Biology, 59(18), 5399-5422. doi:10.1088/0031-9155/59/18/5399

Cambraia Lopes, P., Clementel, E., Crespo, P., Henrotin, S., Huizenga, J., Janssens, G., … Schaart, D. R. (2015). Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters. Physics in Medicine and Biology, 60(15), 6063-6085. doi:10.1088/0031-9155/60/15/6063

Petzoldt, J., Roemer, K. E., Enghardt, W., Fiedler, F., Golnik, C., Hueso-González, F., … Pausch, G. (2016). Characterization of the microbunch time structure of proton pencil beams at a clinical treatment facility. Physics in Medicine and Biology, 61(6), 2432-2456. doi:10.1088/0031-9155/61/6/2432

Verburg, J. M., & Seco, J. (2014). Proton range verification through prompt gamma-ray spectroscopy. Physics in Medicine and Biology, 59(23), 7089-7106. doi:10.1088/0031-9155/59/23/7089

Hueso-González, F., Enghardt, W., Fiedler, F., Golnik, C., Janssens, G., Petzoldt, J., … Pausch, G. (2015). First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility. Physics in Medicine and Biology, 60(16), 6247-6272. doi:10.1088/0031-9155/60/16/6247

Martins, P. M., Dal Bello, R., Rinscheid, A., Roemer, K., Werner, T., Enghardt, W., … Seco, J. (2017). Prompt gamma spectroscopy for range control with CeBr3. Current Directions in Biomedical Engineering, 3(2), 113-117. doi:10.1515/cdbme-2017-0023

Gil, E. C., Albarrán, E. M., Minucci, E., Nüssle, G., Padolski, S., Petrov, P., … Kozhuharov, V. (2017). The beam and detector of the NA62 experiment at CERN. Journal of Instrumentation, 12(05), P05025-P05025. doi:10.1088/1748-0221/12/05/p05025

Schüttauf, A. (2004). Timing RPCs in FOPI. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 533(1-2), 65-68. doi:10.1016/j.nima.2004.07.002

Alici, A. (2012). Status and performance of the ALICE MRPC-based Time-Of-Flight detector. Journal of Instrumentation, 7(10), P10024-P10024. doi:10.1088/1748-0221/7/10/p10024

Blanco, A., Fonte, P., Garzon, J. A., Koenig, W., Kornakov, G., & Lopes, L. (2013). Performance of the HADES-TOF RPC wall in a Au + Au beam at 1.25 AGeV. Journal of Instrumentation, 8(01), P01004-P01004. doi:10.1088/1748-0221/8/01/p01004

Sadrozinski, H. F.-W., Ely, S., Fadeyev, V., Galloway, Z., Ngo, J., Parker, C., … Vinattieri, A. (2013). Ultra-fast silicon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 730, 226-231. doi:10.1016/j.nima.2013.06.033

Cartiglia, N., Staiano, A., Sola, V., Arcidiacono, R., Cirio, R., Cenna, F., … Zavrtanik, M. (2017). Beam test results of a 16 ps timing system based on ultra-fast silicon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 850, 83-88. doi:10.1016/j.nima.2017.01.021

Sadrozinski, H. F.-W., Seiden, A., & Cartiglia, N. (2017). 4D tracking with ultra-fast silicon detectors. Reports on Progress in Physics, 81(2), 026101. doi:10.1088/1361-6633/aa94d3

Beddar, A. S., Mackie, T. R., & Attix, F. H. (1992). Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations. Physics in Medicine and Biology, 37(10), 1883-1900. doi:10.1088/0031-9155/37/10/006

Beddar, A. S., Mackie, T. R., & Attix, F. H. (1992). Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. Physics in Medicine and Biology, 37(10), 1901-1913. doi:10.1088/0031-9155/37/10/007

Beaulieu, L., & Beddar, S. (2016). Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy. Physics in Medicine and Biology, 61(20), R305-R343. doi:10.1088/0031-9155/61/20/r305

Beddar, S., & Beaulieu, L. (Eds.). (2016). Scintillation Dosimetry. Imaging in Medical Diagnosis and Therapy. doi:10.1201/b19491

Marcatili, S., Collot, J., Curtoni, S., Dauvergne, D., Hostachy, J.-Y., Koumeir, C., … Yamouni, M. (2020). Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy. Physics in Medicine & Biology, 65(24), 245033. doi:10.1088/1361-6560/ab7a6c

Kirn, T. (2017). SciFi – A large scintillating fibre tracker for LHCb. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 845, 481-485. doi:10.1016/j.nima.2016.06.057

Leverington, B. D., Dziewiecki, M., Renner, L., & Runze, R. (2018). A prototype scintillating fibre beam profile monitor for Ion Therapy beams. Journal of Instrumentation, 13(05), P05030-P05030. doi:10.1088/1748-0221/13/05/p05030

Vignati, A., Monaco, V., Attili, A., Cartiglia, N., Donetti, M., Mazinani, M. F., … Cirio, R. (2017). Innovative thin silicon detectors for monitoring of therapeutic proton beams: preliminary beam tests. Journal of Instrumentation, 12(12), C12056-C12056. doi:10.1088/1748-0221/12/12/c12056

Krimmer, J., Dauvergne, D., Létang, J. M., & Testa, É. (2018). Prompt-gamma monitoring in hadrontherapy: A review. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 878, 58-73. doi:10.1016/j.nima.2017.07.063

Pausch, G., Berthold, J., Enghardt, W., Römer, K., Straessner, A., Wagner, A., … Kögler, T. (2020). Detection systems for range monitoring in proton therapy: Needs and challenges. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 954, 161227. doi:10.1016/j.nima.2018.09.062

Hueso-Gonzalez, F., & Bortfeld, T. (2020). Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: A Theoretical Study. IEEE Transactions on Radiation and Plasma Medical Sciences, 4(2), 170-183. doi:10.1109/trpms.2019.2930362

Haberer, T., Debus, J., Eickhoff, H., Jäkel, O., Schulz-Ertner, D., & Weber, U. (2004). The heidelberg ion therapy center. Radiotherapy and Oncology, 73, S186-S190. doi:10.1016/s0167-8140(04)80046-x

Hara, K., Hata, K., Kim, S., Mishina, M., Sano, M., Seiya, Y., … Yasuoka, K. (1998). Radiation hardness and mechanical durability of Kuraray optical fibers. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 411(1), 31-40. doi:10.1016/s0168-9002(98)00281-2

Joram, C., Haefeli, G., & Leverington, B. (2015). Scintillating Fibre Tracking at High Luminosity Colliders. Journal of Instrumentation, 10(08), C08005-C08005. doi:10.1088/1748-0221/10/08/c08005

EkelhofRJ Studies for the LHCb SciFi Tracker - Development of Modules from Scintillating Fibres and Tests of their Radiation Hardness2016

Online control of particle therapy - CLaRyS collaboration1825 DauvergneD Final MediNet Network Meeting2019

Tessonnier, T., Mairani, A., Chen, W., Sala, P., Cerutti, F., Ferrari, A., … Parodi, K. (2018). Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison. Radiation Oncology, 13(1). doi:10.1186/s13014-017-0944-3

Mein, S., Dokic, I., Klein, C., Tessonnier, T., Böhlen, T. T., Magro, G., … Mairani, A. (2019). Biophysical modeling and experimental validation of relative biological effectiveness (RBE) for 4He ion beam therapy. Radiation Oncology, 14(1). doi:10.1186/s13014-019-1295-z

Schoemers, C., Feldmeier, E., Naumann, J., Panse, R., Peters, A., & Haberer, T. (2015). The intensity feedback system at Heidelberg Ion-Beam Therapy Centre. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 795, 92-99. doi:10.1016/j.nima.2015.05.054

Werner, F., Bauer, C., Bernhard, S., Capasso, M., Diebold, S., Eisenkolb, F., … Zietara, K. (2017). Performance verification of the FlashCam prototype camera for the Cherenkov Telescope Array. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 876, 31-34. doi:10.1016/j.nima.2016.12.056

Actis, M., Agnetta, G., Aharonian, F., Akhperjanian, A., Aleksić, J., … Antico, F. (2011). Design concepts for the Cherenkov Telescope Array CTA: an advanced facility for ground-based high-energy gamma-ray astronomy. Experimental Astronomy, 32(3), 193-316. doi:10.1007/s10686-011-9247-0

Dal Bello, R., Magalhaes Martins, P., Graça, J., Hermann, G., Kihm, T., & Seco, J. (2019). Results from the experimental evaluation of CeBr scintillators for He prompt gamma spectroscopy. Medical Physics, 46(8), 3615-3626. doi:10.1002/mp.13594

Puehlhofer, G., Bauer, C., Bernhard, S., Capasso, M., Diebold, S., Eisenkolb, F., … Zietara, K. (2016). FlashCam: a fully-digital camera for the medium-sized telescopes of the Cherenkov Telescope Array. Proceedings of The 34th International Cosmic Ray Conference — PoS(ICRC2015). doi:10.22323/1.236.1039

Testa, M., Bajard, M., Chevallier, M., Dauvergne, D., Freud, N., Henriquet, P., … Testa, E. (2010). Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection. Radiation and Environmental Biophysics, 49(3), 337-343. doi:10.1007/s00411-010-0276-2

Dal Bello, R., Magalhaes Martins, P., Brons, S., Hermann, G., Kihm, T., Seimetz, M., & Seco, J. (2020). Prompt gamma spectroscopy for absolute range verification of 12C ions at synchrotron-based facilities. Physics in Medicine & Biology, 65(9), 095010. doi:10.1088/1361-6560/ab7973

21768 LeoWR Techniques for Nuclear and Particle Physics Experiments: A How-to Approach1994

Graeff, C., Weber, U., Schuy, C., Saito, N., Volz, L., Piersimoni, P., … Kraemer, M. (2018). [OA027] Helium as a range probe in carbon ion therapy. Physica Medica, 52, 11. doi:10.1016/j.ejmp.2018.06.099

Mazzucconi, D., Agosteo, S., Ferrarini, M., Fontana, L., Lante, V., Pullia, M., & Savazzi, S. (2018). Mixed particle beam for simultaneous treatment and online range verification in carbon ion therapy: Proof‐of‐concept study. Medical Physics, 45(11), 5234-5243. doi:10.1002/mp.13219

Scintillating Fiber Trackers: recent developments and applications204 BlancF 14th ICATPP Conference on Astroparticle, Particle, Space Physics and Detectors for Physics Applications2013

JoramC UwerU LeveringtonBD KirnT BachmannS EkelhofRJ LHCb Scintillating Fibre Tracker Engineering Design Review Report: Fibres, Mats and Modules2015

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem