Mostrar el registro sencillo del ítem
dc.contributor.author | Ochoa Sosa, Jonathan Emmanuel | es_ES |
dc.contributor.author | Núñez, Rubén | es_ES |
dc.contributor.author | Oggier, Germán Elías | es_ES |
dc.contributor.author | Oggier, Germán Gustavo | es_ES |
dc.contributor.author | García, Guillermo | es_ES |
dc.date.accessioned | 2022-05-24T08:07:36Z | |
dc.date.available | 2022-05-24T08:07:36Z | |
dc.date.issued | 2022-04-01 | |
dc.identifier.issn | 1697-7912 | |
dc.identifier.uri | http://hdl.handle.net/10251/182824 | |
dc.description.abstract | [EN] This work proposes a fault-tolerant new mode operation applied to three-phase dual active bridge dc-dc converters (CPDA3) when a transistor open-circuit fault occurs on the load-side bridge. The proposal is to modify the signals of transistor activation, in order to keep the power transfer within certain limits after reconfiguration. This approach does not introduce additional computational costs and does not require the incorporation of additional components or circuits to the original topology. The maximum power that can be transferred is larger compared to previous proposals. In addition, the output voltage ripple is significantly reduced, which allows the expected lifetime of the filter capacitors to be increased. Simulation and experimental results of a 1.5 kW prototype are presented to validate the theoretical analysis and the feasibility of the proposal. | es_ES |
dc.description.abstract | [ES] Este trabajo propone un nuevo funcionamiento en modo tolerante a fallas aplicado a convertidores CC-CC con Puentes Duales Activos Trifasicos (CPDA3) cuando ocurre una falla de circuito abierto de transistor en el puente del lado de la carga. La propuesta consiste en modificar las senales de activación de los transistores, para lograr mantener la transferencia de potencia dentro de determinados limites despues de la reconfiguración. Este enfoque no introduce costos computacionales adicionales y no requiere la incorporacion de componentes o circuitos adicionales a la topología original. La potencia maxima que se puede transferir es mayor comparado conlas propuestas anteriores. Ademas, la ondulación de la tensión de salida se reduce significativamente, lo que permite aumentar la vida util esperada de los capacitores del filtro. Se presentan los resultados de la simulación y experimentales de un prototipo de 1.5 kW para validar el analisis teórico y la viabilidad de la propuesta. | es_ES |
dc.description.sponsorship | El presente trabajo fue soportado por la Secretaría de Ciencia y Técnica de la Universidad Nacional de Río Cuarto (SeCyT, UNRC), el FONCyT de la Agencia Nacional de Promoción Científica y Tecnológica, la Red MEIHAPER CYTED y la Universidad Nacional de Rafaela (UNRaf). | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.relation.ispartof | Revista Iberoamericana de Automática e Informática industrial | es_ES |
dc.rights | Reconocimiento - No comercial - Compartir igual (by-nc-sa) | es_ES |
dc.subject | Three-Phase Dual Active Bridges Converter | es_ES |
dc.subject | Power electronics systems | es_ES |
dc.subject | Modeling and simulation | es_ES |
dc.subject | Detection and diagnosis | es_ES |
dc.subject | Convertidor CC-CC bidireccional | es_ES |
dc.subject | Sistemas electrónicos de potencia | es_ES |
dc.subject | Modelado y simulación | es_ES |
dc.subject | Detección y diagnóstico | es_ES |
dc.title | Esquema tolerante a fallas de transistores del lado de carga aplicado a convertidores CC-CC con puentes duales activos trifásicos | es_ES |
dc.title.alternative | Fault-Tolerant Scheme of Load-Side Transistors Applied to Three-Phase Dual Active Bridge DC-DC Converters | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.4995/riai.2022.15408 | |
dc.rights.accessRights | Abierto | es_ES |
dc.description.bibliographicCitation | Ochoa Sosa, JE.; Núñez, R.; Oggier, GE.; Oggier, GG.; García, G. (2022). Esquema tolerante a fallas de transistores del lado de carga aplicado a convertidores CC-CC con puentes duales activos trifásicos. Revista Iberoamericana de Automática e Informática industrial. 19(2):186-198. https://doi.org/10.4995/riai.2022.15408 | es_ES |
dc.description.accrualMethod | OJS | es_ES |
dc.relation.publisherversion | https://doi.org/10.4995/riai.2022.15408 | es_ES |
dc.description.upvformatpinicio | 186 | es_ES |
dc.description.upvformatpfin | 198 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 19 | es_ES |
dc.description.issue | 2 | es_ES |
dc.identifier.eissn | 1697-7920 | |
dc.relation.pasarela | OJS\15408 | es_ES |
dc.contributor.funder | Universidad Nacional de Río Cuarto | es_ES |
dc.contributor.funder | Agencia Nacional de Promoción Científica y Tecnológica, Argentina | es_ES |
dc.contributor.funder | Universidad Nacional de Rafaela | es_ES |
dc.description.references | Airabella, AM, Oggier, GG, Piris-Botalla, LE, Falco, CA, García, GO, 2016. Semi-conductors faults analysis in dual active bridge dc-dc converter. IET Power Electron. 9 (6), 1103-1110. https://doi.org/10.1049/iet-pel.2015.0299 | es_ES |
dc.description.references | Asgari, H., Heidari, M., Adib, E., 2019. Soft-switching isolated dual active bridge bidirectional dc-dc converter with simple structure. En: 2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC). págs. 707-712. https://doi.org/10.1109/PEDSTC.2019.8697703 | es_ES |
dc.description.references | Bento, F., Cardoso, AJM, 2018. A comprehensive survey on fault diagnosis and fault tolerance of dc-dc converters. Revista China de Ingeniería Eléctrica 4 (3), 1-12.https://doi.org/10.23919/CJEE.2018.8471284 | es_ES |
dc.description.references | Berger, M., Kocar, I., Fortin-Blanchette, H., Lavertu, C., 2020. Open-Phase Fault-Tolerant Operation of the Three-Phase Dual Active Bridge Converter. 35 (4), 3651-3662. https://doi.org/10.1109/TPEL.2019.2933487 | es_ES |
dc.description.references | Costa, LF, Buticchi, G., Liserre, M., 2018. A family of series-resonant dc-dc converter with fault-tolerance capability. IEEE Trans. on Ind. Appl. 54 (1), 335-344. https://doi.org/10.1109/TIA.2017.2757900 | es_ES |
dc.description.references | Costa, LF, Liserre, M., 2018. Failure analysis of the dc-dc converter: A comprehensive survey of faults and solutions for improving reliability. IEEE Power Electron. Mag. 5 (4), 42-51. https://doi.org/10.1109/MPEL.2018.2874345 | es_ES |
dc.description.references | Davoodi, A., Sadeghpour, D., Kashif, M., Albahrani, S. A., Atarodi, S. M., Zolghadri, M. R., 2018. A novel transistor open-circuit fault localization scheme for three-phase dual active bridge. Australasian Universities Power Engineering Conference, AUPEC 2018, 5-10. https://doi.org/10.1109/AUPEC.2018.8757901 | es_ES |
dc.description.references | De Doncker, RWAA, Divan, DM, Kheraluwala, MH, 1991. A three-phase soft-switched high-power-density dc/dc converter for high-power ap-plications. IEEE Trans. Ind. Appl. 27 (1), 63-73. https://doi.org/10.1109/28.67533 | es_ES |
dc.description.references | Haghbin, S., Blaabjerg, F., Bahman, A. S., 2019. Frozen leg operation of a three-phase dual active bridge converter. IEEE Trans. Power Electron. 34 (5), 4239-4248. https://doi.org/10.1109/TPEL.2018.2865092 | es_ES |
dc.description.references | Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., Baumann, E. D., 1992. Performance characterization of a high-power dual active bridge dc-to-dc converter. IEEE Trans. Ind. Appl. 28 (6), 1294-1301. https://doi.org/10.1109/28.175280 | es_ES |
dc.description.references | Kumar, G. K., Elangovan, D., 2020. Review on fault-diagnosis and fault tolerance for DC-DC converters. IET Power Electron. 13 (1), 1-13. https://doi.org/10.1049/iet-pel.2019.0672 | es_ES |
dc.description.references | Lu, Y., Wu, Q., Wang, Q., Liu, D., Xiao, L., 2018. Analysis of a novel zero voltage-switching bidirectional dc/dc converter for energy storage system. IEEE Trans. Power Electron. 33 (4), 3169-3179. https://doi.org/10.1109/TPEL.2017.2703949 | es_ES |
dc.description.references | M. Liserre, G. Buticchi, L. Costa, M. Andresen, 2017. "Spannungswandler, Verfahren zu dessen Betrieb und puterprogramm," German Patent DE102017104138. | es_ES |
dc.description.references | Naayagi, R. T., Forsyth, A. J., Shuttleworth, R., 2012. High-power bidirectional dc-dc converter for aerospace applications. IEEE Trans. Power Electron. 27 (11), 4366-4379. https://doi.org/10.1109/TPEL.2012.2184771 | es_ES |
dc.description.references | Ochoa-Sosa, J. E., Núñez, R. O., Oggier, G. G., García, G. O., 2021. Open-Phase Fault-Tolerant Operation of the Three-Phase Dual Active Bridge Converter. IEEE Latin America Transactions 19 (4), 385-395. https://latamt.ieeer9.org/index.php/transactions/article/view/3442/684 https://doi.org/10.1109/TLA.2021.9447587 | es_ES |
dc.description.references | Pei, X., Nie, S., Chen, Y., Kang, Y., 2012. Open-circuit fault diagnosis and fault-tolerant strategies for full-bridge dc-dc converters. IEEE Trans. Power Electron. 27 (5), 2550-2565. https://doi.org/10.1109/TPEL.2011.2173589 | es_ES |
dc.description.references | Piris-Botalla, L., Oggier, G. G., Airabella, A. M., Garc'ıa, G. O., 2016. Extensión del Rango de Operación con Conmutación Suave de un Convertidor CC-CC Bidireccional de Tres Puertos. Revista Iberoamericana de Automática e Informática Industrial RIAI 13 (1), 127-134. https://doi.org/10.1016/j.riai.2015.04.007 | es_ES |
dc.description.references | Ribeiro, E., Cardoso, A. J. M., Boccaletti, C., 2013. Fault-tolerant strategy for a photovoltaic dc-dc converter. IEEE Trans. Power Electron. 28 (6), 3008-3018. https://doi.org/10.1109/TPEL.2012.2226059 | es_ES |
dc.description.references | Song, Y., Wang, B., 2013. Survey on reliability of power electronic systems. IEEE Trans. Power Electron. 28 (1), 591-604. https://doi.org/10.1109/TPEL.2012.2192503 | es_ES |
dc.description.references | Troviano, M., Botalla, L. P., Oggier, G., 2021. Estrategia de modulación para minimizar la potencia reactiva en el enlace de ca de convertidores cc-cc de tres puertos aislados. Revista Iberoamericana de Automática e Informática industrial. En prensa https://doi.org/10.4995/riai.2021.14612 | es_ES |
dc.description.references | Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., Krishnamoorthy, H. S., 2014. Survey on fault-tolerant techniques for power electronic converters. IEEE Trans. Power Electron. 29 (12), 6319-6331. https://doi.org/10.1109/TPEL.2014.2304561 | es_ES |