Subtractive imaging in Confocal Scanning Microscopy using a CCD camera as a detector

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Subtractive imaging in Confocal Scanning Microscopy using a CCD camera as a detector

Mostrar el registro completo del ítem

Sanchez-Ortiga, E.; Sheppard, C.; Saavedra, G.; Martinez-Corral, M.; Doblas, A.; Calatayud Calatayud, A. (2012). Subtractive imaging in Confocal Scanning Microscopy using a CCD camera as a detector. Optics Letters. 37(7):1280-1282. https://doi.org/10.1364/OL.37.001280

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/31362

Ficheros en el ítem

Metadatos del ítem

Título: Subtractive imaging in Confocal Scanning Microscopy using a CCD camera as a detector
Autor: Sanchez-Ortiga, E. Sheppard, C.J.R. Saavedra, G. Martinez-Corral, M. Doblas, A. Calatayud Calatayud, Arnau
Entidad UPV: Universitat Politècnica de València. Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica - Centre de Tecnologies Físiques: Acústica, Materials i Astrofísica
Fecha difusión:
Resumen:
[EN] We report a scheme for the detector system of confocal microscopes in which the pinhole and a large-area detector are substituted by a CCD camera. The numerical integration of the intensities acquired by the active ...[+]
Palabras clave: Microscopy , Confocal microscopy , Scanning microscopy
Derechos de uso: Cerrado
Fuente:
Optics Letters. (issn: 0146-9592 )
DOI: 10.1364/OL.37.001280
Editorial:
Optical Society of America
Versión del editor: http://dx.doi.org/10.1364/OL.37.001280
Código del Proyecto:
info:eu-repo/grantAgreement/MICINN//FIS2009-09135/ES/Desarrollo De Nuevos Dispositivos De Registro Y Visualizacion De Muestras 3D Con Resolucion Submicrometrica/
info:eu-repo/grantAgreement/GVA//PROMETEO09%2F2009%2F077/ES/Grupo de fibras ópticas y procesado de señal/
Agradecimientos:
This work was supported by the Plan Nacional I+D+I under grant FIS2009-9135 and also by Generalitat Valenciana under grant PROMETEO2009-077.
Tipo: Artículo

References

Sheppard, C. J. R., & Choudhury, A. (1977). Image Formation in the Scanning Microscope. Optica Acta: International Journal of Optics, 24(10), 1051-1073. doi:10.1080/713819421

Sheppard, C. J. R., & Wilson, T. (1978). Image Formation in Scanning Microscopes with Partially Coherent Source and Detector. Optica Acta: International Journal of Optics, 25(4), 315-325. doi:10.1080/713819784

Sheppard, C. J. R., & Cogswell, C. J. (1990). Confocal Microscopy with Detector Arrays. Journal of Modern Optics, 37(2), 267-279. doi:10.1080/09500349014550331 [+]
Sheppard, C. J. R., & Choudhury, A. (1977). Image Formation in the Scanning Microscope. Optica Acta: International Journal of Optics, 24(10), 1051-1073. doi:10.1080/713819421

Sheppard, C. J. R., & Wilson, T. (1978). Image Formation in Scanning Microscopes with Partially Coherent Source and Detector. Optica Acta: International Journal of Optics, 25(4), 315-325. doi:10.1080/713819784

Sheppard, C. J. R., & Cogswell, C. J. (1990). Confocal Microscopy with Detector Arrays. Journal of Modern Optics, 37(2), 267-279. doi:10.1080/09500349014550331

Pawley, J. B., Blouke, M. M., & Janesick, J. R. (1996). <title>CCDiode: an optimal detector for laser confocal microscopes</title>. Three-Dimensional Microscopy: Image Acquisition and Processing III. doi:10.1117/12.237490

Müller, C. B., & Enderlein, J. (2010). Image Scanning Microscopy. Physical Review Letters, 104(19). doi:10.1103/physrevlett.104.198101

Wilson, T., & Carlini, A. R. (1988). Effect of detector displacement in confocal imaging systems. Applied Optics, 27(18), 3791. doi:10.1364/ao.27.003791

Heintzmann, R., Sarafis, V., Munroe, P., Nailon, J., Hanley, Q. S., & Jovin, T. M. (2003). Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes. Micron, 34(6-7), 293-300. doi:10.1016/s0968-4328(03)00054-4

Boyer, G., & Sarafis, V. (2001). Two pinhole superresolution using spatial filters. Optik, 112(4), 177-179. doi:10.1078/0030-4026-00033

Martı́nez-Corral, M., Caballero, M. T., Ibáñez-López, C., & Sarafis, V. (2003). Optical sectioning by two-pinhole confocal fluorescence microscopy. Micron, 34(6-7), 313-318. doi:10.1016/s0968-4328(03)00057-x

Gu, M., & Sheppard, C. J. R. (1992). Confocal fluorescent microscopy with a finite-sized circular detector. Journal of the Optical Society of America A, 9(1), 151. doi:10.1364/josaa.9.000151

Wilson1, T., & Carlini, A. R. (1987). Size of the detector in confocal imaging systems. Optics Letters, 12(4), 227. doi:10.1364/ol.12.000227

[-]