- -

Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Alcaraz, Raúl es_ES
dc.contributor.author Hornero, Fernando es_ES
dc.contributor.author Rieta, J J es_ES
dc.date.accessioned 2014-11-05T15:04:07Z
dc.date.available 2014-11-05T15:04:07Z
dc.date.issued 2011-01
dc.identifier.issn 0967-3334
dc.identifier.uri http://hdl.handle.net/10251/43899
dc.description.abstract The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF. © 2011 Institute of Physics and Engineering in Medicine. es_ES
dc.description.sponsorship This work was supported by projects TEC2007-64884 and TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII2C09-0224-5983, PPII11-0194-8121 and PII1C09-0036-3237 from Junta de Comunidades de Castilla La Mancha. en_EN
dc.language Inglés es_ES
dc.publisher IOP Publishing: Hybrid Open Access es_ES
dc.relation.ispartof Physiological Measurement es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Atrial fibrillation es_ES
dc.subject Dominant atrial frequency es_ES
dc.subject Electrocardiogram es_ES
dc.subject Electrograms es_ES
dc.subject Fibrillatory wave potency es_ES
dc.subject Main atrial wave es_ES
dc.subject Organization es_ES
dc.subject Article es_ES
dc.subject Electrocardiography es_ES
dc.subject Entropy es_ES
dc.subject Heart atrium es_ES
dc.subject Heart atrium fibrillation es_ES
dc.subject Heart function test es_ES
dc.subject Human es_ES
dc.subject Instrumentation es_ES
dc.subject Methodology es_ES
dc.subject Pathophysiology es_ES
dc.subject Time es_ES
dc.subject Electrophysiologic Techniques, Cardiac es_ES
dc.subject Heart Atria es_ES
dc.subject Humans es_ES
dc.subject Time Factors es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1088/0967-3334/32/1/007
dc.relation.projectID info:eu-repo/grantAgreement/MEC//TEC2007-64884/ES/SINERGIA DE METODOS LINEALES Y NO LINEALES PARA EL ANALISIS, ESTRATIFICACION Y PREDICCION DEL COMPORTAMIENTO DE LA FIBRILACION AURICULAR/ / es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PII1C09-0036-3237/ES/Predicción De Riesgo De Muerte Súbita Tras Infarto De Miocardio Mediante Técnicas Avanzadas De Procesado Digital De Señal/ / es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PII2C09-0224-5983/ES/Aplicación De Metodologías No Lineales Para La Estimación Robusta Y No Invasiva De La Organización En Fibrilación Auricular/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//TEC2010-20633/ES/DESARROLLO Y APLICACION DE ESTIMADORES AVANZADOS DE ORGANIZACION PARA LA CLASIFICACION TERAPEUTICA Y EL SEGUIMIENTO DE PACIENTES CON FIBRILACION AURICULAR/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PPII11-0194-8121]/ES/PPII11-0194-8121]/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Alcaraz, R.; Hornero, F.; Rieta, JJ. (2011). Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms. Physiological Measurement. 32(1):99-114. doi:10.1088/0967-3334/32/1/007 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1088/0967-3334/32/1/007 es_ES
dc.description.upvformatpinicio 99 es_ES
dc.description.upvformatpfin 114 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 32 es_ES
dc.description.issue 1 es_ES
dc.relation.senia 216782
dc.contributor.funder Ministerio de Educación y Ciencia es_ES
dc.contributor.funder Junta de Comunidades de Castilla-La Mancha es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem