Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water

Mostrar el registro completo del ítem

Jimenez, N.; Romero García, V.; Picó Vila, R.; García-Raffi, LM.; Staliünas, K. (2015). Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water. Applied Physics Letters. 107(20). doi:10.1063/1.4935917

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/62369

Ficheros en el ítem

Metadatos del ítem

Título: Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water
Autor: Jimenez, Noe Romero García, Vicente Picó Vila, Rubén García-Raffi, L. M. Staliünas, Kestutis
Entidad UPV: Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres
Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada
Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada
Universitat Politècnica de València. Instituto Universitario de Matemática Pura y Aplicada - Institut Universitari de Matemàtica Pura i Aplicada
Fecha difusión:
Resumen:
We report the nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating immersed in water. In the linear regime, the system presents high focal gain (32 dB), with a narrow beam-width and intense side ...[+]
Palabras clave: Focusing , Grating , Ultrasound , Diffraction gratings , Medical imaging , Nonlinear acoustics , Nonlinear optics , Acoustical lenses
Derechos de uso: Reserva de todos los derechos
Fuente:
Applied Physics Letters. (issn: 0003-6951 ) (eissn: 1077-3118 )
DOI: 10.1063/1.4935917
Editorial:
American Institute of Physics (AIP)
Versión del editor: http://dx.doi.org/10.1063/1.4935917
Código del Proyecto:
info:eu-repo/grantAgreement/MICINN//FIS2011-29734-C02-01/ES/CONTROL DE LA DIFRACCION DE LA LUZ EN MEDIOS MODULADOS/ /
info:eu-repo/grantAgreement/UPV//PAID-2012-253/
info:eu-repo/grantAgreement/MICINN//FIS2011-29734-C02-02/ES/CONTROL DE LA DIFRACCION DEL SONIDO EN MEDIOS MODULADOS: FOCALIZACION, FILTRADO ESPACIAL Y OTROS EFECTOS DE CONFORMACION DE HACES TRAS LA TRANSMISION Y REFLEXION/
info:eu-repo/grantAgreement/MINECO//MTM2012-36740-C02-02/ES/OPERADORES MULTILINEALES, ESPACIOS DE FUNCIONES/ INTEGRABLES Y APLICACIONES./
Descripción: This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Applied Physics Letters 107, 204103 (2015); doi: 10.1063/1.4935917 and may be found at http://dx.doi.org/10.1063/1.4935917.
Agradecimientos:
The work was supported by Spanish Ministry of Science and Innovation and European Union FEDER through Projects FIS2011-29734-C02-01 and -02, MTM2012-36740c02-02, and PAID 2012/253.
Tipo: Artículo

References

Farnow, S. A., & Auld, B. A. (1974). Acoustic Fresnel zone plate transducers. Applied Physics Letters, 25(12), 681-682. doi:10.1063/1.1655359

Sleva, M. Z., Hunt, W. D., & Briggs, R. D. (1994). Focusing performance of epoxy‐ and air‐backed polyvinylidene fluoride Fresnel zone plates. The Journal of the Acoustical Society of America, 96(3), 1627-1633. doi:10.1121/1.410242

Wang, H., Xing, D., & Xiang, L. (2008). Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer. Journal of Physics D: Applied Physics, 41(9), 095111. doi:10.1088/0022-3727/41/9/095111 [+]
Farnow, S. A., & Auld, B. A. (1974). Acoustic Fresnel zone plate transducers. Applied Physics Letters, 25(12), 681-682. doi:10.1063/1.1655359

Sleva, M. Z., Hunt, W. D., & Briggs, R. D. (1994). Focusing performance of epoxy‐ and air‐backed polyvinylidene fluoride Fresnel zone plates. The Journal of the Acoustical Society of America, 96(3), 1627-1633. doi:10.1121/1.410242

Wang, H., Xing, D., & Xiang, L. (2008). Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer. Journal of Physics D: Applied Physics, 41(9), 095111. doi:10.1088/0022-3727/41/9/095111

Molerón, M., Serra-Garcia, M., & Daraio, C. (2014). Acoustic Fresnel lenses with extraordinary transmission. Applied Physics Letters, 105(11), 114109. doi:10.1063/1.4896276

Clement, G., Nomura, H., & Kamakura, T. (2015). Ultrasound field measurement using a binary lens. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 62(2), 350-359. doi:10.1109/tuffc.2014.006800

Jiménez, N., Romero-García, V., Picó, R., Cebrecos, A., Sánchez-Morcillo, V. J., Garcia-Raffi, L. M., … Staliunas, K. (2014). Acoustic Bessel-like beam formation by an axisymmetric grating. EPL (Europhysics Letters), 106(2), 24005. doi:10.1209/0295-5075/106/24005

Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998). Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. Ultrasound in Medicine & Biology, 24(9), 1419-1435. doi:10.1016/s0301-5629(98)00110-0

Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002). Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. Ultrasound in Medicine & Biology, 28(2), 227-235. doi:10.1016/s0301-5629(01)00499-9

Konofagou, E. E., & Hynynen, K. (2003). Localized harmonic motion imaging: theory, simulations and experiments. Ultrasound in Medicine & Biology, 29(10), 1405-1413. doi:10.1016/s0301-5629(03)00953-0

Duck, F. A. (2002). Nonlinear acoustics in diagnostic ultrasound. Ultrasound in Medicine & Biology, 28(1), 1-18. doi:10.1016/s0301-5629(01)00463-x

Bailey, M. R., Khokhlova, V. A., Sapozhnikov, O. A., Kargl, S. G., & Crum, L. A. (2003). Physical mechanisms of the therapeutic effect of ultrasound (a review). Acoustical Physics, 49(4), 369-388. doi:10.1134/1.1591291

M. A. Averkiou , D. N. Roundhill , and J. Powers , in IEEE Proceedings of the Ultrasonics Symposium ( IEEE, 1997), Vol. 2, pp. 1561–1566.

Nguyen, M. M., Shin, J., & Yen, J. (2014). Harmonic Imaging with Fresnel Beamforming in the Presence of Phase Aberration. Ultrasound in Medicine & Biology, 40(10), 2488-2498. doi:10.1016/j.ultrasmedbio.2014.03.030

Lu, J.-Y., & Greenleaf, J. F. (1990). Ultrasonic nondiffracting transducer for medical imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 37(5), 438-447. doi:10.1109/58.105250

N. Jiménez , “ Nonlinear acoustic waves in complex media,” Ph.D. thesis, Universitat Politècnica de València, 2015.

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem