- -

Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling

Mostrar el registro completo del ítem

Romero-Méndez, R.; Tobajas, P.; Burdío Pinilla, F.; González, A.; Navarro Gonzalo, A.; Grande, L.; Berjano, E. (2012). Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling. International Journal of Hyperthermia. 28(7):653-662. https://doi.org/10.3109/02656736.2012.711894

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/80515

Ficheros en el ítem

Metadatos del ítem

Título: Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling
Autor: Romero-Méndez, Ricardo Tobajas, Pilar Burdío Pinilla, Fernando González, Ana Navarro Gonzalo, Ana Grande, Luis Berjano, Enrique
Entidad UPV: Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Fecha difusión:
Resumen:
Purpose: The Cool-tip electrode is one of the most widely employed applicators in radiofrequency (RF) hepatic ablation. Previous research demonstrated that it is possible to enlarge coagulation volume when the single ...[+]
Palabras clave: Cool-tip electrode , Computer modelling , Hepatic ablation , Radiofrequency ablation , Saline infusion , Tumour ablation
Derechos de uso: Cerrado
Fuente:
International Journal of Hyperthermia. (issn: 0265-6736 )
DOI: 10.3109/02656736.2012.711894
Editorial:
Taylor & Francis
Versión del editor: http://dx.doi.org/10.3109/02656736.2012.711894
Código del Proyecto:
info:eu-repo/grantAgreement/MICINN//TEC2008-01369/ES/MODELOS COMPUTACIONALES E INVESTIGACION EXPERIMENTAL EN EL ESTUDIO DE TECNICAS QUIRURGICAS DE CALENTAMIENTO DE TEJIDOS BIOLOGICOS MEDIANTE CORRIENTES DE RADIOFRECUENCIA./
info:eu-repo/grantAgreement/MICINN//TEC2011-27133-C02-01/ES/MODELADO TEORICO Y EXPERIMENTACION PARA TECNICAS ABLATIVAS BASADAS EN ENERGIAS/
info:eu-repo/grantAgreement/CONACYT//CB-2007-84618/
Agradecimientos:
This work received financial support from the Spanish Plan Nacional de I_D_i del Ministerio de Ciencia e Innovacion, grants TEC2008-01369/TEC and TEC2011-27133-C02-01. The authors thank CONACyT (Mexico) for support from ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem