Mostrar el registro completo del ítem
Pineda-Sanchez, M.; Riera-Guasp, M.; Antonino-Daviu, J.; Roger-Folch, J.; Perez-Cruz, J.; Puche-Panadero, R. (2009). Instantaneous Frequency of the Left Sideband Harmonic During the Start-Up Transient: A New Method for Diagnosis of Broken Bars. IEEE Transactions on Industrial Electronics. 56(11):4557-4570. https://doi.org/10.1109/TIE.2009.2026211
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/93475
Título: | Instantaneous Frequency of the Left Sideband Harmonic During the Start-Up Transient: A New Method for Diagnosis of Broken Bars | |
Autor: | Roger-Folch, José | |
Entidad UPV: |
|
|
Fecha difusión: |
|
|
Resumen: |
[EN] In this paper, a new method for detecting the presence of broken rotor bars is presented. The proposed approach is valid for induction machines started at constant frequency and consists of extracting the instantaneous ...[+]
|
|
Palabras clave: |
|
|
Derechos de uso: | Cerrado | |
Fuente: |
|
|
DOI: |
|
|
Editorial: |
|
|
Versión del editor: | https://doi.org/10.1109/TIE.2009.2026211 | |
Código del Proyecto: |
|
|
Agradecimientos: |
This work was supported by the European Community’s Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 [Research Project “Power Plant Robustification based on fault Detection and Isolation (PRODI) algorithms”].[+]
|
|
Tipo: |
|