Mostrar el registro sencillo del ítem
dc.contributor.author | García Diego, Fernando Juan | es_ES |
dc.contributor.author | Scatigno, Claudia | es_ES |
dc.contributor.author | Merello, Paloma | es_ES |
dc.contributor.author | Bustamante, Eliseo | es_ES |
dc.coverage.spatial | east=12.29146957397461; north=41.7558185773151; name=00119 Roma, Província de Roma, Itàlia | |
dc.date.accessioned | 2018-02-05T10:12:11Z | |
dc.date.available | 2018-02-05T10:12:11Z | |
dc.date.issued | 2016-10-27 | |
dc.identifier.isbn | 9788490484555 | |
dc.identifier.uri | http://hdl.handle.net/10251/96603 | |
dc.description.abstract | [EN] The present study addresses the influences of wind flow structure, as an important factor responsible of material damage (erosion contributing) on “Casa di Diana” Mithraeum, a roman building (130 A.D.) sited on Ostia Antica (archaeological site, Rome – Italy), through the Computational Fluid Dynamics (CFD) simulations and direct measurements for its verification and validation (V&V). In this preliminary work, we present results relating to 3D reconstruction (geometry of the entire building) and the mesh importing on Fluent software. In general, the data check confirms, with ±10%, a good agreement (model) between the numerical solutions and direct measurements data by portable sensor. For this, the model proposed could be applied on similar cases, buildings characterised by different “boundary conditions”, to predict without direct measurements, the air movement in these ventilated spaces. | es_ES |
dc.description.abstract | [ES] El presente estudio aborda la influencia de la acción del viento en la estructura puesto que dicha acción es un factor relevante y responsable del daño material (contribuye en la erosión) del mítreo de la “Casa de Diana”, un edificio romano (130 A.C.) situado en Ostia Antica (sitio arqueológico, Roma, Italia), mediante las simulaciones de la dinámica de fluidos computacional y las mediciones de campo para su verificación y validación (V&V). En este trabajo preliminar, se presentan los resultados de un reconstrucción 3D (geometría del edificio entero) y del mallado importado al software Fluent. En general, la inspección de los datos confirma, con ±10%, un buen ajuste (modelo) de las soluciones numéricas y de las mediciones de campo adquiridas mediante un sensor portátil. Para ello, el modelo propuesto puede ser aplicado en casos similares, edificios caracterizados por diferentes condiciones de contorno, para predecir sin las mediciones de campo el movimiento del aire en estos espacios ventilados. | es_ES |
dc.format.extent | 4 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Editorial Universitat Politècnica de València | es_ES |
dc.relation.ispartof | 8th International congress on archaeology, computer graphics, cultural heritage and innovation | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Computational Fluid Dynamics (CFD) | es_ES |
dc.subject | Ventilation | es_ES |
dc.subject | Archaeological site | es_ES |
dc.subject | Preventive conservation | es_ES |
dc.subject | 3D reconstruction | es_ES |
dc.title | PRELIMINARY DATA OF CFD MODELING TO ASSESS THE VENTILATION IN AN ARCHAEOLOGICAL BUILDING | es_ES |
dc.title.alternative | MODELIZACIÓN MEDIANTE CFD DE PARA EVALUAR LA VENTILACIÓN EN UN EDIFICIO ARQUEOLÓGICO, DATOS PRELIMINARES. | es_ES |
dc.type | Capítulo de libro | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.identifier.doi | 10.4995/arqueologica8.2016.4191 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Centro de Investigación Acuicultura y Medio Ambiente - Centre d'Investigació Aqüicultura i Medi Ambient | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.description.bibliographicCitation | García Diego, FJ.; Scatigno, C.; Merello, P.; Bustamante, E. (2016). PRELIMINARY DATA OF CFD MODELING TO ASSESS THE VENTILATION IN AN ARCHAEOLOGICAL BUILDING. En 8th International congress on archaeology, computer graphics, cultural heritage and innovation. Editorial Universitat Politècnica de València. 504-507. https://doi.org/10.4995/arqueologica8.2016.4191 | es_ES |
dc.description.accrualMethod | OCS | es_ES |
dc.relation.conferencename | ARQUEOLÓGICA 2.0 - 8th International Congress on Archaeology, Computer Graphics, Cultural Heritage and Innovation | es_ES |
dc.relation.conferencedate | September 05-07,2016 | es_ES |
dc.relation.conferenceplace | Valencia, Spain | es_ES |
dc.relation.publisherversion | http://ocs.editorial.upv.es/index.php/arqueologica20/arqueologica8/paper/view/4191 | es_ES |
dc.description.upvformatpinicio | 504 | es_ES |
dc.description.upvformatpfin | 507 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.relation.pasarela | OCS\4191 | es_ES |