Gyftakis, KN.; Antonino-Daviu, J.; Garcia-Hernandez, R.; Mcculloch, MD.; Howey, DA.; Marques Cardoso, AJ. (2016). Comparative Experimental Investigation of Broken Bar Fault Detectability in Induction Motors. IEEE Transactions on Industry Applications. 52(2):1452-1459. doi:10.1109/TIA.2015.2505663
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/99175
Título: | Comparative Experimental Investigation of Broken Bar Fault Detectability in Induction Motors | |
Autor: | Gyftakis, Konstantinos N. Garcia-Hernandez, Raul McCulloch, Malcolm D. Howey, David A. Marques Cardoso, Antonio J. | |
Entidad UPV: |
|
|
Fecha difusión: |
|
|
Resumen: |
[EN] It has been shown in the past that the zero-sequence current spectrum can be reliably used to detect broken bar faults in induction motors. Previous work was carried out with extensive FEM analysis. Although it allows ...[+]
|
|
Palabras clave: |
|
|
Derechos de uso: | Reserva de todos los derechos | |
Fuente: |
|
|
DOI: |
|
|
Editorial: |
|
|
Versión del editor: | https://doi.org/10.1109/TIA.2015.2505663 | |
Código del Proyecto: |
|
|
Agradecimientos: |
|
|
Tipo: |
|