Sanza, F.; Holgado, M.; Ortega Higueruelo, FJ.; Casquel Del Campo, R.; López-Romero, D.; Bañuls Polo, MJ.; Laguna, MF.... (2011). Bio-Photonic Sensing Cells over transparent substrates for anti-gestrinone antibodies biosensing. Biosensors and Bioelectronics. 26:4842-4847. https://doi.org/10.1016/j.bios.2011.06.010
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/46093
Título:
|
Bio-Photonic Sensing Cells over transparent substrates for anti-gestrinone antibodies biosensing
|
Autor:
|
Sanza, F.J.
Holgado, M.
Ortega Higueruelo, Francisco José
Casquel Del Campo, Rafael
López-Romero, D.
Bañuls Polo, Mª José
Laguna, Mari Fe
Barrios, C.A.
Puchades Pla, Rosa
Maquieira Catala, Ángel
|
Entidad UPV:
|
Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic
Universitat Politècnica de València. Instituto Universitario de Tecnología Nanofotónica - Institut Universitari de Tecnologia Nanofotònica
Universitat Politècnica de València. Departamento de Química - Departament de Química
|
Fecha difusión:
|
|
Resumen:
|
[EN] In a previous work we introduced the term Bio-Photonic Sensing Cells (BICELLs), referred to periodic networks of nano-pillar suitable for biosensing when are vertically interrogated. In this article, we demonstrate ...[+]
[EN] In a previous work we introduced the term Bio-Photonic Sensing Cells (BICELLs), referred to periodic networks of nano-pillar suitable for biosensing when are vertically interrogated. In this article, we demonstrate the biosensing capabilities of a type of micrometric size BICELLs made of SU-8 nano-pillars fabricated over transparent substrates. We verify the biochips functionality comparing the theoretical simulations with the experimental results when are optically interrogated in transmission. We also demonstrate a sensitivity enhancement by reducing the pitch among nano-pillars from 800 to 700. nm. Thus, the Limit of Detection achievable in these types of BICELLs is in the order of 64. pg/mL for 700. nm in pitch among nano-pillars in comparison with 292. pg/mL for 800. nm in pitch when are interrogated by Fourier Transform Visible and Infrared Spectrometry. The experiments exhibited a good reproducibility with a relative standard deviation of 0.29% measured within 8 days for a specific concentration. Finally, BICELLs functionality was tested in real conditions with unpurified rabbit serum for detecting anti-gestrinone antibodies, demonstrating the high performance of this type of BICELLs to detect specific antibodies having immobilized the suitable bioreceptors onto the sensing surface. © 2011 Elsevier B.V.
[-]
|
Palabras clave:
|
Anti-gestrinone detection
,
Optical biosensing
,
SU-8 nano-pillar
,
Biophotonic sensing
,
Bioreceptors
,
Biosensing
,
Biosensing capability
,
Infrared spectrometry
,
Limit of detection
,
Optical bio-sensing
,
Relative standard deviations
,
Reproducibilities
,
Sensing surface
,
Sensitivity enhancements
,
Specific concentration
,
Theoretical simulation
,
Transparent substrate
,
Antibodies
,
Bioassay
,
Biochips
,
Fourier transforms
,
Infrared spectroscopy
,
Chemical detection
,
Gestrinone
,
Article
,
Bio Photonic Sensing Cell
,
Biochip
,
Biofilm
,
Biosensor
,
Comparative study
,
Controlled study
,
Electric field
,
Immunoassay
,
Process optimization
,
Reproducibility
,
Sensitivity analysis
,
Simulation
,
Thickness
,
Animals
,
Biosensing Techniques
,
Equipment Design
,
Nanostructures
,
Optics and Photonics
,
Polymers
,
Rabbits
,
Oryctolagus cuniculus
|
Derechos de uso:
|
Cerrado |
Fuente:
|
Biosensors and Bioelectronics. (issn:
0956-5663
)
|
DOI:
|
10.1016/j.bios.2011.06.010
|
Editorial:
|
Elsevier
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/MICINN//TEC2008-06574-C03-03/ES/DESARROLLO DE ESTRUCTURAS NANO-OPTO-FLUIDICAS/
...[+]
info:eu-repo/grantAgreement/MICINN//TEC2008-06574-C03-03/ES/DESARROLLO DE ESTRUCTURAS NANO-OPTO-FLUIDICAS/
info:eu-repo/grantAgreement/MICINN//TEC2008-06574-C03-02/ES/ESTRUCTURAS NANO-OPTO-FLUIDICAS PARA SENSADO BIOQUIMICO BASADO EN TECNICAS DE INTERROGACION OPTICA DE ALTA SENSIBILIDAD/
info:eu-repo/grantAgreement/UPM//CCG10-UPM%2FSEM-5096/
info:eu-repo/grantAgreement/MICINN//TEC2008-06574-C03-01/ES/ESTRUCTURAS NANO-OPTO-FLUIDICAS PARA SENSADO BIOQUIMICO BASADO EN TECNICAS DE INTERROGACION OPTICA DE ALTA SENSIBILIDAD/
info:eu-repo/grantAgreement/GVA//ACOMP%2F2010%2F009/
info:eu-repo/grantAgreement/GVA//PROMETEO%2F2010%2F008/ES/AYUDA PARA EL GRUPO SYM-IDM/
[-]
|
Agradecimientos:
|
This work is done within the support of the Spanish Ministry of Science and Innovation under project BIOPSIA (REF: TEC2008-06574). The authors thanks the Comunidad de Madrid and Universidad Politecncia de Madrid (Project ...[+]
This work is done within the support of the Spanish Ministry of Science and Innovation under project BIOPSIA (REF: TEC2008-06574). The authors thanks the Comunidad de Madrid and Universidad Politecncia de Madrid (Project BIO-VERSATIL, Ref CCG10-UPM/SEM-5096), Generalitat Valenciana (project ACOMP/2010/009 and PROMETEO 2010/008) and Dr Eva Brun for providing the rabbit serum containing polyclonal antibodies for gestrinone studies. F.J.O. is grateful to the Generalitat Valenciana for the postdoctoral grant included in the VALi + d 2010 Programme for Postdoctoral Researchers.
[-]
|
Tipo:
|
Artículo
|